{"id":7164457517236,"title":"NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A)","handle":"nr2-93-thermal-overload-electric-overload-relay-motor-protection-thermal-overload-50-60hz-37-50a","description":"\u003ch3\u003eNR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A)\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eFeatures: 1. Suitable for using in power system with rated isolation voltage\nup to 690V, circuit of 50-60hz. 2. Can be used as overload protection of your\nlong term or indirect long term service motor. 3. Used for protecting the\nphase break when the electric motor is overload. 4. The relay has different\nmechanism and temperature compensation. 5. With phase break protection, manual\nand automatic reset, temperature compensation, trip indication, test button\nand stop button. Specification: Item Type: Thermal Overload Relay Power\nFrequency: 50-60hz Optional Rated Current:\n30-40A\/37-50A\/48-65A\/55-70A\/63-80A\/80-93A Rated Insulation Voltage: 690V Phase\nBreak Protection: Yes Manual and Automatic Reset: Yes Temperature\nCompensation: Available Tripping Instructions: Yes Test Button: Yes Stop\nButton: Yes Installation: Plug-in Auxiliary Contacts: 1NO + 1NC AC-15 220V\nRated Current A 2.73 AC-15 380V Rated Current A 1.58 DC-13 220V Rated Current\nA 0.2 Traverse Sectional Area: Main Loop4-35, Auxiliary Loop 0.5-2.5 Tripping\nLevel:10A Fuse Specification: 40aM 63gG Weight: Approx. 468g Package List: 1 \nThermal Overload Relay\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eWorking Range: Suitable for using in power system with rated isolation voltage up to 690V, circuit of 50-60hz\u003c\/li\u003e\n \u003cli\u003eLonger Service: Can be used as overload protection of your long term or indirect long term service motor\u003c\/li\u003e\n \u003cli\u003eProtection Function: Used for protecting the phase break when the electric motor is overload\u003c\/li\u003e\n \u003cli\u003eTemperature Compension: The relay has different mechanism and temperature compensation\u003c\/li\u003e\n \u003cli\u003eMultifunctions: With phase break protection, manual and automatic reset, temperature compensation, trip indication, test button and stop button\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-06-22T06:17:57+10:00","created_at":"2022-06-22T06:18:06+10:00","vendor":"Walfront","type":"Overload Relays","tags":["industrial"],"price":16100,"price_min":16100,"price_max":16100,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41597895737524,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B088RKBD8H","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A)","public_title":null,"options":["Default Title"],"price":16100,"weight":340,"compare_at_price":null,"inventory_management":null,"barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B088RKBD8H.jpg?v=1655882651","\/\/auspowers.com\/cdn\/shop\/products\/618TznUZrML.jpg?v=1655842686","\/\/auspowers.com\/cdn\/shop\/products\/71t2MOP6ubL.jpg?v=1655842686","\/\/auspowers.com\/cdn\/shop\/products\/61xegdIC-ZL.jpg?v=1655842686","\/\/auspowers.com\/cdn\/shop\/products\/51Hq2pNVl6L.jpg?v=1655842686","\/\/auspowers.com\/cdn\/shop\/products\/51SyTPBqV8S.jpg?v=1655842686","\/\/auspowers.com\/cdn\/shop\/products\/61aTpb9lqpL.jpg?v=1655842686","\/\/auspowers.com\/cdn\/shop\/products\/51gkvXrAmAL.jpg?v=1655842686","\/\/auspowers.com\/cdn\/shop\/products\/51wTO-y1PmL.jpg?v=1655842686"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B088RKBD8H.jpg?v=1655882651","options":["Title"],"media":[{"alt":"[Australia - AusPower] - NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A) ","id":26241991803060,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B088RKBD8H.jpg?v=1655882651"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B088RKBD8H.jpg?v=1655882651","width":1001},{"alt":"[Australia - AusPower] - NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A) ","id":26235216887988,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/618TznUZrML.jpg?v=1655842686"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/618TznUZrML.jpg?v=1655842686","width":1001},{"alt":"[Australia - AusPower] - NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A) ","id":26235216920756,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71t2MOP6ubL.jpg?v=1655842686"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71t2MOP6ubL.jpg?v=1655842686","width":1001},{"alt":"[Australia - AusPower] - NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A) ","id":26235216953524,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61xegdIC-ZL.jpg?v=1655842686"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61xegdIC-ZL.jpg?v=1655842686","width":1001},{"alt":"[Australia - AusPower] - NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A) ","id":26235216986292,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51Hq2pNVl6L.jpg?v=1655842686"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51Hq2pNVl6L.jpg?v=1655842686","width":1001},{"alt":"[Australia - AusPower] - NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A) ","id":26235217019060,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51SyTPBqV8S.jpg?v=1655842686"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51SyTPBqV8S.jpg?v=1655842686","width":1001},{"alt":"[Australia - AusPower] - NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A) ","id":26235217051828,"position":7,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61aTpb9lqpL.jpg?v=1655842686"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61aTpb9lqpL.jpg?v=1655842686","width":1001},{"alt":"[Australia - AusPower] - NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A) ","id":26235217084596,"position":8,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51gkvXrAmAL.jpg?v=1655842686"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51gkvXrAmAL.jpg?v=1655842686","width":1001},{"alt":"[Australia - AusPower] - NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A) ","id":26235217117364,"position":9,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51wTO-y1PmL.jpg?v=1655842686"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51wTO-y1PmL.jpg?v=1655842686","width":1001}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eNR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A)\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eFeatures: 1. Suitable for using in power system with rated isolation voltage\nup to 690V, circuit of 50-60hz. 2. Can be used as overload protection of your\nlong term or indirect long term service motor. 3. Used for protecting the\nphase break when the electric motor is overload. 4. The relay has different\nmechanism and temperature compensation. 5. With phase break protection, manual\nand automatic reset, temperature compensation, trip indication, test button\nand stop button. Specification: Item Type: Thermal Overload Relay Power\nFrequency: 50-60hz Optional Rated Current:\n30-40A\/37-50A\/48-65A\/55-70A\/63-80A\/80-93A Rated Insulation Voltage: 690V Phase\nBreak Protection: Yes Manual and Automatic Reset: Yes Temperature\nCompensation: Available Tripping Instructions: Yes Test Button: Yes Stop\nButton: Yes Installation: Plug-in Auxiliary Contacts: 1NO + 1NC AC-15 220V\nRated Current A 2.73 AC-15 380V Rated Current A 1.58 DC-13 220V Rated Current\nA 0.2 Traverse Sectional Area: Main Loop4-35, Auxiliary Loop 0.5-2.5 Tripping\nLevel:10A Fuse Specification: 40aM 63gG Weight: Approx. 468g Package List: 1 \nThermal Overload Relay\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eWorking Range: Suitable for using in power system with rated isolation voltage up to 690V, circuit of 50-60hz\u003c\/li\u003e\n \u003cli\u003eLonger Service: Can be used as overload protection of your long term or indirect long term service motor\u003c\/li\u003e\n \u003cli\u003eProtection Function: Used for protecting the phase break when the electric motor is overload\u003c\/li\u003e\n \u003cli\u003eTemperature Compension: The relay has different mechanism and temperature compensation\u003c\/li\u003e\n \u003cli\u003eMultifunctions: With phase break protection, manual and automatic reset, temperature compensation, trip indication, test button and stop button\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A)

In Stock. Leaves warehouse within 2 - 3 business days

$161.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

NR2-93 Thermal Overload Electric Overload Relay Motor Protection Thermal Overload 50-60hz (37-50A)

Features: 1. Suitable for using in power system with rated isolation voltage up to 690V, circuit of 50-60hz. 2. Can be used as overload protection of your long term or indirect long term service motor. 3. Used for protecting the phase break when the electric motor is overload. 4. The relay has different mechanism and temperature compensation. 5. With phase break protection, manual and automatic reset, temperature compensation, trip indication, test button and stop button. Specification: Item Type: Thermal Overload Relay Power Frequency: 50-60hz Optional Rated Current: 30-40A/37-50A/48-65A/55-70A/63-80A/80-93A Rated Insulation Voltage: 690V Phase Break Protection: Yes Manual and Automatic Reset: Yes Temperature Compensation: Available Tripping Instructions: Yes Test Button: Yes Stop Button: Yes Installation: Plug-in Auxiliary Contacts: 1NO + 1NC AC-15 220V Rated Current A 2.73 AC-15 380V Rated Current A 1.58 DC-13 220V Rated Current A 0.2 Traverse Sectional Area: Main Loop4-35, Auxiliary Loop 0.5-2.5 Tripping Level:10A Fuse Specification: 40aM 63gG Weight: Approx. 468g Package List: 1 Thermal Overload Relay

Product Features

  • Working Range: Suitable for using in power system with rated isolation voltage up to 690V, circuit of 50-60hz
  • Longer Service: Can be used as overload protection of your long term or indirect long term service motor
  • Protection Function: Used for protecting the phase break when the electric motor is overload
  • Temperature Compension: The relay has different mechanism and temperature compensation
  • Multifunctions: With phase break protection, manual and automatic reset, temperature compensation, trip indication, test button and stop button