{"id":7087009497268,"title":"Welded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil 13mm 0.22um","handle":"welded-syringe-filters-pack-of-100-nylon-membrane-diameter-13mm-pore-size-0-22μm-non-sterile-filtration-for-laboratory-filtration-by-labfil-13mm-0-22um","description":"\u003ch3\u003eWelded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eNylon (PA) - Hydrophilic Benefits: Molding in place, over\nmolding and support structure molding of fragile mediaUltrasonic welding of\nbarrel structure for increased leak \/ burst resistanceDigital variable print\ncapabilities along arc on barrel face for identification purposesPure virgin\nPP, verified by HPLC against U\/L extractables Characteristics: Hydrophilic\nmaterial; it is recommended for filtration of aqueous or organic\/aqueous\nmedium polar liquidsCommonly used for general laboratory filtration and\nfiltration of HPLC and GC samples prior to injectionFiltration of aqueous and\norganic-aqueous polar medium liquidsDissolution sample analysisSuitable for\nuse with high pH samples APPLICATION: Especially ideal for HPLC operationWater\nor organic solvent solution Features: Hydrophilic High protein binding\nResistant to chemicals and HPLC solvents Broad compatibility with aqueous and\norganic solvents Read more 25mm welded nylon syringe filter Material of\nhousing : PPEffective filtration area(cm²): 4.15cm²Pore size : 0.22um \/\n0.45umProcess volume(ml) : <100mlMaximum Operating Temperature : 100℃Maximum\nOperating Pressure(psi) : 87psi 13mm welded nylon syringe filter Material of\nhousing : PPEffective filtration area(cm²): 1.13cm²Pore size : 0.22um \/ 0.45um\nProcess volume(ml) : <10ml Maximum Operating Temperature : 100℃Maximum\nOperating Pressure(psi) : 87psi Read more How to Choose Right Syringe Filter —\nFilter Membrane Materials NYLON (NY) Nylon membrane has high strong mechanical\nstrength, chemical stability, can be tolerated by most organic solvents,\nextremely low in extractables, good thermal stability (up to 50°C), natural\nhydrophilic and the majority of water solution filter characteristics. It more\noften applied to the common organic solvent HPLC mobile phase filtering.\nMembrane: HPLC Certified Nylon.Use with: Bases, Most HPLC solvents, Alcohols,\nAromatic Hydrocarbons, THF.Don’t use with: Acids, Aggressive Halogenated\nhydrocarbons, protein samples (Nylon is a high binder) How to Choose Right\nSyringe Filter — Filter Membrane Materials Polytetrafluoroethylene (PTFE) PTFE\nmembranes are chemically resistant to nearly all solvents, acids and bases.\nThe membrane has low extractable and good thermal stability. Membrane: HPLC\ncertified PTFE, with polypropylene supportUse with: Aggressive solvents,\nstrong acids, alcohols, bases, aromaticsApplications: Filtration of aggressive\norganic or highly basic solutions, transducer protectors. How to Choose Right\nSyringe Filter — Filter Membrane Materials Polyethersulphone (PES)\nPolyethersulphone is a hydrophilic membrane that has very low protein binding\nand high flow characteristics. It is also certified for ion chromatography.\nPolyethersulphone is more heat resistant than most membranes, and can be used\nto 100°C. Membrane: ICP Certified PES (Polyethersulfone)Use with: Strong\nbases, alcohols, proteins, peptidesDon’t use with: acids, ketones, esters,\nhalogenated or aromatic hydrocarbons. Sterile Syringe Filters Nylon Sterile\nSyringe Filters Nylon Diameter 25mm 25mm Pore size 0.22um 0.45um Sterile ✓ ✓\nMembrance NYLON NYLON Package 20pcs\/pk 20pcs\/pk Printing ✓ ✓ 2ml Syringe 5ml\nSyringe 10ml Syringe Material Plastic Plastic Plastic Volume 2ml 5ml 10ml\nPackage 12pcs\/pk 12pcs\/pk 12pcs\/pk\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eHigher Throughput : This Nylon + PP pre-filter provides two times greater throughput than standard filter without pre-filtration.\u003c\/li\u003e\n \u003cli\u003eHydrophilic Membrance : One of the most commonly used membrances, broad compatibility with aqucous ans organic solvents,with stable hydrophilicity,not suitable for highly acidic samples.\u003c\/li\u003e\n \u003cli\u003eApplication : Used for most organic solvents mixtures and mid-polar liquids;Chemical filtration and Beverage filtration\u003c\/li\u003e\n \u003cli\u003eProcess Volume(ml) : 0-10ml sample volume.\u003c\/li\u003e\n \u003cli\u003eNote: Nylon binds protein,do not use when high protein recovery is desired.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-03-19T06:49:25+11:00","created_at":"2022-03-19T06:49:25+11:00","vendor":"Labfil","type":"Syringe Filters","tags":["auspowers_batchone"],"price":18000,"price_min":18000,"price_max":18000,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41336257216692,"title":"13mm 0.22um","option1":"13mm 0.22um","option2":null,"option3":null,"sku":"B08393LMGP","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Welded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil 13mm 0.22um - 13mm 0.22um","public_title":"13mm 0.22um","options":["13mm 0.22um"],"price":18000,"weight":91,"compare_at_price":null,"inventory_management":null,"barcode":"0663274560191","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B08393LMGP.jpg?v=1648587285","\/\/auspowers.com\/cdn\/shop\/products\/71MVs1USLNS.jpg?v=1647632965","\/\/auspowers.com\/cdn\/shop\/products\/71pjnkHtYKS.jpg?v=1647632965","\/\/auspowers.com\/cdn\/shop\/products\/717qRCCdtnS.jpg?v=1647632965","\/\/auspowers.com\/cdn\/shop\/products\/71yB0lE-nWS.jpg?v=1647632965","\/\/auspowers.com\/cdn\/shop\/products\/61SC_1oD0fS.jpg?v=1647632965","\/\/auspowers.com\/cdn\/shop\/products\/61oC16biPnS.jpg?v=1647632965"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B08393LMGP.jpg?v=1648587285","options":["Size"],"media":[{"alt":"[Australia - AusPower] - Welded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil 13mm 0.22um ","id":25352609988788,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B08393LMGP.jpg?v=1648587285"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B08393LMGP.jpg?v=1648587285","width":1700},{"alt":"[Australia - AusPower] - Welded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil 13mm 0.22um ","id":25208528732340,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71MVs1USLNS.jpg?v=1647632965"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71MVs1USLNS.jpg?v=1647632965","width":1700},{"alt":"[Australia - AusPower] - Welded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil 13mm 0.22um ","id":25208528765108,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71pjnkHtYKS.jpg?v=1647632965"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71pjnkHtYKS.jpg?v=1647632965","width":1700},{"alt":"[Australia - AusPower] - Welded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil 13mm 0.22um ","id":25208528797876,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"\/\/auspowers.com\/cdn\/shop\/products\/717qRCCdtnS.jpg?v=1647632965"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/717qRCCdtnS.jpg?v=1647632965","width":1700},{"alt":"[Australia - AusPower] - Welded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil 13mm 0.22um ","id":25208528830644,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71yB0lE-nWS.jpg?v=1647632965"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71yB0lE-nWS.jpg?v=1647632965","width":1700},{"alt":"[Australia - AusPower] - Welded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil 13mm 0.22um ","id":25208528863412,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61SC_1oD0fS.jpg?v=1647632965"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61SC_1oD0fS.jpg?v=1647632965","width":1700},{"alt":"[Australia - AusPower] - Welded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil 13mm 0.22um ","id":25208528896180,"position":7,"preview_image":{"aspect_ratio":1.0,"height":1700,"width":1700,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61oC16biPnS.jpg?v=1647632965"},"aspect_ratio":1.0,"height":1700,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61oC16biPnS.jpg?v=1647632965","width":1700}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eWelded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eNylon (PA) - Hydrophilic Benefits: Molding in place, over\nmolding and support structure molding of fragile mediaUltrasonic welding of\nbarrel structure for increased leak \/ burst resistanceDigital variable print\ncapabilities along arc on barrel face for identification purposesPure virgin\nPP, verified by HPLC against U\/L extractables Characteristics: Hydrophilic\nmaterial; it is recommended for filtration of aqueous or organic\/aqueous\nmedium polar liquidsCommonly used for general laboratory filtration and\nfiltration of HPLC and GC samples prior to injectionFiltration of aqueous and\norganic-aqueous polar medium liquidsDissolution sample analysisSuitable for\nuse with high pH samples APPLICATION: Especially ideal for HPLC operationWater\nor organic solvent solution Features: Hydrophilic High protein binding\nResistant to chemicals and HPLC solvents Broad compatibility with aqueous and\norganic solvents Read more 25mm welded nylon syringe filter Material of\nhousing : PPEffective filtration area(cm²): 4.15cm²Pore size : 0.22um \/\n0.45umProcess volume(ml) : <100mlMaximum Operating Temperature : 100℃Maximum\nOperating Pressure(psi) : 87psi 13mm welded nylon syringe filter Material of\nhousing : PPEffective filtration area(cm²): 1.13cm²Pore size : 0.22um \/ 0.45um\nProcess volume(ml) : <10ml Maximum Operating Temperature : 100℃Maximum\nOperating Pressure(psi) : 87psi Read more How to Choose Right Syringe Filter —\nFilter Membrane Materials NYLON (NY) Nylon membrane has high strong mechanical\nstrength, chemical stability, can be tolerated by most organic solvents,\nextremely low in extractables, good thermal stability (up to 50°C), natural\nhydrophilic and the majority of water solution filter characteristics. It more\noften applied to the common organic solvent HPLC mobile phase filtering.\nMembrane: HPLC Certified Nylon.Use with: Bases, Most HPLC solvents, Alcohols,\nAromatic Hydrocarbons, THF.Don’t use with: Acids, Aggressive Halogenated\nhydrocarbons, protein samples (Nylon is a high binder) How to Choose Right\nSyringe Filter — Filter Membrane Materials Polytetrafluoroethylene (PTFE) PTFE\nmembranes are chemically resistant to nearly all solvents, acids and bases.\nThe membrane has low extractable and good thermal stability. Membrane: HPLC\ncertified PTFE, with polypropylene supportUse with: Aggressive solvents,\nstrong acids, alcohols, bases, aromaticsApplications: Filtration of aggressive\norganic or highly basic solutions, transducer protectors. How to Choose Right\nSyringe Filter — Filter Membrane Materials Polyethersulphone (PES)\nPolyethersulphone is a hydrophilic membrane that has very low protein binding\nand high flow characteristics. It is also certified for ion chromatography.\nPolyethersulphone is more heat resistant than most membranes, and can be used\nto 100°C. Membrane: ICP Certified PES (Polyethersulfone)Use with: Strong\nbases, alcohols, proteins, peptidesDon’t use with: acids, ketones, esters,\nhalogenated or aromatic hydrocarbons. Sterile Syringe Filters Nylon Sterile\nSyringe Filters Nylon Diameter 25mm 25mm Pore size 0.22um 0.45um Sterile ✓ ✓\nMembrance NYLON NYLON Package 20pcs\/pk 20pcs\/pk Printing ✓ ✓ 2ml Syringe 5ml\nSyringe 10ml Syringe Material Plastic Plastic Plastic Volume 2ml 5ml 10ml\nPackage 12pcs\/pk 12pcs\/pk 12pcs\/pk\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eHigher Throughput : This Nylon + PP pre-filter provides two times greater throughput than standard filter without pre-filtration.\u003c\/li\u003e\n \u003cli\u003eHydrophilic Membrance : One of the most commonly used membrances, broad compatibility with aqucous ans organic solvents,with stable hydrophilicity,not suitable for highly acidic samples.\u003c\/li\u003e\n \u003cli\u003eApplication : Used for most organic solvents mixtures and mid-polar liquids;Chemical filtration and Beverage filtration\u003c\/li\u003e\n \u003cli\u003eProcess Volume(ml) : 0-10ml sample volume.\u003c\/li\u003e\n \u003cli\u003eNote: Nylon binds protein,do not use when high protein recovery is desired.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

Welded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil 13mm 0.22um

In Stock. Leaves warehouse within 2 - 3 business days

$180.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Welded Syringe Filters,Pack of 100, [Nylon Membrane] Diameter 13mm Pore Size 0.22μm, Non Sterile Filtration for Laboratory Filtration by Labfil

Nylon (PA) - Hydrophilic Benefits: Molding in place, over molding and support structure molding of fragile mediaUltrasonic welding of barrel structure for increased leak / burst resistanceDigital variable print capabilities along arc on barrel face for identification purposesPure virgin PP, verified by HPLC against U/L extractables Characteristics: Hydrophilic material; it is recommended for filtration of aqueous or organic/aqueous medium polar liquidsCommonly used for general laboratory filtration and filtration of HPLC and GC samples prior to injectionFiltration of aqueous and organic-aqueous polar medium liquidsDissolution sample analysisSuitable for use with high pH samples APPLICATION: Especially ideal for HPLC operationWater or organic solvent solution Features: Hydrophilic High protein binding Resistant to chemicals and HPLC solvents Broad compatibility with aqueous and organic solvents Read more 25mm welded nylon syringe filter Material of housing : PPEffective filtration area(cm²): 4.15cm²Pore size : 0.22um / 0.45umProcess volume(ml) : <100mlMaximum Operating Temperature : 100℃Maximum Operating Pressure(psi) : 87psi 13mm welded nylon syringe filter Material of housing : PPEffective filtration area(cm²): 1.13cm²Pore size : 0.22um / 0.45um Process volume(ml) : <10ml Maximum Operating Temperature : 100℃Maximum Operating Pressure(psi) : 87psi Read more How to Choose Right Syringe Filter — Filter Membrane Materials NYLON (NY) Nylon membrane has high strong mechanical strength, chemical stability, can be tolerated by most organic solvents, extremely low in extractables, good thermal stability (up to 50°C), natural hydrophilic and the majority of water solution filter characteristics. It more often applied to the common organic solvent HPLC mobile phase filtering. Membrane: HPLC Certified Nylon.Use with: Bases, Most HPLC solvents, Alcohols, Aromatic Hydrocarbons, THF.Don’t use with: Acids, Aggressive Halogenated hydrocarbons, protein samples (Nylon is a high binder) How to Choose Right Syringe Filter — Filter Membrane Materials Polytetrafluoroethylene (PTFE) PTFE membranes are chemically resistant to nearly all solvents, acids and bases. The membrane has low extractable and good thermal stability. Membrane: HPLC certified PTFE, with polypropylene supportUse with: Aggressive solvents, strong acids, alcohols, bases, aromaticsApplications: Filtration of aggressive organic or highly basic solutions, transducer protectors. How to Choose Right Syringe Filter — Filter Membrane Materials Polyethersulphone (PES) Polyethersulphone is a hydrophilic membrane that has very low protein binding and high flow characteristics. It is also certified for ion chromatography. Polyethersulphone is more heat resistant than most membranes, and can be used to 100°C. Membrane: ICP Certified PES (Polyethersulfone)Use with: Strong bases, alcohols, proteins, peptidesDon’t use with: acids, ketones, esters, halogenated or aromatic hydrocarbons. Sterile Syringe Filters Nylon Sterile Syringe Filters Nylon Diameter 25mm 25mm Pore size 0.22um 0.45um Sterile ✓ ✓ Membrance NYLON NYLON Package 20pcs/pk 20pcs/pk Printing ✓ ✓ 2ml Syringe 5ml Syringe 10ml Syringe Material Plastic Plastic Plastic Volume 2ml 5ml 10ml Package 12pcs/pk 12pcs/pk 12pcs/pk

Product Features

  • Higher Throughput : This Nylon + PP pre-filter provides two times greater throughput than standard filter without pre-filtration.
  • Hydrophilic Membrance : One of the most commonly used membrances, broad compatibility with aqucous ans organic solvents,with stable hydrophilicity,not suitable for highly acidic samples.
  • Application : Used for most organic solvents mixtures and mid-polar liquids;Chemical filtration and Beverage filtration
  • Process Volume(ml) : 0-10ml sample volume.
  • Note: Nylon binds protein,do not use when high protein recovery is desired.

Related Products