{"id":7167422365876,"title":"Siemens 3RV1011-1GA10 Motor Starter Protector, Screw Connection, 3RV101 Frame Size, 4.5-6.3 FLA Adjustment Range, 82A Instantaneous Short Circuit Release, 65kA UL Short Circuit Breaking Capacity at 480V","handle":"siemens-3rv1011-1ga10-motor-starter-protector-screw-connection-3rv101-frame-size-4-5-6-3-fla-adjustment-range-82a-instantaneous-short-circuit-release-65ka-ul-short-circuit-breaking-capacity-at-480v","description":"\u003ch3\u003eSiemens 3RV1011-1GA10 Motor Starter Protector, Screw Connection, 3RV101 Frame Size, 4.5-6.3 FLA Adjustment Range, 82A Instantaneous Short Circuit Release, 65kA UL Short Circuit Breaking Capacity at 480V\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eThe 3RV101 MSP’s, can be used as components in Group Installation per NEC\n430-53(C) to turn motors on and off. Each device has built-in heater elements\nthat provide overload protection and magnetic trip elements to protect the\nmotor. When the 3RV101 is used as a component in Group Installation, multiple\nMSP’s can be installed below one circuit breaker to protect its own motor. A\ncontactor can be mounted to the MSP to provide a remotely operated starter.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eON\/OFF rocker mechanism with lockout.\u003c\/li\u003e\n \u003cli\u003eAdjustment dial for setting to motor FLA.\u003c\/li\u003e\n \u003cli\u003eClass 10 overload trip characteristics.\u003c\/li\u003e\n \u003cli\u003eShort circuit trip at 12 times the maximum setting of the FLA adjustment dial.\u003c\/li\u003e\n \u003cli\u003eShort circuit current rating\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-06-24T14:36:15+10:00","created_at":"2022-06-24T14:36:20+10:00","vendor":"Siemens","type":"Motor Starters","tags":["industrial"],"price":14100,"price_min":14100,"price_max":14100,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41604356243636,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B004YXUU18","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Siemens 3RV1011-1GA10 Motor Starter Protector, Screw Connection, 3RV101 Frame Size, 4.5-6.3 FLA Adjustment Range, 82A Instantaneous Short Circuit Release, 65kA UL Short Circuit Breaking Capacity at 480V","public_title":null,"options":["Default Title"],"price":14100,"weight":204,"compare_at_price":null,"inventory_management":null,"barcode":"0754554409009","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B004YXUU18.jpg?v=1656052620","\/\/auspowers.com\/cdn\/shop\/products\/61agNA6c8RL.jpg?v=1656045380","\/\/auspowers.com\/cdn\/shop\/products\/413M-ceST2L.jpg?v=1656045380","\/\/auspowers.com\/cdn\/shop\/products\/61YUN5NC3lL.jpg?v=1656045380","\/\/auspowers.com\/cdn\/shop\/products\/71u30dVKoCL.jpg?v=1656045380"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B004YXUU18.jpg?v=1656052620","options":["Title"],"media":[{"alt":"[Australia - AusPower] - Siemens 3RV1011-1GA10 Motor Starter Protector, Screw Connection, 3RV101 Frame Size, 4.5-6.3 FLA Adjustment Range, 82A Instantaneous Short Circuit Release, 65kA UL Short Circuit Breaking Capacity at 480V ","id":26268544860340,"position":1,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B004YXUU18.jpg?v=1656052620"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B004YXUU18.jpg?v=1656052620","width":1024},{"alt":"[Australia - AusPower] - Siemens 3RV1011-1GA10 Motor Starter Protector, Screw Connection, 3RV101 Frame Size, 4.5-6.3 FLA Adjustment Range, 82A Instantaneous Short Circuit Release, 65kA UL Short Circuit Breaking Capacity at 480V ","id":26267394408628,"position":2,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61agNA6c8RL.jpg?v=1656045380"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61agNA6c8RL.jpg?v=1656045380","width":1024},{"alt":"[Australia - AusPower] - Siemens 3RV1011-1GA10 Motor Starter Protector, Screw Connection, 3RV101 Frame Size, 4.5-6.3 FLA Adjustment Range, 82A Instantaneous Short Circuit Release, 65kA UL Short Circuit Breaking Capacity at 480V ","id":26267394441396,"position":3,"preview_image":{"aspect_ratio":0.75,"height":500,"width":375,"src":"\/\/auspowers.com\/cdn\/shop\/products\/413M-ceST2L.jpg?v=1656045380"},"aspect_ratio":0.75,"height":500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/413M-ceST2L.jpg?v=1656045380","width":375},{"alt":"[Australia - AusPower] - Siemens 3RV1011-1GA10 Motor Starter Protector, Screw Connection, 3RV101 Frame Size, 4.5-6.3 FLA Adjustment Range, 82A Instantaneous Short Circuit Release, 65kA UL Short Circuit Breaking Capacity at 480V ","id":26267394474164,"position":4,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61YUN5NC3lL.jpg?v=1656045380"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61YUN5NC3lL.jpg?v=1656045380","width":1024},{"alt":"[Australia - AusPower] - Siemens 3RV1011-1GA10 Motor Starter Protector, Screw Connection, 3RV101 Frame Size, 4.5-6.3 FLA Adjustment Range, 82A Instantaneous Short Circuit Release, 65kA UL Short Circuit Breaking Capacity at 480V ","id":26267394506932,"position":5,"preview_image":{"aspect_ratio":1.333,"height":768,"width":1024,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71u30dVKoCL.jpg?v=1656045380"},"aspect_ratio":1.333,"height":768,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71u30dVKoCL.jpg?v=1656045380","width":1024}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eSiemens 3RV1011-1GA10 Motor Starter Protector, Screw Connection, 3RV101 Frame Size, 4.5-6.3 FLA Adjustment Range, 82A Instantaneous Short Circuit Release, 65kA UL Short Circuit Breaking Capacity at 480V\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eThe 3RV101 MSP’s, can be used as components in Group Installation per NEC\n430-53(C) to turn motors on and off. Each device has built-in heater elements\nthat provide overload protection and magnetic trip elements to protect the\nmotor. When the 3RV101 is used as a component in Group Installation, multiple\nMSP’s can be installed below one circuit breaker to protect its own motor. A\ncontactor can be mounted to the MSP to provide a remotely operated starter.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eON\/OFF rocker mechanism with lockout.\u003c\/li\u003e\n \u003cli\u003eAdjustment dial for setting to motor FLA.\u003c\/li\u003e\n \u003cli\u003eClass 10 overload trip characteristics.\u003c\/li\u003e\n \u003cli\u003eShort circuit trip at 12 times the maximum setting of the FLA adjustment dial.\u003c\/li\u003e\n \u003cli\u003eShort circuit current rating\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

Siemens 3RV1011-1GA10 Motor Starter Protector, Screw Connection, 3RV101 Frame Size, 4.5-6.3 FLA Adjustment Range, 82A Instantaneous Short Circuit Release, 65kA UL Short Circuit Breaking Capacity at 480V

In Stock. Leaves warehouse within 2 - 3 business days

$141.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Siemens 3RV1011-1GA10 Motor Starter Protector, Screw Connection, 3RV101 Frame Size, 4.5-6.3 FLA Adjustment Range, 82A Instantaneous Short Circuit Release, 65kA UL Short Circuit Breaking Capacity at 480V

The 3RV101 MSP’s, can be used as components in Group Installation per NEC 430-53(C) to turn motors on and off. Each device has built-in heater elements that provide overload protection and magnetic trip elements to protect the motor. When the 3RV101 is used as a component in Group Installation, multiple MSP’s can be installed below one circuit breaker to protect its own motor. A contactor can be mounted to the MSP to provide a remotely operated starter.

Product Features

  • ON/OFF rocker mechanism with lockout.
  • Adjustment dial for setting to motor FLA.
  • Class 10 overload trip characteristics.
  • Short circuit trip at 12 times the maximum setting of the FLA adjustment dial.
  • Short circuit current rating