{"id":7086488027316,"title":"Geekpure 75 GPD Reverse Osmosis RO Membrane Replacement -NSF Certificated","handle":"geekpure-75-gpd-reverse-osmosis-ro-membrane-replacement-nsf-certificated","description":"\u003ch3\u003eGeekpure 75 GPD Reverse Osmosis RO Membrane Replacement -NSF Certificated\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eOperation Specification: FEED WATER PRESSURE :35 - 100 PSI\nTEMPERATE: 40 - 110°F\/5-45°C PH :3.0 -11.0 MAX TDS 1000 MG\/L TURBIDITY \u0026lt; 1.0\nNTU MAX SDI \u0026lt;4.0 HARDNESS \u0026lt; 5 GPG IRON \u0026lt;0.1 Life time :15-24months as your\nfeed water quality Shelf life: 2 years in original sealed package. Note: 1. DO\nNOT FREEZE. 2. Please keep flush new membrane 30 minutes. Because there is\nprotection material in it. then, TDS of pure water will be down to right\nlevel. 3. If you have chlorinated water, we recommend you use a\nCarbon\/Sediment Pre-Filter. The residual chlorine in municipal or city water\nwill destroy the membrane. if hardness is too high, we recommend you install\nwater softener before Ro unit. Why do you choose Reverse Osmosis Filtration?\nWhy Hidrotek brand ? HIGH EFFICIENT FILTRATION HIDROTEK Ro membrane rejects\nimpurities down to 0.0001 micron.High permeated flow and stable salt\nrejection. Removes up to 98% of contaminants in water (Minimum Rejection 96%).\nit can remove heavy metal (primarily fluoride,calcium, magnesium, lead and\nnitrates) and any other 1000+ contaminants from source water Universal\nstandard size ​Standard size ( Membrane Dimensions: 11. 75\" Overall Length, 1.\n75\" Diameter), Fits all Standard 2\" ID Membrane housing.HIDROTEK supreme\nquality water filters are universal industry standard size and fit most\nresidential Reverse Osmosis Systems and water filtration systems Wastewater\nratio is 1:2 NSF certificated Thin-film composite RO membrane filters with\nhigher water production rate. 2 gallons waste water will be produced for every\ngallon pure water. Read more More valuable information: Question: What is\ndimension of the Ro membrane? Answer: It is standard size ( Membrane\nDimensions: 11. 75\" Overall Length, 1. 75\" Diameter), and Fits all Standard 2\"\nID Membrane Housings. Question:What is the life time? Answer:Our suggestion is\n24 months for most tap water (200-500 ppm).usually, you replace membrane\ndepends on usage amount and feed water quality. if tap water is very good\nquality (200 ppm or less), you may replace the membrane per 36 months. if hard\nwater area, someone replace membrane 6 months or 12 months. it is time to\nreplace new one if flow rate is too less or membrane is cloged. Question:Could\ni use it if my water Total Dissolved Solids is over 1000 ppm or very hard well\nwater? Answer: Yes, you can use it. even TDS reach 2000 ppm. but you should\nreplace membrane every 12 months or more frequently .less 1000 ppm is our\nsuggestion. Question:Can this be used for brackish water(5000 ppm) or ocean\nwater with high salinity(35000 ppm)? Answer:No. it is just designed for\nresidential tap water use. if you need Ro membrane for brackish water or ocean\nwater and industrial use, Geekpure can provide too, please send email to us.\nQuestion:What is in the box? Answer: Just RO membrane in the box. if you need\nmembrane housing, wrench and flow restrictor ,please buy it separated.\nDifferent temperature,different water pressure and feed water quality, the\nproduct water capacity and pure water quality is different. That is reason we\nfeel low pure water capacity in the winter, but higher in the summer. Lab test\ncondition : feed water pressure: 70 psi. work temperature: 77 F or 25 C. Nacl\nconcentration: 250 ppm. recovery: 15%. Read more How to replace Ro membrane?\n1.Remove the tube from the fitting and twist off the housing cap with wrench.\n2.You should pull out old membrane before step 2 when you replace new\nmembrane.(you may use pliers if necessary.) 3.Push the new membrane into\nhousing. 4.Put the housing cap back and tighten it. and connect concern\nfitting and tube. Read more DI Filter Membrane Housing 1-5 Stage Ro\nReplacement Filter Set 1 GPM 6W UV Filter Faucet Water Filter Alkaline Filter\nFeatures : Ro pure water TDS close to 0 ppm Membrane housing for 50 gpd -150\ngpd standard 1.8\"x12\" membrane. if your membrane is not standard, please buy\nthe housing together Universal Compatible standard 10\" reverse osmosis\nreplacement cartridges set 6th stage for Ro system,1 GPD UV Filter Advanced\n2-Stage Faucet Water Filter for Kitchen and Bathroom Removes Chlorine Taste \u0026amp;\nOdor, Sediment, Rust Particles 6th stage for Ro system,adjust PH value to\n7.5-9 (Ro water is about 5-6)\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eHigh Efficient-75 GPD Ro membrane,Rejects impurities down to 0.0001 micron,Removes Heavy Metal,Arsenic,Lead,Mercury,Fluoride and more 1000+ contaminants from source water\u003c\/li\u003e\n \u003cli\u003eHigh Quality - NSF\/ANSI Standard 58 certificated.Polyamide film composite material,food grade ,BPA free\u003c\/li\u003e\n \u003cli\u003eLife Span-It depends on usage amount and feed water quality. Usually,24 months or 35,000 Gallons pure water for most tap water (200-500 ppm)\u003c\/li\u003e\n \u003cli\u003eFriendly Design, Easy installation. It is suitable for most Reverse Osmosis Water Filtration System.Please note to flush new membrane 30 minutes\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-03-19T00:40:59+11:00","created_at":"2022-03-19T00:40:59+11:00","vendor":"Geekpure","type":"Water Filtration Replacement Parts","tags":["auspowers_batchone"],"price":14300,"price_min":14300,"price_max":14300,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41335081337012,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B074W72NNW","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Geekpure 75 GPD Reverse Osmosis RO Membrane Replacement -NSF Certificated","public_title":null,"options":["Default Title"],"price":14300,"weight":170,"compare_at_price":null,"inventory_management":null,"barcode":"680577668287","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B074W72NNW.jpg?v=1648571764","\/\/auspowers.com\/cdn\/shop\/products\/71QLLoNFCdL.jpg?v=1647610860","\/\/auspowers.com\/cdn\/shop\/products\/71eQmE3Y2AL_0671cf87-9600-4520-8347-148c7c253e5f.jpg?v=1647610860","\/\/auspowers.com\/cdn\/shop\/products\/7151zhJWVJL_35f53644-2735-49cd-ab3e-1b7227678055.jpg?v=1647610860","\/\/auspowers.com\/cdn\/shop\/products\/81pIknayMoL_7462bd33-a117-4417-803e-0af2dba605ac.jpg?v=1647610860"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B074W72NNW.jpg?v=1648571764","options":["Title"],"media":[{"alt":"[Australia - AusPower] - Geekpure 75 GPD Reverse Osmosis RO Membrane Replacement -NSF Certificated ","id":25349979111604,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B074W72NNW.jpg?v=1648571764"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B074W72NNW.jpg?v=1648571764","width":1500},{"alt":"[Australia - AusPower] - Geekpure 75 GPD Reverse Osmosis RO Membrane Replacement -NSF Certificated ","id":25204511867060,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71QLLoNFCdL.jpg?v=1647610860"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71QLLoNFCdL.jpg?v=1647610860","width":1500},{"alt":"[Australia - AusPower] - Geekpure 75 GPD Reverse Osmosis RO Membrane Replacement -NSF Certificated ","id":25204511899828,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71eQmE3Y2AL_0671cf87-9600-4520-8347-148c7c253e5f.jpg?v=1647610860"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71eQmE3Y2AL_0671cf87-9600-4520-8347-148c7c253e5f.jpg?v=1647610860","width":1500},{"alt":"[Australia - AusPower] - Geekpure 75 GPD Reverse Osmosis RO Membrane Replacement -NSF Certificated ","id":25204511932596,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/7151zhJWVJL_35f53644-2735-49cd-ab3e-1b7227678055.jpg?v=1647610860"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/7151zhJWVJL_35f53644-2735-49cd-ab3e-1b7227678055.jpg?v=1647610860","width":1200},{"alt":"[Australia - AusPower] - Geekpure 75 GPD Reverse Osmosis RO Membrane Replacement -NSF Certificated ","id":25204511965364,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/81pIknayMoL_7462bd33-a117-4417-803e-0af2dba605ac.jpg?v=1647610860"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/81pIknayMoL_7462bd33-a117-4417-803e-0af2dba605ac.jpg?v=1647610860","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eGeekpure 75 GPD Reverse Osmosis RO Membrane Replacement -NSF Certificated\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eOperation Specification: FEED WATER PRESSURE :35 - 100 PSI\nTEMPERATE: 40 - 110°F\/5-45°C PH :3.0 -11.0 MAX TDS 1000 MG\/L TURBIDITY \u0026lt; 1.0\nNTU MAX SDI \u0026lt;4.0 HARDNESS \u0026lt; 5 GPG IRON \u0026lt;0.1 Life time :15-24months as your\nfeed water quality Shelf life: 2 years in original sealed package. Note: 1. DO\nNOT FREEZE. 2. Please keep flush new membrane 30 minutes. Because there is\nprotection material in it. then, TDS of pure water will be down to right\nlevel. 3. If you have chlorinated water, we recommend you use a\nCarbon\/Sediment Pre-Filter. The residual chlorine in municipal or city water\nwill destroy the membrane. if hardness is too high, we recommend you install\nwater softener before Ro unit. Why do you choose Reverse Osmosis Filtration?\nWhy Hidrotek brand ? HIGH EFFICIENT FILTRATION HIDROTEK Ro membrane rejects\nimpurities down to 0.0001 micron.High permeated flow and stable salt\nrejection. Removes up to 98% of contaminants in water (Minimum Rejection 96%).\nit can remove heavy metal (primarily fluoride,calcium, magnesium, lead and\nnitrates) and any other 1000+ contaminants from source water Universal\nstandard size ​Standard size ( Membrane Dimensions: 11. 75\" Overall Length, 1.\n75\" Diameter), Fits all Standard 2\" ID Membrane housing.HIDROTEK supreme\nquality water filters are universal industry standard size and fit most\nresidential Reverse Osmosis Systems and water filtration systems Wastewater\nratio is 1:2 NSF certificated Thin-film composite RO membrane filters with\nhigher water production rate. 2 gallons waste water will be produced for every\ngallon pure water. Read more More valuable information: Question: What is\ndimension of the Ro membrane? Answer: It is standard size ( Membrane\nDimensions: 11. 75\" Overall Length, 1. 75\" Diameter), and Fits all Standard 2\"\nID Membrane Housings. Question:What is the life time? Answer:Our suggestion is\n24 months for most tap water (200-500 ppm).usually, you replace membrane\ndepends on usage amount and feed water quality. if tap water is very good\nquality (200 ppm or less), you may replace the membrane per 36 months. if hard\nwater area, someone replace membrane 6 months or 12 months. it is time to\nreplace new one if flow rate is too less or membrane is cloged. Question:Could\ni use it if my water Total Dissolved Solids is over 1000 ppm or very hard well\nwater? Answer: Yes, you can use it. even TDS reach 2000 ppm. but you should\nreplace membrane every 12 months or more frequently .less 1000 ppm is our\nsuggestion. Question:Can this be used for brackish water(5000 ppm) or ocean\nwater with high salinity(35000 ppm)? Answer:No. it is just designed for\nresidential tap water use. if you need Ro membrane for brackish water or ocean\nwater and industrial use, Geekpure can provide too, please send email to us.\nQuestion:What is in the box? Answer: Just RO membrane in the box. if you need\nmembrane housing, wrench and flow restrictor ,please buy it separated.\nDifferent temperature,different water pressure and feed water quality, the\nproduct water capacity and pure water quality is different. That is reason we\nfeel low pure water capacity in the winter, but higher in the summer. Lab test\ncondition : feed water pressure: 70 psi. work temperature: 77 F or 25 C. Nacl\nconcentration: 250 ppm. recovery: 15%. Read more How to replace Ro membrane?\n1.Remove the tube from the fitting and twist off the housing cap with wrench.\n2.You should pull out old membrane before step 2 when you replace new\nmembrane.(you may use pliers if necessary.) 3.Push the new membrane into\nhousing. 4.Put the housing cap back and tighten it. and connect concern\nfitting and tube. Read more DI Filter Membrane Housing 1-5 Stage Ro\nReplacement Filter Set 1 GPM 6W UV Filter Faucet Water Filter Alkaline Filter\nFeatures : Ro pure water TDS close to 0 ppm Membrane housing for 50 gpd -150\ngpd standard 1.8\"x12\" membrane. if your membrane is not standard, please buy\nthe housing together Universal Compatible standard 10\" reverse osmosis\nreplacement cartridges set 6th stage for Ro system,1 GPD UV Filter Advanced\n2-Stage Faucet Water Filter for Kitchen and Bathroom Removes Chlorine Taste \u0026amp;\nOdor, Sediment, Rust Particles 6th stage for Ro system,adjust PH value to\n7.5-9 (Ro water is about 5-6)\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eHigh Efficient-75 GPD Ro membrane,Rejects impurities down to 0.0001 micron,Removes Heavy Metal,Arsenic,Lead,Mercury,Fluoride and more 1000+ contaminants from source water\u003c\/li\u003e\n \u003cli\u003eHigh Quality - NSF\/ANSI Standard 58 certificated.Polyamide film composite material,food grade ,BPA free\u003c\/li\u003e\n \u003cli\u003eLife Span-It depends on usage amount and feed water quality. Usually,24 months or 35,000 Gallons pure water for most tap water (200-500 ppm)\u003c\/li\u003e\n \u003cli\u003eFriendly Design, Easy installation. It is suitable for most Reverse Osmosis Water Filtration System.Please note to flush new membrane 30 minutes\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

Geekpure 75 GPD Reverse Osmosis RO Membrane Replacement -NSF Certificated

In Stock. Leaves warehouse within 2 - 3 business days

$143.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Geekpure 75 GPD Reverse Osmosis RO Membrane Replacement -NSF Certificated

Operation Specification: FEED WATER PRESSURE :35 - 100 PSI TEMPERATE: 40 - 110°F/5-45°C PH :3.0 -11.0 MAX TDS 1000 MG/L TURBIDITY < 1.0 NTU MAX SDI <4.0 HARDNESS < 5 GPG IRON <0.1 Life time :15-24months as your feed water quality Shelf life: 2 years in original sealed package. Note: 1. DO NOT FREEZE. 2. Please keep flush new membrane 30 minutes. Because there is protection material in it. then, TDS of pure water will be down to right level. 3. If you have chlorinated water, we recommend you use a Carbon/Sediment Pre-Filter. The residual chlorine in municipal or city water will destroy the membrane. if hardness is too high, we recommend you install water softener before Ro unit. Why do you choose Reverse Osmosis Filtration? Why Hidrotek brand ? HIGH EFFICIENT FILTRATION HIDROTEK Ro membrane rejects impurities down to 0.0001 micron.High permeated flow and stable salt rejection. Removes up to 98% of contaminants in water (Minimum Rejection 96%). it can remove heavy metal (primarily fluoride,calcium, magnesium, lead and nitrates) and any other 1000+ contaminants from source water Universal standard size ​Standard size ( Membrane Dimensions: 11. 75" Overall Length, 1. 75" Diameter), Fits all Standard 2" ID Membrane housing.HIDROTEK supreme quality water filters are universal industry standard size and fit most residential Reverse Osmosis Systems and water filtration systems Wastewater ratio is 1:2 NSF certificated Thin-film composite RO membrane filters with higher water production rate. 2 gallons waste water will be produced for every gallon pure water. Read more More valuable information: Question: What is dimension of the Ro membrane? Answer: It is standard size ( Membrane Dimensions: 11. 75" Overall Length, 1. 75" Diameter), and Fits all Standard 2" ID Membrane Housings. Question:What is the life time? Answer:Our suggestion is 24 months for most tap water (200-500 ppm).usually, you replace membrane depends on usage amount and feed water quality. if tap water is very good quality (200 ppm or less), you may replace the membrane per 36 months. if hard water area, someone replace membrane 6 months or 12 months. it is time to replace new one if flow rate is too less or membrane is cloged. Question:Could i use it if my water Total Dissolved Solids is over 1000 ppm or very hard well water? Answer: Yes, you can use it. even TDS reach 2000 ppm. but you should replace membrane every 12 months or more frequently .less 1000 ppm is our suggestion. Question:Can this be used for brackish water(5000 ppm) or ocean water with high salinity(35000 ppm)? Answer:No. it is just designed for residential tap water use. if you need Ro membrane for brackish water or ocean water and industrial use, Geekpure can provide too, please send email to us. Question:What is in the box? Answer: Just RO membrane in the box. if you need membrane housing, wrench and flow restrictor ,please buy it separated. Different temperature,different water pressure and feed water quality, the product water capacity and pure water quality is different. That is reason we feel low pure water capacity in the winter, but higher in the summer. Lab test condition : feed water pressure: 70 psi. work temperature: 77 F or 25 C. Nacl concentration: 250 ppm. recovery: 15%. Read more How to replace Ro membrane? 1.Remove the tube from the fitting and twist off the housing cap with wrench. 2.You should pull out old membrane before step 2 when you replace new membrane.(you may use pliers if necessary.) 3.Push the new membrane into housing. 4.Put the housing cap back and tighten it. and connect concern fitting and tube. Read more DI Filter Membrane Housing 1-5 Stage Ro Replacement Filter Set 1 GPM 6W UV Filter Faucet Water Filter Alkaline Filter Features : Ro pure water TDS close to 0 ppm Membrane housing for 50 gpd -150 gpd standard 1.8"x12" membrane. if your membrane is not standard, please buy the housing together Universal Compatible standard 10" reverse osmosis replacement cartridges set 6th stage for Ro system,1 GPD UV Filter Advanced 2-Stage Faucet Water Filter for Kitchen and Bathroom Removes Chlorine Taste & Odor, Sediment, Rust Particles 6th stage for Ro system,adjust PH value to 7.5-9 (Ro water is about 5-6)

Product Features

  • High Efficient-75 GPD Ro membrane,Rejects impurities down to 0.0001 micron,Removes Heavy Metal,Arsenic,Lead,Mercury,Fluoride and more 1000+ contaminants from source water
  • High Quality - NSF/ANSI Standard 58 certificated.Polyamide film composite material,food grade ,BPA free
  • Life Span-It depends on usage amount and feed water quality. Usually,24 months or 35,000 Gallons pure water for most tap water (200-500 ppm)
  • Friendly Design, Easy installation. It is suitable for most Reverse Osmosis Water Filtration System.Please note to flush new membrane 30 minutes

Related Products