ETEPON Digital Oscilloscope Kit with BNC-Clip Cable Probe (Assembled Finished Machine) EM001
ETEPON Digital Oscilloscope Kit with BNC-Clip Cable Probe (Assembled Finished Machine) EM001
oscilloscope 2.4” Advanced Features No need do assembly or soldering work Extended both in width and height Easily measuring Sensitivity extended Hand-held Detailed instruction Easily capture instantaneous wave forms using the Auto/Normal/Single Trigger mode. Adapter Added Version Thanks for some customers' advice, we have updated this oscilloscope and added a suitable adapter for it. ETEPON EM001 Digital Oscilloscope Advanced Assembled Finished Machine ETEPON EM001 digital oscilloscope kit 2.4” TFT is an assembled finished machine which can be used directly. Unlike DIY oscilloscope kit, you don’t need to do assembly or soldering work before using, which will avoid some problem caused on soldering or assembling process and save your time. Detailed Operation instructions, troubleshooting guide and schematic are also provided. Read more Pofessional Assembled Display and MCU are mounted on the same board (mainboard) to avoid using inter-board pin-headers. Analog channel is placed on a separated board which contains most user install parts, so the analog and digital circuits can be better separated. Sensitivity Extended The sensitivity of the EM001 has been extended both in width and height, which is wider and wider than the others. It reaches 5mV / div - 20V / div, while others is only 10mV / div - 5v / div. Hand-Held This updated digital oscilloscope can be hand-held, while the others can only be used by placing it on the desktop. Read more Measuring Easily Using the Auto/Normal/Single Trigger mode,it is easy to capture instantaneous waveform. Rotary Encoder It has been added the rotary encoder, makes parameter adjustment quicker and easier. Hold Function You can freeze waveform display at any time.And with waveform storage function you will not lose the waveform after power off. Read more ETEPON EM001 oscilloscope Number of Channel 1 Analog Bandwidth 0 - 200KHz Sensitivity 5mV/Div - 20V/Div Sensitivity error < 5% Resolution 12-bit Input Impedance 1M ohm Maximum Input voltage 50Vpk Coupling DC, AC, GND Trigger Modes Auto, Normal, Single Trigger Types Rising/falling edge Trigger Position 1/2 of buffer size fixed Display 2.4 inch color TFT LCD with 320 x 240 resolution Power Supply 9V DC (8 - 10V acceptable) Dimension 115mm X 75mm X 22mm Weight 100 gram Kindly Note 1. This oscilloscope runs on 9V power adapter. The power supply voltage must not exceed 10V. Otherwise it is possible to burn out the machine. 9v dc power supply should be center positive. 2. The kit contains a power adapter.If you have 9V power adapter at home, you can choose the one without adapter. ◕‿◕ If you have any question or meet any problem on using this oscilloscope, please feel free to contact with us! Read more Answers for Frequently Asked Questions to help you: Q1, Display white screen? A1: Power supply voltage must be in the range of 8 - 10V.; Confirm signal input within range of equipment parameters. Q2,trigger level not center trigger level? A2: Hold down [TRIGGER] button for about 3 seconds. This will set the trigger level to the medium value of signal amplitude. Q3: Why my voltage numbers are incorrect? A3: There are two possible causes for wrong voltage display. 1 ) The reference point has not been calibrated, and 2 ) the gain of analog channel is incorrect. For 1 ) you just need to perform VPos alignment as instructed in the manual (it is strongly suggested to do factory default restore before VPos alignment to make sure all parameters are valid). For 2 ) please refer to the Troubleshooting section below to find out possible causes in analog channel. Q4: Can I use DSO Shell to measure high voltages like AC 220V ? A4: This oscilloscope was designed for low voltage measurement. The maximum input voltage was specified as 50Vpk (peak value). So it can not be used to directly measure any voltage higher than 50V. Otherwise that could damage the device or even cause body injury. But if attenuator is used it is possible to use oscilloscope to measure voltages higher than 50V. Using a standard probe at 10X setting, for example, it can take voltage up to 400V. However users need to fully understand the potential risk before doing so and will do at his/her own risk. strongly discourages users to use it for measurements at voltages higher than specified. Seller will assume no responsibility for any damages, losses, or body injuries caused by using DSO Shell to measure voltages higher than specification. Q5: Why does the encoder knob rotate trigger level up and down without change? A5: The encoder knob of the equipment needs to be fine-tuned in design, so it needs to be adjusted slowly to work. When the speed is too fast, the device will be considered invalid. For more question, welcome to ask anytime!
Product Features
- ASSEMBLED FINISHED: ETEPOPN EM001 digital DIY oscilloscope kit with case is an assembled finished machine No soldering/assembly work needs It can be used directly to avoid assembling /welding process problems and greatly save your time
- UPGRADED VERSION: The sensitivity of the EM001 has been extended both in width and height which is wider and higher than the others It reaches 5mV/div - 20V/div while the others is only 10mV/div - 5v/div
- HAND-HELD: This updated digital oscilloscope can be hand-held while the others can only be used by placing it on the desktop
- ROTARY ENCODER: It has been added the rotary encoder makes parameter adjustment more quicker and easier
- WHAT YOU GET: You will get a assembled oscilloscope and BNC-clip cable Detailed Operation instructions troubleshooting guide and schematic are also provided