{"id":7169968373940,"title":"YYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module","handle":"yyb-5-12v-24v-forward-reverse-motor-control-board-two-relay-timing-cycle-module","description":"\u003ch3\u003eYYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eSpecification: The two-way pump controller has 6 common\nfunctions, and the functions can be set arbitrarily to meet more application\nneeds; it can control 2 way solenoid valves, water pumps, motors, light\nstrips, etc. Read more Key Settings Description: Power display \"----\" that\naccess to standby; Press the first time K1, the screen shows: P-1: K2 and K3\nadjustment mode Press the second time K1, the screen shows: A001: K2 and K3\nadjust the first time A, K4 adjust the decimal point (time unit) Press the\nthird time K1, the screen shows: B001: K2 and K3 adjust the second time B, K4\nadjust the decimal point (time unit) Press the fourth time K1, the screen\nshows: C001: K2 and K3 adjust the third time C, K4 adjust the decimal point\n(time unit) Press the fifth K1, display \"----\" that entered the standby state;\nFor example; need to set the mode: P - 2; time: A010 B005 C006: Indicating the\nsecond mode of operation; after the signal 1; relay 1 after 10 seconds to\nstart off; relay 2 to give the signal after delay 5 seconds after the start 1\nsecond automatically shut down Read more Model:YYB-5 Input voltage: DC\/ AC\n7V~27V Time range: 0.1 seconds to 999 minutes Weight: Approx.103g\/3.6oz Read\nmore Wiring port Description: 1. AC\/DC : Input 7V~27V 2. IN1: Signal input 1\n(negative trigger) 3. IN2: Signal input terminal 2 (negative trigger) 4. IN3:\nSignal input 3 (negative trigger) 5. NO: relay normally open interface, relay\npull before the suspension, after the connection with the COM shorted 6. COM:\nrelay common interface 7. NC: relay normally closed interface, the relay\nbefore the connection with the COM shorted, pull after the suspension Read\nmore Function list: P - 1: to signal 1, relay 1 pulls to A time automatically\nstops; to signal 2, relay 2 pulls to B time automatically stops; signal 3 is\nemergency stop reset signal P - 2: signal 1, relay 1 is pulled to A time\nautomatically stop; relay 2 from the signal to start delay B time after the\nsuction to C time automatically stop (this function time unit needs to be\nconsistent) P - 3: After power on, relay 1 pulls up to A time release, waiting\nfor C time, relay 2 pulls to B time release, waits for C time; relay 1,2 turns\nendless operation endless cycle (If the control motor is reversible can be\nunderstood as: the motor is running a period of time; stop for some time;\nautomatically reverse for some time; stop for some time; then automatically\nforward; P - 4: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stops\nand starts counting to A time relay 2 pull; to signal 3 (limit), relay 2 stops\nand starts timing To B time relay 1 pull; infinite loop (If the control motor\nis reversible can be understood as: press the start button 1; the motor is\nmoving to the limit 2 to stop for a period of time; automatically reverse to\nthe limit 3 to stop a period of time; then automatically forward; P - 5: to\nsignal 1, relay 1 pull; to signal 2 (limit), relay 1 stop and start timing to\nA time relay 2 pull; give signal 3 (limit), relay 2 stop; Signal 1; once again\n(If the control motor is reversible can be understood as: press the start\nbutton 1; the motor is moving to the limit 2 to stop for a period of time;\nautomatically reverse to the limit 3 stop; give the signal 1; P-6: to signal\n1, relay 1 pull; to signal 2 (limit), relay 1 stop; give signal 1, relay 2\npull; to signal 3 (limit), relay 2 stop; (If the control motor is reversible\ncan be understood as: press the start button 1; go to the limit 2 stop; press\nthe start button 1 again; reverse to the limit 3 stop; If the remote control\nfunction: remote control A key and B key to start the above function; C key\npress the relay 1 work (forward); then press the relay 1 to stop (stop); D key\npress the relay 2 work (reverse); Press once relay 2 to stop (stop); Read more\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003e6 KINDS OF FUNCTIONSThe module has 6 kinds of commonly used functions to meet the needs of more applications.\u003c\/li\u003e\n \u003cli\u003eWIDE APPLICATIONThe electrical motor control board can control 2-way solenoid valve, pumps, motors, lights and other running freely.\u003c\/li\u003e\n \u003cli\u003eTIME RANGEThe time range of the module is 0.1 seconds to 999 minutes and is adjustable any time.\u003c\/li\u003e\n \u003cli\u003eOUTPUT POWERThe motor control board can control within 30A DC or AC load.\u003c\/li\u003e\n \u003cli\u003eGOOD PERFORMANCEThe motor timer relay module with good performance, also is easy to install and has a long service life.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-06-26T19:33:57+10:00","created_at":"2022-06-26T19:34:06+10:00","vendor":"Hilitand","type":"Controls","tags":["industrial"],"price":12900,"price_min":12900,"price_max":12900,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41609498755252,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B07QDGSFQC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"YYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module","public_title":null,"options":["Default Title"],"price":12900,"weight":107,"compare_at_price":null,"inventory_management":null,"barcode":"0747333737042","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B07QDGSFQC.jpg?v=1656311699","\/\/auspowers.com\/cdn\/shop\/products\/61emM3GySnL.jpg?v=1656236046","\/\/auspowers.com\/cdn\/shop\/products\/61CWSq6OQQL.jpg?v=1656236046","\/\/auspowers.com\/cdn\/shop\/products\/61r7EzMgKxL.jpg?v=1656236046","\/\/auspowers.com\/cdn\/shop\/products\/71ey1RGj1tL.jpg?v=1656236046","\/\/auspowers.com\/cdn\/shop\/products\/61Ca_5CD43L.jpg?v=1656236046","\/\/auspowers.com\/cdn\/shop\/products\/612XaRmr06L.jpg?v=1656236046","\/\/auspowers.com\/cdn\/shop\/products\/61QVX93kCwL.jpg?v=1656236046","\/\/auspowers.com\/cdn\/shop\/products\/71sgneCFbIL.jpg?v=1656236046"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B07QDGSFQC.jpg?v=1656311699","options":["Title"],"media":[{"alt":"[Australia - AusPower] - YYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module ","id":26304851280052,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B07QDGSFQC.jpg?v=1656311699"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B07QDGSFQC.jpg?v=1656311699","width":1001},{"alt":"[Australia - AusPower] - YYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module ","id":26294737043636,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61emM3GySnL.jpg?v=1656236046"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61emM3GySnL.jpg?v=1656236046","width":1001},{"alt":"[Australia - AusPower] - YYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module ","id":26294737076404,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61CWSq6OQQL.jpg?v=1656236046"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61CWSq6OQQL.jpg?v=1656236046","width":1001},{"alt":"[Australia - AusPower] - YYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module ","id":26294737109172,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61r7EzMgKxL.jpg?v=1656236046"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61r7EzMgKxL.jpg?v=1656236046","width":1001},{"alt":"[Australia - AusPower] - YYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module ","id":26294737141940,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71ey1RGj1tL.jpg?v=1656236046"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71ey1RGj1tL.jpg?v=1656236046","width":1001},{"alt":"[Australia - AusPower] - YYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module ","id":26294737174708,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61Ca_5CD43L.jpg?v=1656236046"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61Ca_5CD43L.jpg?v=1656236046","width":1001},{"alt":"[Australia - AusPower] - YYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module ","id":26294737207476,"position":7,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/612XaRmr06L.jpg?v=1656236046"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/612XaRmr06L.jpg?v=1656236046","width":1001},{"alt":"[Australia - AusPower] - YYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module ","id":26294737240244,"position":8,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61QVX93kCwL.jpg?v=1656236046"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61QVX93kCwL.jpg?v=1656236046","width":1001},{"alt":"[Australia - AusPower] - YYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module ","id":26294737273012,"position":9,"preview_image":{"aspect_ratio":1.0,"height":1001,"width":1001,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71sgneCFbIL.jpg?v=1656236046"},"aspect_ratio":1.0,"height":1001,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71sgneCFbIL.jpg?v=1656236046","width":1001}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eYYB-5 12v 24v Forward\/Reverse Motor Control Board Two Relay Timing Cycle Module\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eSpecification: The two-way pump controller has 6 common\nfunctions, and the functions can be set arbitrarily to meet more application\nneeds; it can control 2 way solenoid valves, water pumps, motors, light\nstrips, etc. Read more Key Settings Description: Power display \"----\" that\naccess to standby; Press the first time K1, the screen shows: P-1: K2 and K3\nadjustment mode Press the second time K1, the screen shows: A001: K2 and K3\nadjust the first time A, K4 adjust the decimal point (time unit) Press the\nthird time K1, the screen shows: B001: K2 and K3 adjust the second time B, K4\nadjust the decimal point (time unit) Press the fourth time K1, the screen\nshows: C001: K2 and K3 adjust the third time C, K4 adjust the decimal point\n(time unit) Press the fifth K1, display \"----\" that entered the standby state;\nFor example; need to set the mode: P - 2; time: A010 B005 C006: Indicating the\nsecond mode of operation; after the signal 1; relay 1 after 10 seconds to\nstart off; relay 2 to give the signal after delay 5 seconds after the start 1\nsecond automatically shut down Read more Model:YYB-5 Input voltage: DC\/ AC\n7V~27V Time range: 0.1 seconds to 999 minutes Weight: Approx.103g\/3.6oz Read\nmore Wiring port Description: 1. AC\/DC : Input 7V~27V 2. IN1: Signal input 1\n(negative trigger) 3. IN2: Signal input terminal 2 (negative trigger) 4. IN3:\nSignal input 3 (negative trigger) 5. NO: relay normally open interface, relay\npull before the suspension, after the connection with the COM shorted 6. COM:\nrelay common interface 7. NC: relay normally closed interface, the relay\nbefore the connection with the COM shorted, pull after the suspension Read\nmore Function list: P - 1: to signal 1, relay 1 pulls to A time automatically\nstops; to signal 2, relay 2 pulls to B time automatically stops; signal 3 is\nemergency stop reset signal P - 2: signal 1, relay 1 is pulled to A time\nautomatically stop; relay 2 from the signal to start delay B time after the\nsuction to C time automatically stop (this function time unit needs to be\nconsistent) P - 3: After power on, relay 1 pulls up to A time release, waiting\nfor C time, relay 2 pulls to B time release, waits for C time; relay 1,2 turns\nendless operation endless cycle (If the control motor is reversible can be\nunderstood as: the motor is running a period of time; stop for some time;\nautomatically reverse for some time; stop for some time; then automatically\nforward; P - 4: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stops\nand starts counting to A time relay 2 pull; to signal 3 (limit), relay 2 stops\nand starts timing To B time relay 1 pull; infinite loop (If the control motor\nis reversible can be understood as: press the start button 1; the motor is\nmoving to the limit 2 to stop for a period of time; automatically reverse to\nthe limit 3 to stop a period of time; then automatically forward; P - 5: to\nsignal 1, relay 1 pull; to signal 2 (limit), relay 1 stop and start timing to\nA time relay 2 pull; give signal 3 (limit), relay 2 stop; Signal 1; once again\n(If the control motor is reversible can be understood as: press the start\nbutton 1; the motor is moving to the limit 2 to stop for a period of time;\nautomatically reverse to the limit 3 stop; give the signal 1; P-6: to signal\n1, relay 1 pull; to signal 2 (limit), relay 1 stop; give signal 1, relay 2\npull; to signal 3 (limit), relay 2 stop; (If the control motor is reversible\ncan be understood as: press the start button 1; go to the limit 2 stop; press\nthe start button 1 again; reverse to the limit 3 stop; If the remote control\nfunction: remote control A key and B key to start the above function; C key\npress the relay 1 work (forward); then press the relay 1 to stop (stop); D key\npress the relay 2 work (reverse); Press once relay 2 to stop (stop); Read more\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003e6 KINDS OF FUNCTIONSThe module has 6 kinds of commonly used functions to meet the needs of more applications.\u003c\/li\u003e\n \u003cli\u003eWIDE APPLICATIONThe electrical motor control board can control 2-way solenoid valve, pumps, motors, lights and other running freely.\u003c\/li\u003e\n \u003cli\u003eTIME RANGEThe time range of the module is 0.1 seconds to 999 minutes and is adjustable any time.\u003c\/li\u003e\n \u003cli\u003eOUTPUT POWERThe motor control board can control within 30A DC or AC load.\u003c\/li\u003e\n \u003cli\u003eGOOD PERFORMANCEThe motor timer relay module with good performance, also is easy to install and has a long service life.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

YYB-5 12v 24v Forward/Reverse Motor Control Board Two Relay Timing Cycle Module

In Stock. Leaves warehouse within 2 - 3 business days

$129.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

YYB-5 12v 24v Forward/Reverse Motor Control Board Two Relay Timing Cycle Module

Specification: The two-way pump controller has 6 common functions, and the functions can be set arbitrarily to meet more application needs; it can control 2 way solenoid valves, water pumps, motors, light strips, etc. Read more Key Settings Description: Power display "----" that access to standby; Press the first time K1, the screen shows: P-1: K2 and K3 adjustment mode Press the second time K1, the screen shows: A001: K2 and K3 adjust the first time A, K4 adjust the decimal point (time unit) Press the third time K1, the screen shows: B001: K2 and K3 adjust the second time B, K4 adjust the decimal point (time unit) Press the fourth time K1, the screen shows: C001: K2 and K3 adjust the third time C, K4 adjust the decimal point (time unit) Press the fifth K1, display "----" that entered the standby state; For example; need to set the mode: P - 2; time: A010 B005 C006: Indicating the second mode of operation; after the signal 1; relay 1 after 10 seconds to start off; relay 2 to give the signal after delay 5 seconds after the start 1 second automatically shut down Read more Model:YYB-5 Input voltage: DC/ AC 7V~27V Time range: 0.1 seconds to 999 minutes Weight: Approx.103g/3.6oz Read more Wiring port Description: 1. AC/DC : Input 7V~27V 2. IN1: Signal input 1 (negative trigger) 3. IN2: Signal input terminal 2 (negative trigger) 4. IN3: Signal input 3 (negative trigger) 5. NO: relay normally open interface, relay pull before the suspension, after the connection with the COM shorted 6. COM: relay common interface 7. NC: relay normally closed interface, the relay before the connection with the COM shorted, pull after the suspension Read more Function list: P - 1: to signal 1, relay 1 pulls to A time automatically stops; to signal 2, relay 2 pulls to B time automatically stops; signal 3 is emergency stop reset signal P - 2: signal 1, relay 1 is pulled to A time automatically stop; relay 2 from the signal to start delay B time after the suction to C time automatically stop (this function time unit needs to be consistent) P - 3: After power on, relay 1 pulls up to A time release, waiting for C time, relay 2 pulls to B time release, waits for C time; relay 1,2 turns endless operation endless cycle (If the control motor is reversible can be understood as: the motor is running a period of time; stop for some time; automatically reverse for some time; stop for some time; then automatically forward; P - 4: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stops and starts counting to A time relay 2 pull; to signal 3 (limit), relay 2 stops and starts timing To B time relay 1 pull; infinite loop (If the control motor is reversible can be understood as: press the start button 1; the motor is moving to the limit 2 to stop for a period of time; automatically reverse to the limit 3 to stop a period of time; then automatically forward; P - 5: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stop and start timing to A time relay 2 pull; give signal 3 (limit), relay 2 stop; Signal 1; once again (If the control motor is reversible can be understood as: press the start button 1; the motor is moving to the limit 2 to stop for a period of time; automatically reverse to the limit 3 stop; give the signal 1; P-6: to signal 1, relay 1 pull; to signal 2 (limit), relay 1 stop; give signal 1, relay 2 pull; to signal 3 (limit), relay 2 stop; (If the control motor is reversible can be understood as: press the start button 1; go to the limit 2 stop; press the start button 1 again; reverse to the limit 3 stop; If the remote control function: remote control A key and B key to start the above function; C key press the relay 1 work (forward); then press the relay 1 to stop (stop); D key press the relay 2 work (reverse); Press once relay 2 to stop (stop); Read more

Product Features

  • 6 KINDS OF FUNCTIONSThe module has 6 kinds of commonly used functions to meet the needs of more applications.
  • WIDE APPLICATIONThe electrical motor control board can control 2-way solenoid valve, pumps, motors, lights and other running freely.
  • TIME RANGEThe time range of the module is 0.1 seconds to 999 minutes and is adjustable any time.
  • OUTPUT POWERThe motor control board can control within 30A DC or AC load.
  • GOOD PERFORMANCEThe motor timer relay module with good performance, also is easy to install and has a long service life.