{"id":7991789224116,"title":"OWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes Probe\/200 MHz","handle":"owon-universal-oscilloscope-probe-kit-200-mhz-bnc-oscilloscope-clamp-button-head-damping-can-be-adjusted-by-1x-or-10x-slide-switch-for-oscilloscopes-probe-200-mhz","description":"\u003ch3\u003eOWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes\u003c\/h3\u003e\n\u003cp id=\"b\"\u003e\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003e200MHz Universal Oscilloscope Probe: The attenuation of the oscilloscope probe can be adjusted with a 1X or 10X slide switch, which is suitable for hds200 series oscilloscopes and equipped with the standard BNC connector.\u003c\/li\u003e\n \u003cli\u003eSafety Design The grounding crocodile clamp reliably grounds the probe stage for safe operation and correct signal reading. The tip of the removable hook is protected by a plastic housing that ensures the stability and reliability of the tip exposed at the test point.\u003c\/li\u003e\n \u003cli\u003eHigh Sensitivity Fully shielded welding BNC connector, less signal interference, pure copper plated gold pin, lower contact resistance and good contact performance.\u003c\/li\u003e\n \u003cli\u003eProduct specification: Maximum working input voltage 1x: \u0026lt;200V pk 10x: \u0026lt;600V pk, Length: 130cm 1.5cm, Net weight: \u0026lt;55g Please use within reasonable limits.\u003c\/li\u003e\n \u003cli\u003eAttention: When used with another instrument, the oscilloscope must have an input impedance of 1 M. The instrument must have a warm-up time of at least 20 minutes and be in an environment that does not exceed the limits.\u003c\/li\u003e\n \u003c\/ul\u003e","published_at":"2025-09-24T01:15:09+10:00","created_at":"2025-09-24T01:15:05+10:00","vendor":"OWON","type":"Oscilloscopes","tags":["industryDE_Sep2025"],"price":15400,"price_min":15400,"price_max":15400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":44048586735796,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"de-B0C2Z6K3P3","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"OWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes Probe\/200 MHz","public_title":null,"options":["Default Title"],"price":15400,"weight":81,"compare_at_price":null,"inventory_management":"shopify","barcode":"Owon-3200","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/auspowers.com\/cdn\/shop\/files\/de-B0C2Z6K3P3.jpg?v=1775768758","\/\/auspowers.com\/cdn\/shop\/files\/71suJDGFvDL.jpg?v=1758640508","\/\/auspowers.com\/cdn\/shop\/files\/61q0r3976-L.jpg?v=1758640508","\/\/auspowers.com\/cdn\/shop\/files\/61IeabuKKBL.jpg?v=1758640508","\/\/auspowers.com\/cdn\/shop\/files\/51kQ-ctnxRL.jpg?v=1758640508","\/\/auspowers.com\/cdn\/shop\/files\/8174-LtaaEL.jpg?v=1758640508","\/\/auspowers.com\/cdn\/shop\/files\/71IsrJTjPUL.jpg?v=1758640508"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/files\/de-B0C2Z6K3P3.jpg?v=1775768758","options":["Title"],"media":[{"alt":"[Australia - AusPower] - OWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes Probe\/200 MHz ","id":32189195419828,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1650,"width":1650,"src":"\/\/auspowers.com\/cdn\/shop\/files\/de-B0C2Z6K3P3.jpg?v=1775768758"},"aspect_ratio":1.0,"height":1650,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/de-B0C2Z6K3P3.jpg?v=1775768758","width":1650},{"alt":"[Australia - AusPower] - OWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes Probe\/200 MHz ","id":32189195452596,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1650,"width":1650,"src":"\/\/auspowers.com\/cdn\/shop\/files\/71suJDGFvDL.jpg?v=1758640508"},"aspect_ratio":1.0,"height":1650,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/71suJDGFvDL.jpg?v=1758640508","width":1650},{"alt":"[Australia - AusPower] - OWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes Probe\/200 MHz ","id":32189195485364,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1650,"width":1650,"src":"\/\/auspowers.com\/cdn\/shop\/files\/61q0r3976-L.jpg?v=1758640508"},"aspect_ratio":1.0,"height":1650,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/61q0r3976-L.jpg?v=1758640508","width":1650},{"alt":"[Australia - AusPower] - OWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes Probe\/200 MHz ","id":32189195518132,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1650,"width":1650,"src":"\/\/auspowers.com\/cdn\/shop\/files\/61IeabuKKBL.jpg?v=1758640508"},"aspect_ratio":1.0,"height":1650,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/61IeabuKKBL.jpg?v=1758640508","width":1650},{"alt":"[Australia - AusPower] - OWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes Probe\/200 MHz ","id":32189195550900,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1650,"width":1650,"src":"\/\/auspowers.com\/cdn\/shop\/files\/51kQ-ctnxRL.jpg?v=1758640508"},"aspect_ratio":1.0,"height":1650,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/51kQ-ctnxRL.jpg?v=1758640508","width":1650},{"alt":"[Australia - AusPower] - OWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes Probe\/200 MHz ","id":32189195583668,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1650,"width":1650,"src":"\/\/auspowers.com\/cdn\/shop\/files\/8174-LtaaEL.jpg?v=1758640508"},"aspect_ratio":1.0,"height":1650,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/8174-LtaaEL.jpg?v=1758640508","width":1650},{"alt":"[Australia - AusPower] - OWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes Probe\/200 MHz ","id":32189195616436,"position":7,"preview_image":{"aspect_ratio":1.0,"height":1650,"width":1650,"src":"\/\/auspowers.com\/cdn\/shop\/files\/71IsrJTjPUL.jpg?v=1758640508"},"aspect_ratio":1.0,"height":1650,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/71IsrJTjPUL.jpg?v=1758640508","width":1650}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eOWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes\u003c\/h3\u003e\n\u003cp id=\"b\"\u003e\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003e200MHz Universal Oscilloscope Probe: The attenuation of the oscilloscope probe can be adjusted with a 1X or 10X slide switch, which is suitable for hds200 series oscilloscopes and equipped with the standard BNC connector.\u003c\/li\u003e\n \u003cli\u003eSafety Design The grounding crocodile clamp reliably grounds the probe stage for safe operation and correct signal reading. The tip of the removable hook is protected by a plastic housing that ensures the stability and reliability of the tip exposed at the test point.\u003c\/li\u003e\n \u003cli\u003eHigh Sensitivity Fully shielded welding BNC connector, less signal interference, pure copper plated gold pin, lower contact resistance and good contact performance.\u003c\/li\u003e\n \u003cli\u003eProduct specification: Maximum working input voltage 1x: \u0026lt;200V pk 10x: \u0026lt;600V pk, Length: 130cm 1.5cm, Net weight: \u0026lt;55g Please use within reasonable limits.\u003c\/li\u003e\n \u003cli\u003eAttention: When used with another instrument, the oscilloscope must have an input impedance of 1 M. The instrument must have a warm-up time of at least 20 minutes and be in an environment that does not exceed the limits.\u003c\/li\u003e\n \u003c\/ul\u003e"}

OWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes Probe/200 MHz

In Stock. Leaves warehouse within 2 - 3 business days

$154.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

OWON Universal Oscilloscope Probe Kit, 200 MHz, BNC Oscilloscope Clamp Button Head Damping Can Be Adjusted by 1x or 10x Slide Switch for Oscilloscopes

Product Features

  • 200MHz Universal Oscilloscope Probe: The attenuation of the oscilloscope probe can be adjusted with a 1X or 10X slide switch, which is suitable for hds200 series oscilloscopes and equipped with the standard BNC connector.
  • Safety Design The grounding crocodile clamp reliably grounds the probe stage for safe operation and correct signal reading. The tip of the removable hook is protected by a plastic housing that ensures the stability and reliability of the tip exposed at the test point.
  • High Sensitivity Fully shielded welding BNC connector, less signal interference, pure copper plated gold pin, lower contact resistance and good contact performance.
  • Product specification: Maximum working input voltage 1x: <200V pk 10x: <600V pk, Length: 130cm 1.5cm, Net weight: <55g Please use within reasonable limits.
  • Attention: When used with another instrument, the oscilloscope must have an input impedance of 1 M. The instrument must have a warm-up time of at least 20 minutes and be in an environment that does not exceed the limits.