{"id":7086675951796,"title":"Rigol PVP2150 Standard\/Passive Oscilloscope Probes","handle":"rigol-pvp2150-standard-passive-oscilloscope-probes","description":"\u003ch3\u003eRigol PVP2150 Standard\/Passive Oscilloscope Probes\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eRigol PVP2150 - Passive Probe PVP2150: 1X\/35MHz, 10X\/150MHz, one\/two Probes\nKit 10X or 1X Switchable 10 pF to 25 pF Compensation Range 1X: 1MO +-1% input\nresistance 50 pF +-20 pF input capacitance 150 VRMS CAT II max. rated input\nvoltageBefore taking any measurement using a probe, first check the frequency\ncompensation of the probe and adjust it to match the oscilloscope used.\nGenerally, the oscilloscope provides a calibration signal output terminal at\nthe front panel. Connect the probe (set the probe attenuation to 10X) to the\nsignal output terminal to display a square waveform on the oscilloscope.Insert\nthe adjustment tool into the compensation adjustment hole at the probe head\nand rotate it clockwise\/counterclockwise until the properly compensated square\nwaveform is displayed (flat-top square waveform).Frequency Compensations\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003e150 MHz Passive Probe with 1x:10x selector. With bandwidth of 35 MHz in 1x mode\u003c\/li\u003e\n \u003cli\u003ePVP2150: 1X\/35MHz, 10X\/150MHz, one\/two Probes Kit\u003c\/li\u003e\n \u003cli\u003e10X or 1X Switchable\u003c\/li\u003e\n \u003cli\u003e10 pF to 25 pF Compensation Range\u003c\/li\u003e\n \u003cli\u003e1X: 1M +-1% input resistance 50 pF +-20 pF input capacitance 150 VRMS CAT II max. rated input voltage\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-03-19T03:53:32+11:00","created_at":"2022-03-19T03:53:32+11:00","vendor":"Rigol","type":"Oscilloscope Probes","tags":["auspowers_batchone"],"price":20900,"price_min":20900,"price_max":20900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41335349477556,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B073T1FQD4","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Rigol PVP2150 Standard\/Passive Oscilloscope Probes","public_title":null,"options":["Default Title"],"price":20900,"weight":61,"compare_at_price":null,"inventory_management":null,"barcode":"993269711186","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B073T1FQD4.jpg?v=1648579895"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B073T1FQD4.jpg?v=1648579895","options":["Title"],"media":[{"alt":"[Australia - AusPower] - Rigol PVP2150 Standard\/Passive Oscilloscope Probes ","id":25351570292916,"position":1,"preview_image":{"aspect_ratio":0.518,"height":500,"width":259,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B073T1FQD4.jpg?v=1648579895"},"aspect_ratio":0.518,"height":500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B073T1FQD4.jpg?v=1648579895","width":259}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eRigol PVP2150 Standard\/Passive Oscilloscope Probes\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eRigol PVP2150 - Passive Probe PVP2150: 1X\/35MHz, 10X\/150MHz, one\/two Probes\nKit 10X or 1X Switchable 10 pF to 25 pF Compensation Range 1X: 1MO +-1% input\nresistance 50 pF +-20 pF input capacitance 150 VRMS CAT II max. rated input\nvoltageBefore taking any measurement using a probe, first check the frequency\ncompensation of the probe and adjust it to match the oscilloscope used.\nGenerally, the oscilloscope provides a calibration signal output terminal at\nthe front panel. Connect the probe (set the probe attenuation to 10X) to the\nsignal output terminal to display a square waveform on the oscilloscope.Insert\nthe adjustment tool into the compensation adjustment hole at the probe head\nand rotate it clockwise\/counterclockwise until the properly compensated square\nwaveform is displayed (flat-top square waveform).Frequency Compensations\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003e150 MHz Passive Probe with 1x:10x selector. With bandwidth of 35 MHz in 1x mode\u003c\/li\u003e\n \u003cli\u003ePVP2150: 1X\/35MHz, 10X\/150MHz, one\/two Probes Kit\u003c\/li\u003e\n \u003cli\u003e10X or 1X Switchable\u003c\/li\u003e\n \u003cli\u003e10 pF to 25 pF Compensation Range\u003c\/li\u003e\n \u003cli\u003e1X: 1M +-1% input resistance 50 pF +-20 pF input capacitance 150 VRMS CAT II max. rated input voltage\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

Rigol PVP2150 Standard/Passive Oscilloscope Probes

In Stock. Leaves warehouse within 2 - 3 business days

$209.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Rigol PVP2150 Standard/Passive Oscilloscope Probes

Rigol PVP2150 - Passive Probe PVP2150: 1X/35MHz, 10X/150MHz, one/two Probes Kit 10X or 1X Switchable 10 pF to 25 pF Compensation Range 1X: 1MO +-1% input resistance 50 pF +-20 pF input capacitance 150 VRMS CAT II max. rated input voltageBefore taking any measurement using a probe, first check the frequency compensation of the probe and adjust it to match the oscilloscope used. Generally, the oscilloscope provides a calibration signal output terminal at the front panel. Connect the probe (set the probe attenuation to 10X) to the signal output terminal to display a square waveform on the oscilloscope.Insert the adjustment tool into the compensation adjustment hole at the probe head and rotate it clockwise/counterclockwise until the properly compensated square waveform is displayed (flat-top square waveform).Frequency Compensations

Product Features

  • 150 MHz Passive Probe with 1x:10x selector. With bandwidth of 35 MHz in 1x mode
  • PVP2150: 1X/35MHz, 10X/150MHz, one/two Probes Kit
  • 10X or 1X Switchable
  • 10 pF to 25 pF Compensation Range
  • 1X: 1M +-1% input resistance 50 pF +-20 pF input capacitance 150 VRMS CAT II max. rated input voltage

Related Products