{"id":7861673787572,"title":"Siemens 3RV1021-1CA10 Manual Starter and Enclosure, Open Type, 1.8-2.5 FLA Adjustment Range","handle":"siemens-3rv1021-1ca10-manual-starter-and-enclosure-open-type-1-8-2-5-fla-adjustment-range","description":"\u003ch3\u003eSiemens 3RV1021-1CA10 Manual Starter and Enclosure, Open Type, 1.8-2.5 FLA Adjustment Range\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eClass 11 across the line manual starters and switches provide control for\nmachinery where remote start stop control is not required.. Class 11 - 3RV\nmanual starters are used for single and poly-phase motors up to 20HP @ 575V.\nStarters have bimetallic heater elements to provide class 10 overcurrent\nprotection. Each starter has a fourth bimetallic strip that reacts only to the\nambient temperature inside the control panel. This ambient compensation helps\nprevent the starter from nuisance tripping when the panel temperature is\nhigher than the ambient temperature of the motor.. A built-in differential\ntrip bar causes the starter to trip faster on a phase loss condition to help\nreduce motor damage.. Magnetic trip elements in each starter take the device\noff line when it senses current of 13 times the maximum FLA dial setting..\nClass 11 - 3RV switches provide control for inherently protected motors.\nTypical applications include metal and woodworking machinery, grinders, power\nsaws, conveyors, fans, pumps, blowers, textile and packaging machinery, and\npaper cutters.. Class 11 - 3RV manual starters can be used as Type E self-\nprotected manual combination starters (up to 22 amps) per UL508 or as\ncomponents in Group Installation per NEC 430.53. When using the Class 11 - 3RV\nas a manual combination starter upstream protection is not required.. Class 11\n- 3RV controllers are available with low voltage protection which will\nautomatically open the power poles when the voltage drops or the power is\ninterrupted.. Controllers with the LVP option provide the OSHA requirements\nfor protecting personnel from potential injury caused by the automatic start-\nup of machinery following a voltage drop or power interruption when low\nvoltage protection is specified.. Class 11 - 3RV is available as Open style,\nor in NEMA 1, NEMA 7 \u0026amp; 9 or NEMA 7 \u0026amp; 9 \/ 3 \u0026amp; 4 enclosures.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eON\/OFF rotary handle with lockout and visible trip indication.\u003c\/li\u003e\n \u003cli\u003eAdjustment dial for setting to motor FLA.\u003c\/li\u003e\n \u003cli\u003eClass 10 overload trip characteristics.\u003c\/li\u003e\n \u003cli\u003eShort circuit trip at 12 times the maximum setting of the FLA adjustment dial.\u003c\/li\u003e\n \u003cli\u003eShort circuit current rating\u003c\/li\u003e\n \u003c\/ul\u003e","published_at":"2024-10-14T15:51:04+11:00","created_at":"2024-10-14T03:52:06+11:00","vendor":"SIEMENS","type":"Motor Starters","tags":["industrial_Aug2024_update"],"price":30800,"price_min":30800,"price_max":30800,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":43650287796404,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B004YXVFO4","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Siemens 3RV1021-1CA10 Manual Starter and Enclosure, Open Type, 1.8-2.5 FLA Adjustment Range","public_title":null,"options":["Default Title"],"price":30800,"weight":227,"compare_at_price":null,"inventory_management":"shopify","barcode":"754554409207","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/auspowers.com\/cdn\/shop\/files\/B004YXVFO4.jpg?v=1728890099"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/files\/B004YXVFO4.jpg?v=1728890099","options":["Title"],"media":[{"alt":"[Australia - AusPower] - Siemens 3RV1021-1CA10 Manual Starter and Enclosure, Open Type, 1.8-2.5 FLA Adjustment Range ","id":30859778982068,"position":1,"preview_image":{"aspect_ratio":0.726,"height":1959,"width":1422,"src":"\/\/auspowers.com\/cdn\/shop\/files\/B004YXVFO4.jpg?v=1728890099"},"aspect_ratio":0.726,"height":1959,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/B004YXVFO4.jpg?v=1728890099","width":1422}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eSiemens 3RV1021-1CA10 Manual Starter and Enclosure, Open Type, 1.8-2.5 FLA Adjustment Range\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eClass 11 across the line manual starters and switches provide control for\nmachinery where remote start stop control is not required.. Class 11 - 3RV\nmanual starters are used for single and poly-phase motors up to 20HP @ 575V.\nStarters have bimetallic heater elements to provide class 10 overcurrent\nprotection. Each starter has a fourth bimetallic strip that reacts only to the\nambient temperature inside the control panel. This ambient compensation helps\nprevent the starter from nuisance tripping when the panel temperature is\nhigher than the ambient temperature of the motor.. A built-in differential\ntrip bar causes the starter to trip faster on a phase loss condition to help\nreduce motor damage.. Magnetic trip elements in each starter take the device\noff line when it senses current of 13 times the maximum FLA dial setting..\nClass 11 - 3RV switches provide control for inherently protected motors.\nTypical applications include metal and woodworking machinery, grinders, power\nsaws, conveyors, fans, pumps, blowers, textile and packaging machinery, and\npaper cutters.. Class 11 - 3RV manual starters can be used as Type E self-\nprotected manual combination starters (up to 22 amps) per UL508 or as\ncomponents in Group Installation per NEC 430.53. When using the Class 11 - 3RV\nas a manual combination starter upstream protection is not required.. Class 11\n- 3RV controllers are available with low voltage protection which will\nautomatically open the power poles when the voltage drops or the power is\ninterrupted.. Controllers with the LVP option provide the OSHA requirements\nfor protecting personnel from potential injury caused by the automatic start-\nup of machinery following a voltage drop or power interruption when low\nvoltage protection is specified.. Class 11 - 3RV is available as Open style,\nor in NEMA 1, NEMA 7 \u0026amp; 9 or NEMA 7 \u0026amp; 9 \/ 3 \u0026amp; 4 enclosures.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eON\/OFF rotary handle with lockout and visible trip indication.\u003c\/li\u003e\n \u003cli\u003eAdjustment dial for setting to motor FLA.\u003c\/li\u003e\n \u003cli\u003eClass 10 overload trip characteristics.\u003c\/li\u003e\n \u003cli\u003eShort circuit trip at 12 times the maximum setting of the FLA adjustment dial.\u003c\/li\u003e\n \u003cli\u003eShort circuit current rating\u003c\/li\u003e\n \u003c\/ul\u003e"}

Siemens 3RV1021-1CA10 Manual Starter and Enclosure, Open Type, 1.8-2.5 FLA Adjustment Range

In Stock. Leaves warehouse within 2 - 3 business days

$308.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Siemens 3RV1021-1CA10 Manual Starter and Enclosure, Open Type, 1.8-2.5 FLA Adjustment Range

Class 11 across the line manual starters and switches provide control for machinery where remote start stop control is not required.. Class 11 - 3RV manual starters are used for single and poly-phase motors up to 20HP @ 575V. Starters have bimetallic heater elements to provide class 10 overcurrent protection. Each starter has a fourth bimetallic strip that reacts only to the ambient temperature inside the control panel. This ambient compensation helps prevent the starter from nuisance tripping when the panel temperature is higher than the ambient temperature of the motor.. A built-in differential trip bar causes the starter to trip faster on a phase loss condition to help reduce motor damage.. Magnetic trip elements in each starter take the device off line when it senses current of 13 times the maximum FLA dial setting.. Class 11 - 3RV switches provide control for inherently protected motors. Typical applications include metal and woodworking machinery, grinders, power saws, conveyors, fans, pumps, blowers, textile and packaging machinery, and paper cutters.. Class 11 - 3RV manual starters can be used as Type E self- protected manual combination starters (up to 22 amps) per UL508 or as components in Group Installation per NEC 430.53. When using the Class 11 - 3RV as a manual combination starter upstream protection is not required.. Class 11 - 3RV controllers are available with low voltage protection which will automatically open the power poles when the voltage drops or the power is interrupted.. Controllers with the LVP option provide the OSHA requirements for protecting personnel from potential injury caused by the automatic start- up of machinery following a voltage drop or power interruption when low voltage protection is specified.. Class 11 - 3RV is available as Open style, or in NEMA 1, NEMA 7 & 9 or NEMA 7 & 9 / 3 & 4 enclosures.

Product Features

  • ON/OFF rotary handle with lockout and visible trip indication.
  • Adjustment dial for setting to motor FLA.
  • Class 10 overload trip characteristics.
  • Short circuit trip at 12 times the maximum setting of the FLA adjustment dial.
  • Short circuit current rating