{"id":7086834286772,"title":"FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino","handle":"fainwan-1pack-digital-particle-concentration-laser-sensor-pms5003-pm2-5-pm10-cable-air-quality-detection-sensor-dust-sensor-air-conditioning-monitor-module-compatible-with-ar-duino","description":"\u003ch3\u003eFainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eInstallation Attentions Metal shell is connected to the GND so be careful not\nto let it shorted with the other parts of circuit except GND. The best way of\ninstall is making the plane of inset and outset closely to the plane of the\nhost. Or some shield should be placed between inset and outset in order to\nprevent the air flow from inner loop. The blowhole in the shell of the host\nshould not be smaller than the inset. The sensor should not be installed in\nthe air flow way of the air cleaner or should be shielded by some structure.\nThe sensor should be installed at least 20cm higher than the grand in order to\nprevent it from blocking by the floc dust. Do not break up the sensor. M2\nself-tapping strew should be used to fix the sensor but it should not be\ndeeper than 5mm into the sensor. Circuit Attentions DC 5V power supply is\nneeded because the FAN should be driven by 5V. But the high level of data pin\nis 3.3V. Level conversion unit should be used if the power of host MCU is 5V.\nThe SET and RESET pins are pulled up inside so they should not be connected if\nwithout usage. PIN7 and PIN8 should not be connected. Stable data should be\ngot at least 30 seconds after the sensor wakeup from the sleep mode because of\nthe fan’s performance.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eMeasuring range: 0.3~1.0;1.0~2.5;2.5~10 (um)\u003c\/li\u003e\n \u003cli\u003eDC Supply Voltage: 5.0(V) ,Maximum Operating Current: 120(mA)\u003c\/li\u003e\n \u003cli\u003ePMS5003 (G5) is a digital versatile particulate matter concentration sensor can be used to get the quality and quantity in the unit volume of suspended particulate matter in the air, and a digital interface in the form of output.\u003c\/li\u003e\n \u003cli\u003eThe same side air inlet and outlet simplifies the structural design and dustproof sensor structure design. and Dust prevention sensor structure design.\u003c\/li\u003e\n \u003cli\u003ePackage Includes:1pcs Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-03-19T05:22:33+11:00","created_at":"2022-03-19T05:22:33+11:00","vendor":"FainWan","type":"Indoor Air Quality Meters","tags":["auspowers_batchone"],"price":16100,"price_min":16100,"price_max":16100,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41336001462452,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B09JZCGBFC","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino","public_title":null,"options":["Default Title"],"price":16100,"weight":100,"compare_at_price":null,"inventory_management":null,"barcode":"0755867230304","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B09JZCGBFC.jpg?v=1648583121","\/\/auspowers.com\/cdn\/shop\/products\/51YitZgxJtL.jpg?v=1647627753","\/\/auspowers.com\/cdn\/shop\/products\/51w00MH5OfL.jpg?v=1647627753","\/\/auspowers.com\/cdn\/shop\/products\/51p_bmlVJpL.jpg?v=1647627753","\/\/auspowers.com\/cdn\/shop\/products\/518flLTMShL.jpg?v=1647627753","\/\/auspowers.com\/cdn\/shop\/products\/51ssTbOXT4L.jpg?v=1647627753","\/\/auspowers.com\/cdn\/shop\/products\/51xIDwVWeDL.jpg?v=1647627753","\/\/auspowers.com\/cdn\/shop\/products\/51eLq6t6W3L.jpg?v=1647627753"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B09JZCGBFC.jpg?v=1648583121","options":["Title"],"media":[{"alt":"[Australia - AusPower] - FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino ","id":25352078819508,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B09JZCGBFC.jpg?v=1648583121"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B09JZCGBFC.jpg?v=1648583121","width":1200},{"alt":"[Australia - AusPower] - FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino ","id":25207565418676,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51YitZgxJtL.jpg?v=1647627753"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51YitZgxJtL.jpg?v=1647627753","width":1200},{"alt":"[Australia - AusPower] - FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino ","id":25207565451444,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51w00MH5OfL.jpg?v=1647627753"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51w00MH5OfL.jpg?v=1647627753","width":1200},{"alt":"[Australia - AusPower] - FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino ","id":25207565484212,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51p_bmlVJpL.jpg?v=1647627753"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51p_bmlVJpL.jpg?v=1647627753","width":1200},{"alt":"[Australia - AusPower] - FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino ","id":25207565516980,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/518flLTMShL.jpg?v=1647627753"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/518flLTMShL.jpg?v=1647627753","width":1200},{"alt":"[Australia - AusPower] - FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino ","id":25207565549748,"position":6,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51ssTbOXT4L.jpg?v=1647627753"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51ssTbOXT4L.jpg?v=1647627753","width":1200},{"alt":"[Australia - AusPower] - FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino ","id":25207565582516,"position":7,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51xIDwVWeDL.jpg?v=1647627753"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51xIDwVWeDL.jpg?v=1647627753","width":1200},{"alt":"[Australia - AusPower] - FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino ","id":25207565615284,"position":8,"preview_image":{"aspect_ratio":1.0,"height":1200,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51eLq6t6W3L.jpg?v=1647627753"},"aspect_ratio":1.0,"height":1200,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51eLq6t6W3L.jpg?v=1647627753","width":1200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eFainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eInstallation Attentions Metal shell is connected to the GND so be careful not\nto let it shorted with the other parts of circuit except GND. The best way of\ninstall is making the plane of inset and outset closely to the plane of the\nhost. Or some shield should be placed between inset and outset in order to\nprevent the air flow from inner loop. The blowhole in the shell of the host\nshould not be smaller than the inset. The sensor should not be installed in\nthe air flow way of the air cleaner or should be shielded by some structure.\nThe sensor should be installed at least 20cm higher than the grand in order to\nprevent it from blocking by the floc dust. Do not break up the sensor. M2\nself-tapping strew should be used to fix the sensor but it should not be\ndeeper than 5mm into the sensor. Circuit Attentions DC 5V power supply is\nneeded because the FAN should be driven by 5V. But the high level of data pin\nis 3.3V. Level conversion unit should be used if the power of host MCU is 5V.\nThe SET and RESET pins are pulled up inside so they should not be connected if\nwithout usage. PIN7 and PIN8 should not be connected. Stable data should be\ngot at least 30 seconds after the sensor wakeup from the sleep mode because of\nthe fan’s performance.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eMeasuring range: 0.3~1.0;1.0~2.5;2.5~10 (um)\u003c\/li\u003e\n \u003cli\u003eDC Supply Voltage: 5.0(V) ,Maximum Operating Current: 120(mA)\u003c\/li\u003e\n \u003cli\u003ePMS5003 (G5) is a digital versatile particulate matter concentration sensor can be used to get the quality and quantity in the unit volume of suspended particulate matter in the air, and a digital interface in the form of output.\u003c\/li\u003e\n \u003cli\u003eThe same side air inlet and outlet simplifies the structural design and dustproof sensor structure design. and Dust prevention sensor structure design.\u003c\/li\u003e\n \u003cli\u003ePackage Includes:1pcs Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino

In Stock. Leaves warehouse within 2 - 3 business days

$161.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

FainWan 1Pack Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable Air Quality Detection Sensor Dust Sensor Air Conditioning Monitor Module Compatible with Ar-duino

Installation Attentions Metal shell is connected to the GND so be careful not to let it shorted with the other parts of circuit except GND. The best way of install is making the plane of inset and outset closely to the plane of the host. Or some shield should be placed between inset and outset in order to prevent the air flow from inner loop. The blowhole in the shell of the host should not be smaller than the inset. The sensor should not be installed in the air flow way of the air cleaner or should be shielded by some structure. The sensor should be installed at least 20cm higher than the grand in order to prevent it from blocking by the floc dust. Do not break up the sensor. M2 self-tapping strew should be used to fix the sensor but it should not be deeper than 5mm into the sensor. Circuit Attentions DC 5V power supply is needed because the FAN should be driven by 5V. But the high level of data pin is 3.3V. Level conversion unit should be used if the power of host MCU is 5V. The SET and RESET pins are pulled up inside so they should not be connected if without usage. PIN7 and PIN8 should not be connected. Stable data should be got at least 30 seconds after the sensor wakeup from the sleep mode because of the fan’s performance.

Product Features

  • Measuring range: 0.3~1.0;1.0~2.5;2.5~10 (um)
  • DC Supply Voltage: 5.0(V) ,Maximum Operating Current: 120(mA)
  • PMS5003 (G5) is a digital versatile particulate matter concentration sensor can be used to get the quality and quantity in the unit volume of suspended particulate matter in the air, and a digital interface in the form of output.
  • The same side air inlet and outlet simplifies the structural design and dustproof sensor structure design. and Dust prevention sensor structure design.
  • Package Includes:1pcs Digital Particle Concentration Laser Sensor PMS5003 PM2.5 PM10+Cable

Related Products