{"id":7086902771892,"title":"PowerWell 45+5 MFD 45\/5 uf 370 or 440 Volt Dual Run Round Capacitor PW-45\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years","handle":"powerwell-45-5-mfd-45-5-uf-370-or-440-volt-dual-run-round-capacitor-pw-45-5-r-for-condenser-straight-cool-or-heat-pump-air-conditioner-guaranteed-to-last-5-years","description":"\u003ch3\u003ePowerWell 45+5 MFD 45\/5 uf 370 or 440 Volt Dual Run Round Capacitor PW-45\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eA capacitor is an electric component that temporarily stores an electrical\ncharge. A dual \"run capacitor\" supports two electric motors, such as in large\nair conditioner or heat pump units, with both a fan motor and a compressor\nmotor. It saves space by combining two physical capacitors into one case. The\ndual capacitor has three terminals labeled \"C\", \"FAN\", and \"HERM\", which stand\nfor the Common, Fan, and HERMetically sealed compressor. Dual capacitors\ncome in a variety of sizes, depending on the capacitance (µF or MFD), such as\n40 plus 5 µF, and also the voltage. A 440 volt capacitor can be used in place\nof a 370 volt, as it is build better, but the 370 can’t be used in place of a\n440 volt. It will work for a while and will fail prematurely, as exceeding the\ncapacitor's rated voltage will cause the dielectric to break down and the\ncapacitor to short out. Same as an electric wire- 600V rated wire is better\nthan 300V one .The capacitance(µF or MFD) must be the same or stay within 10%+\nor 5%- of its original value . Example: 50 µF cap can be substituted by 47.5\nto 55 µF with the same or better voltage ratings capacitor . Round cylinder-\nshaped dual run capacitors are commonly used for air conditioning, to help in\nthe starting of the compressor and the condenser fan motor.Round capacitor can\nbe used to substitute oval shape one with the same MFD AND Volt specs You will\nask “Why I need a Cap that is rated 440V in my A\/C?” Answer: You need to\nrealize that a motor is an inductive device. When the supply voltage is\napplied to the motor run winding, the voltage across the start winding will be\nincreased to a higher voltage value. A motor acts like a transformer with the\nrun winding acting as the primary and the start winding acting as the\nsecondary. This is why the capacitor has a much higher voltage rating than the\n230 being the supply voltage. If a Capacitor is not EIA-456-A approved means\nit is not approved for US market.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003e45+5 uf or 45+5 MFD 440 Volt AC Capacitor. Replaces BOTH 370 VAC \u0026amp; 440 VAC capacitors\u003c\/li\u003e\n \u003cli\u003eCan size measures 2-3\/8\" diameter x 4\" tall. Operating temperature range -40 C. to +70 C\/ -40F to 158\u003c\/li\u003e\n \u003cli\u003eBuilt to the TOUGHEST USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001\u003c\/li\u003e\n \u003cli\u003eGUARANTEED TO LAST 5 YEARS. We are extremely passionate about our products and are fanatical about quality control in our workshops. ORDER NOW with peace of mind. No Catches\u003c\/li\u003e\n \u003cli\u003eReplacement for 97F9895 , Z97F995 , 97F9895BZ3 , 27L880 , TRCD455 , TRCFD455 , PRCFD455 , 27L889 , 97F9851 , 97F9851S , 12788 , RC0114 , Z97F9895 , 97F9895 , TT-CAP-45\/5\/440R , HC98KA046 , TP-CAP-45\/5\/440R , CAP050450440RT , HC98JA046 , HCKS450D050R440Z , 62\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-03-19T05:57:14+11:00","created_at":"2022-03-19T05:57:14+11:00","vendor":"PowerWell","type":"Capacitors","tags":["auspowers_batchone"],"price":13800,"price_min":13800,"price_max":13800,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41336087609524,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B01NAZJYWA","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"PowerWell 45+5 MFD 45\/5 uf 370 or 440 Volt Dual Run Round Capacitor PW-45\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years","public_title":null,"options":["Default Title"],"price":13800,"weight":322,"compare_at_price":null,"inventory_management":null,"barcode":"714833366249","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B01NAZJYWA.jpg?v=1648584336","\/\/auspowers.com\/cdn\/shop\/products\/41Z7z32oBEL.jpg?v=1647629835","\/\/auspowers.com\/cdn\/shop\/products\/516elA1GApL_929e041e-0fba-4392-8036-0d80d99df587.jpg?v=1647629835"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B01NAZJYWA.jpg?v=1648584336","options":["Title"],"media":[{"alt":"[Australia - AusPower] - PowerWell 45+5 MFD 45\/5 uf 370 or 440 Volt Dual Run Round Capacitor PW-45\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years ","id":25352226734260,"position":1,"preview_image":{"aspect_ratio":0.719,"height":1378,"width":991,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B01NAZJYWA.jpg?v=1648584336"},"aspect_ratio":0.719,"height":1378,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B01NAZJYWA.jpg?v=1648584336","width":991},{"alt":"[Australia - AusPower] - PowerWell 45+5 MFD 45\/5 uf 370 or 440 Volt Dual Run Round Capacitor PW-45\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years ","id":25207883006132,"position":2,"preview_image":{"aspect_ratio":1.04,"height":481,"width":500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/41Z7z32oBEL.jpg?v=1647629835"},"aspect_ratio":1.04,"height":481,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/41Z7z32oBEL.jpg?v=1647629835","width":500},{"alt":"[Australia - AusPower] - PowerWell 45+5 MFD 45\/5 uf 370 or 440 Volt Dual Run Round Capacitor PW-45\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years ","id":25207883038900,"position":3,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/516elA1GApL_929e041e-0fba-4392-8036-0d80d99df587.jpg?v=1647629835"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/516elA1GApL_929e041e-0fba-4392-8036-0d80d99df587.jpg?v=1647629835","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003ePowerWell 45+5 MFD 45\/5 uf 370 or 440 Volt Dual Run Round Capacitor PW-45\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eA capacitor is an electric component that temporarily stores an electrical\ncharge. A dual \"run capacitor\" supports two electric motors, such as in large\nair conditioner or heat pump units, with both a fan motor and a compressor\nmotor. It saves space by combining two physical capacitors into one case. The\ndual capacitor has three terminals labeled \"C\", \"FAN\", and \"HERM\", which stand\nfor the Common, Fan, and HERMetically sealed compressor. Dual capacitors\ncome in a variety of sizes, depending on the capacitance (µF or MFD), such as\n40 plus 5 µF, and also the voltage. A 440 volt capacitor can be used in place\nof a 370 volt, as it is build better, but the 370 can’t be used in place of a\n440 volt. It will work for a while and will fail prematurely, as exceeding the\ncapacitor's rated voltage will cause the dielectric to break down and the\ncapacitor to short out. Same as an electric wire- 600V rated wire is better\nthan 300V one .The capacitance(µF or MFD) must be the same or stay within 10%+\nor 5%- of its original value . Example: 50 µF cap can be substituted by 47.5\nto 55 µF with the same or better voltage ratings capacitor . Round cylinder-\nshaped dual run capacitors are commonly used for air conditioning, to help in\nthe starting of the compressor and the condenser fan motor.Round capacitor can\nbe used to substitute oval shape one with the same MFD AND Volt specs You will\nask “Why I need a Cap that is rated 440V in my A\/C?” Answer: You need to\nrealize that a motor is an inductive device. When the supply voltage is\napplied to the motor run winding, the voltage across the start winding will be\nincreased to a higher voltage value. A motor acts like a transformer with the\nrun winding acting as the primary and the start winding acting as the\nsecondary. This is why the capacitor has a much higher voltage rating than the\n230 being the supply voltage. If a Capacitor is not EIA-456-A approved means\nit is not approved for US market.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003e45+5 uf or 45+5 MFD 440 Volt AC Capacitor. Replaces BOTH 370 VAC \u0026amp; 440 VAC capacitors\u003c\/li\u003e\n \u003cli\u003eCan size measures 2-3\/8\" diameter x 4\" tall. Operating temperature range -40 C. to +70 C\/ -40F to 158\u003c\/li\u003e\n \u003cli\u003eBuilt to the TOUGHEST USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001\u003c\/li\u003e\n \u003cli\u003eGUARANTEED TO LAST 5 YEARS. We are extremely passionate about our products and are fanatical about quality control in our workshops. ORDER NOW with peace of mind. No Catches\u003c\/li\u003e\n \u003cli\u003eReplacement for 97F9895 , Z97F995 , 97F9895BZ3 , 27L880 , TRCD455 , TRCFD455 , PRCFD455 , 27L889 , 97F9851 , 97F9851S , 12788 , RC0114 , Z97F9895 , 97F9895 , TT-CAP-45\/5\/440R , HC98KA046 , TP-CAP-45\/5\/440R , CAP050450440RT , HC98JA046 , HCKS450D050R440Z , 62\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

PowerWell 45+5 MFD 45/5 uf 370 or 440 Volt Dual Run Round Capacitor PW-45/5/R for Condenser Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years

In Stock. Leaves warehouse within 2 - 3 business days

$138.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

PowerWell 45+5 MFD 45/5 uf 370 or 440 Volt Dual Run Round Capacitor PW-45/5/R for Condenser Straight Cool or Heat Pump Air Conditioner - Guaranteed to Last 5 Years

A capacitor is an electric component that temporarily stores an electrical charge. A dual "run capacitor" supports two electric motors, such as in large air conditioner or heat pump units, with both a fan motor and a compressor motor. It saves space by combining two physical capacitors into one case. The dual capacitor has three terminals labeled "C", "FAN", and "HERM", which stand for the Common, Fan, and HERMetically sealed compressor. Dual capacitors come in a variety of sizes, depending on the capacitance (µF or MFD), such as 40 plus 5 µF, and also the voltage. A 440 volt capacitor can be used in place of a 370 volt, as it is build better, but the 370 can’t be used in place of a 440 volt. It will work for a while and will fail prematurely, as exceeding the capacitor's rated voltage will cause the dielectric to break down and the capacitor to short out. Same as an electric wire- 600V rated wire is better than 300V one .The capacitance(µF or MFD) must be the same or stay within 10%+ or 5%- of its original value . Example: 50 µF cap can be substituted by 47.5 to 55 µF with the same or better voltage ratings capacitor . Round cylinder- shaped dual run capacitors are commonly used for air conditioning, to help in the starting of the compressor and the condenser fan motor.Round capacitor can be used to substitute oval shape one with the same MFD AND Volt specs You will ask “Why I need a Cap that is rated 440V in my A/C?” Answer: You need to realize that a motor is an inductive device. When the supply voltage is applied to the motor run winding, the voltage across the start winding will be increased to a higher voltage value. A motor acts like a transformer with the run winding acting as the primary and the start winding acting as the secondary. This is why the capacitor has a much higher voltage rating than the 230 being the supply voltage. If a Capacitor is not EIA-456-A approved means it is not approved for US market.

Product Features

  • 45+5 uf or 45+5 MFD 440 Volt AC Capacitor. Replaces BOTH 370 VAC & 440 VAC capacitors
  • Can size measures 2-3/8" diameter x 4" tall. Operating temperature range -40 C. to +70 C/ -40F to 158
  • Built to the TOUGHEST USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001
  • GUARANTEED TO LAST 5 YEARS. We are extremely passionate about our products and are fanatical about quality control in our workshops. ORDER NOW with peace of mind. No Catches
  • Replacement for 97F9895 , Z97F995 , 97F9895BZ3 , 27L880 , TRCD455 , TRCFD455 , PRCFD455 , 27L889 , 97F9851 , 97F9851S , 12788 , RC0114 , Z97F9895 , 97F9895 , TT-CAP-45/5/440R , HC98KA046 , TP-CAP-45/5/440R , CAP050450440RT , HC98JA046 , HCKS450D050R440Z , 62

Related Products