{"id":7086909817012,"title":"PowerWell 35 + 5 MFD uf 370 VAC or 440 Volt Dual Run Round Capacitor PW-35\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner 35\/5 Micro Farad – Guaranteed to Last 5 Years","handle":"powerwell-35-5-mfd-uf-370-vac-or-440-volt-dual-run-round-capacitor-pw-35-5-r-for-condenser-straight-cool-or-heat-pump-air-conditioner-35-5-micro-farad-guaranteed-to-last-5-years","description":"\u003ch3\u003ePowerWell 35 + 5 MFD uf 370 VAC or 440 Volt Dual Run Round Capacitor PW-35\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner 35\/5 Micro Farad – Guaranteed to Last 5 Years\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eA capacitor is an electric component that temporarily stores an electrical\ncharge. A dual \"run capacitor\" supports two electric motors, such as a fan\nmotor and a compressor. Round dual run capacitors are used to start and run\nthe unit more efficient. It saves space by combining two physical capacitors\ninto one case. The dual capacitor has three terminals labeled \"C\", \"FAN\", and\n\"HERM\", which stand for the Common, Fan, and HERMetically sealed\ncompressor.Dual capacitors come in a variety of sizes, depending on the\ncapacitance (µF = MFD = micro farad), such as 60 plus 5 µF, and also the\nvoltage. A 440 volt capacitor can be used in place of a 370 volt, as it is\nbuild better, but the 370 can’t be used in place of a 440 volt. It will work\nfor a while and will fail prematurely, as exceeding the capacitor's rated\nvoltage will cause the dielectric to break down and the capacitor to short\nout. Same as an electric wire- 600V rated wire is better than 300V one .The\ncapacitance(µF or MFD or micro farad) must be the same or stay within 10%+ or\n5%- of its original value . Example: 35 µF cap can be substituted by 33 - 38\nMFD with the same or better voltage ratings capacitor.If your fan is working\nbut compressor not, or the capacitor is bulged on top most likely your\ncapacitor is defective. Round capacitor can be used to substitute oval shape\none with the same MFD AND Volt specs.You will ask “Why I need a Cap that is\nrated 440V in my A\/C?”Answer: You need to realize that a motor is an inductive\ndevice. When the supply voltage is applied to the motor run winding, the\nvoltage across the start winding will be increased to a higher voltage value.\nA motor acts like a transformer with the run winding acting as the primary and\nthe start winding acting as the secondary. This is why the capacitor has a\nmuch higher voltage rating than the 230 being the supply voltage.If a\nCapacitor is not EIA-456-A approved means it is NOT approved for USA market.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003e35\/5 uf or MFD micro farad 440 Volt Dual Run Round AC Capacitor . Replaces BOTH 370 \u0026amp; 440 VAC capacitors\u003c\/li\u003e\n \u003cli\u003eCan size measures 2\" diameter x 4.75\" tall.\u003c\/li\u003e\n \u003cli\u003eBuilt to the toughest USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001\u003c\/li\u003e\n \u003cli\u003eOperating temperature range -40 C. to +70 C\/ -40F to 158F\u003c\/li\u003e\n \u003cli\u003eReplacement for 97F9834 , Z97F9834 , HC98JA036 , P291-3553R , HC98CA036 , HV98CA035 , 97F9834, R100335-05, 89M73, HC98JA036D , TT-CAP-35\/5\/440R, RC0102 , TRCFD355 , 12283 , Z97F9848 , Z97F9899 , 97F9899 , cap050350440rs , 12266 , TP-CAP-35\/5\/440R\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-03-19T06:01:24+11:00","created_at":"2022-03-19T06:01:24+11:00","vendor":"PowerWell","type":"Capacitors","tags":["auspowers_batchone"],"price":12400,"price_min":12400,"price_max":12400,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41336101732532,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B0713V111K","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"PowerWell 35 + 5 MFD uf 370 VAC or 440 Volt Dual Run Round Capacitor PW-35\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner 35\/5 Micro Farad – Guaranteed to Last 5 Years","public_title":null,"options":["Default Title"],"price":12400,"weight":259,"compare_at_price":null,"inventory_management":null,"barcode":"817506022777","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B0713V111K.jpg?v=1648584484","\/\/auspowers.com\/cdn\/shop\/products\/41QWy8_IC_L.jpg?v=1647630084","\/\/auspowers.com\/cdn\/shop\/products\/516elA1GApL_791bc458-e714-4a06-a768-ac28555b1d1e.jpg?v=1647630084"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B0713V111K.jpg?v=1648584484","options":["Title"],"media":[{"alt":"[Australia - AusPower] - PowerWell 35 + 5 MFD uf 370 VAC or 440 Volt Dual Run Round Capacitor PW-35\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner 35\/5 Micro Farad – Guaranteed to Last 5 Years ","id":25352241479860,"position":1,"preview_image":{"aspect_ratio":0.478,"height":1456,"width":696,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B0713V111K.jpg?v=1648584484"},"aspect_ratio":0.478,"height":1456,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B0713V111K.jpg?v=1648584484","width":696},{"alt":"[Australia - AusPower] - PowerWell 35 + 5 MFD uf 370 VAC or 440 Volt Dual Run Round Capacitor PW-35\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner 35\/5 Micro Farad – Guaranteed to Last 5 Years ","id":25207915380916,"position":2,"preview_image":{"aspect_ratio":1.04,"height":481,"width":500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/41QWy8_IC_L.jpg?v=1647630084"},"aspect_ratio":1.04,"height":481,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/41QWy8_IC_L.jpg?v=1647630084","width":500},{"alt":"[Australia - AusPower] - PowerWell 35 + 5 MFD uf 370 VAC or 440 Volt Dual Run Round Capacitor PW-35\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner 35\/5 Micro Farad – Guaranteed to Last 5 Years ","id":25207915413684,"position":3,"preview_image":{"aspect_ratio":1.0,"height":500,"width":500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/516elA1GApL_791bc458-e714-4a06-a768-ac28555b1d1e.jpg?v=1647630084"},"aspect_ratio":1.0,"height":500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/516elA1GApL_791bc458-e714-4a06-a768-ac28555b1d1e.jpg?v=1647630084","width":500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003ePowerWell 35 + 5 MFD uf 370 VAC or 440 Volt Dual Run Round Capacitor PW-35\/5\/R for Condenser Straight Cool or Heat Pump Air Conditioner 35\/5 Micro Farad – Guaranteed to Last 5 Years\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eA capacitor is an electric component that temporarily stores an electrical\ncharge. A dual \"run capacitor\" supports two electric motors, such as a fan\nmotor and a compressor. Round dual run capacitors are used to start and run\nthe unit more efficient. It saves space by combining two physical capacitors\ninto one case. The dual capacitor has three terminals labeled \"C\", \"FAN\", and\n\"HERM\", which stand for the Common, Fan, and HERMetically sealed\ncompressor.Dual capacitors come in a variety of sizes, depending on the\ncapacitance (µF = MFD = micro farad), such as 60 plus 5 µF, and also the\nvoltage. A 440 volt capacitor can be used in place of a 370 volt, as it is\nbuild better, but the 370 can’t be used in place of a 440 volt. It will work\nfor a while and will fail prematurely, as exceeding the capacitor's rated\nvoltage will cause the dielectric to break down and the capacitor to short\nout. Same as an electric wire- 600V rated wire is better than 300V one .The\ncapacitance(µF or MFD or micro farad) must be the same or stay within 10%+ or\n5%- of its original value . Example: 35 µF cap can be substituted by 33 - 38\nMFD with the same or better voltage ratings capacitor.If your fan is working\nbut compressor not, or the capacitor is bulged on top most likely your\ncapacitor is defective. Round capacitor can be used to substitute oval shape\none with the same MFD AND Volt specs.You will ask “Why I need a Cap that is\nrated 440V in my A\/C?”Answer: You need to realize that a motor is an inductive\ndevice. When the supply voltage is applied to the motor run winding, the\nvoltage across the start winding will be increased to a higher voltage value.\nA motor acts like a transformer with the run winding acting as the primary and\nthe start winding acting as the secondary. This is why the capacitor has a\nmuch higher voltage rating than the 230 being the supply voltage.If a\nCapacitor is not EIA-456-A approved means it is NOT approved for USA market.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003e35\/5 uf or MFD micro farad 440 Volt Dual Run Round AC Capacitor . Replaces BOTH 370 \u0026amp; 440 VAC capacitors\u003c\/li\u003e\n \u003cli\u003eCan size measures 2\" diameter x 4.75\" tall.\u003c\/li\u003e\n \u003cli\u003eBuilt to the toughest USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001\u003c\/li\u003e\n \u003cli\u003eOperating temperature range -40 C. to +70 C\/ -40F to 158F\u003c\/li\u003e\n \u003cli\u003eReplacement for 97F9834 , Z97F9834 , HC98JA036 , P291-3553R , HC98CA036 , HV98CA035 , 97F9834, R100335-05, 89M73, HC98JA036D , TT-CAP-35\/5\/440R, RC0102 , TRCFD355 , 12283 , Z97F9848 , Z97F9899 , 97F9899 , cap050350440rs , 12266 , TP-CAP-35\/5\/440R\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

PowerWell 35 + 5 MFD uf 370 VAC or 440 Volt Dual Run Round Capacitor PW-35/5/R for Condenser Straight Cool or Heat Pump Air Conditioner 35/5 Micro Farad – Guaranteed to Last 5 Years

In Stock. Leaves warehouse within 2 - 3 business days

$124.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

PowerWell 35 + 5 MFD uf 370 VAC or 440 Volt Dual Run Round Capacitor PW-35/5/R for Condenser Straight Cool or Heat Pump Air Conditioner 35/5 Micro Farad – Guaranteed to Last 5 Years

A capacitor is an electric component that temporarily stores an electrical charge. A dual "run capacitor" supports two electric motors, such as a fan motor and a compressor. Round dual run capacitors are used to start and run the unit more efficient. It saves space by combining two physical capacitors into one case. The dual capacitor has three terminals labeled "C", "FAN", and "HERM", which stand for the Common, Fan, and HERMetically sealed compressor.Dual capacitors come in a variety of sizes, depending on the capacitance (µF = MFD = micro farad), such as 60 plus 5 µF, and also the voltage. A 440 volt capacitor can be used in place of a 370 volt, as it is build better, but the 370 can’t be used in place of a 440 volt. It will work for a while and will fail prematurely, as exceeding the capacitor's rated voltage will cause the dielectric to break down and the capacitor to short out. Same as an electric wire- 600V rated wire is better than 300V one .The capacitance(µF or MFD or micro farad) must be the same or stay within 10%+ or 5%- of its original value . Example: 35 µF cap can be substituted by 33 - 38 MFD with the same or better voltage ratings capacitor.If your fan is working but compressor not, or the capacitor is bulged on top most likely your capacitor is defective. Round capacitor can be used to substitute oval shape one with the same MFD AND Volt specs.You will ask “Why I need a Cap that is rated 440V in my A/C?”Answer: You need to realize that a motor is an inductive device. When the supply voltage is applied to the motor run winding, the voltage across the start winding will be increased to a higher voltage value. A motor acts like a transformer with the run winding acting as the primary and the start winding acting as the secondary. This is why the capacitor has a much higher voltage rating than the 230 being the supply voltage.If a Capacitor is not EIA-456-A approved means it is NOT approved for USA market.

Product Features

  • 35/5 uf or MFD micro farad 440 Volt Dual Run Round AC Capacitor . Replaces BOTH 370 & 440 VAC capacitors
  • Can size measures 2" diameter x 4.75" tall.
  • Built to the toughest USA standards for AC motor run capacitors including EIA-456-A and IEC 60252-1:2001
  • Operating temperature range -40 C. to +70 C/ -40F to 158F
  • Replacement for 97F9834 , Z97F9834 , HC98JA036 , P291-3553R , HC98CA036 , HV98CA035 , 97F9834, R100335-05, 89M73, HC98JA036D , TT-CAP-35/5/440R, RC0102 , TRCFD355 , 12283 , Z97F9848 , Z97F9899 , 97F9899 , cap050350440rs , 12266 , TP-CAP-35/5/440R