{"id":7992071848116,"title":"CCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power","handle":"ccs811-carbon-monoxide-co-vocs-air-quality-numerical-gas-sensors-module-high-precision-power-digital-gas-sensor-with-extremely-low-power","description":"\u003ch3\u003eCCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power\u003c\/h3\u003e\n\u003cp id=\"b\"\u003e1\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eCCS811: CCS811 is an ultra-low digital gas sensor that integrates the CCS801 sensor and 8-bit MCU (with analog-digital converter (ADC)), to detect indoor air quality\u003c\/li\u003e\n \u003cli\u003eLow energy consumption: the sensor is characterised by a relatively low power consumption and can therefore also be used in battery-operated devices.\u003c\/li\u003e\n \u003cli\u003eHigh sensitivity: Intelligent algorithm calculates TVOC\/eCO2 values and outputs I2C. The signal can communicate directly with the microcontroller.\u003c\/li\u003e\n \u003cli\u003eUsed for: without host intervention, equivalent indicators of carbon dioxide content or total amount of volatile organic compounds can be provided.\u003c\/li\u003e\n \u003cli\u003eFeatures: Integrated with 8-bit MCU for calculating the first level algorithm, integrated with 12-bit ADC for sensor reading and digital conversion, I2C slave interface can be directly connected to the main control system for reset\/interrupt control.\u003c\/li\u003e\n \u003c\/ul\u003e","published_at":"2025-09-25T10:54:16+10:00","created_at":"2025-09-25T10:54:10+10:00","vendor":"GERUI","type":"Indoor Air Quality Meters","tags":["industryDE_Sep2025"],"price":14900,"price_min":14900,"price_max":14900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":44052044873908,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"de-B0DDT5QNKB","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"CCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power","public_title":null,"options":["Default Title"],"price":14900,"weight":10,"compare_at_price":null,"inventory_management":"shopify","barcode":"744243857754","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}],"images":["\/\/auspowers.com\/cdn\/shop\/files\/de-B0DDT5QNKB.jpg?v=1775770244","\/\/auspowers.com\/cdn\/shop\/files\/61hkVw3ybrL.jpg?v=1758761867","\/\/auspowers.com\/cdn\/shop\/files\/61MnDz1TNOL.jpg?v=1758761960","\/\/auspowers.com\/cdn\/shop\/files\/611IGnTqOlL.jpg?v=1758761946","\/\/auspowers.com\/cdn\/shop\/files\/51820XjiIML.jpg?v=1758761857","\/\/auspowers.com\/cdn\/shop\/files\/61hFXQfZWDL.jpg?v=1758761867"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/files\/de-B0DDT5QNKB.jpg?v=1775770244","options":["Title"],"media":[{"alt":"[Australia - AusPower] - CCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power ","id":32196442685620,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/auspowers.com\/cdn\/shop\/files\/de-B0DDT5QNKB.jpg?v=1775770244"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/de-B0DDT5QNKB.jpg?v=1775770244","width":1600},{"alt":"[Australia - AusPower] - CCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power ","id":32196442718388,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/auspowers.com\/cdn\/shop\/files\/61hkVw3ybrL.jpg?v=1758761867"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/61hkVw3ybrL.jpg?v=1758761867","width":1600},{"alt":"[Australia - AusPower] - CCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power ","id":32196442751156,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/auspowers.com\/cdn\/shop\/files\/61MnDz1TNOL.jpg?v=1758761960"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/61MnDz1TNOL.jpg?v=1758761960","width":1600},{"alt":"[Australia - AusPower] - CCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power ","id":32196442783924,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/auspowers.com\/cdn\/shop\/files\/611IGnTqOlL.jpg?v=1758761946"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/611IGnTqOlL.jpg?v=1758761946","width":1600},{"alt":"[Australia - AusPower] - CCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power ","id":32196442816692,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/auspowers.com\/cdn\/shop\/files\/51820XjiIML.jpg?v=1758761857"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/51820XjiIML.jpg?v=1758761857","width":1600},{"alt":"[Australia - AusPower] - CCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power ","id":32196442849460,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1600,"width":1600,"src":"\/\/auspowers.com\/cdn\/shop\/files\/61hFXQfZWDL.jpg?v=1758761867"},"aspect_ratio":1.0,"height":1600,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/files\/61hFXQfZWDL.jpg?v=1758761867","width":1600}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eCCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power\u003c\/h3\u003e\n\u003cp id=\"b\"\u003e1\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eCCS811: CCS811 is an ultra-low digital gas sensor that integrates the CCS801 sensor and 8-bit MCU (with analog-digital converter (ADC)), to detect indoor air quality\u003c\/li\u003e\n \u003cli\u003eLow energy consumption: the sensor is characterised by a relatively low power consumption and can therefore also be used in battery-operated devices.\u003c\/li\u003e\n \u003cli\u003eHigh sensitivity: Intelligent algorithm calculates TVOC\/eCO2 values and outputs I2C. The signal can communicate directly with the microcontroller.\u003c\/li\u003e\n \u003cli\u003eUsed for: without host intervention, equivalent indicators of carbon dioxide content or total amount of volatile organic compounds can be provided.\u003c\/li\u003e\n \u003cli\u003eFeatures: Integrated with 8-bit MCU for calculating the first level algorithm, integrated with 12-bit ADC for sensor reading and digital conversion, I2C slave interface can be directly connected to the main control system for reset\/interrupt control.\u003c\/li\u003e\n \u003c\/ul\u003e"}

CCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power

In Stock. Leaves warehouse within 2 - 3 business days

$149.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

CCS811 Carbon Monoxide CO VOCs Air Quality Numerical Gas Sensors Module High Precision Power Digital Gas Sensor with Extremely Low Power

1

Product Features

  • CCS811: CCS811 is an ultra-low digital gas sensor that integrates the CCS801 sensor and 8-bit MCU (with analog-digital converter (ADC)), to detect indoor air quality
  • Low energy consumption: the sensor is characterised by a relatively low power consumption and can therefore also be used in battery-operated devices.
  • High sensitivity: Intelligent algorithm calculates TVOC/eCO2 values and outputs I2C. The signal can communicate directly with the microcontroller.
  • Used for: without host intervention, equivalent indicators of carbon dioxide content or total amount of volatile organic compounds can be provided.
  • Features: Integrated with 8-bit MCU for calculating the first level algorithm, integrated with 12-bit ADC for sensor reading and digital conversion, I2C slave interface can be directly connected to the main control system for reset/interrupt control.