Delay Off Relay Module 10-16V 12V DC Time Relay Module Double Pole Double Throw DPDT 2 Channel Output Timer Switch for Water/Air Flow Interruption Monitoring
Delay Off Relay Module 10-16V 12V DC Time Relay Module Double Pole Double Throw DPDT 2 Channel Output Timer Switch for Water/Air Flow Interruption Monitoring
Read more Delay Off Relay Module Package: 1 x Delay Relay Module Application: Use with limit switch and induction switch to achieve:1. Automatically close the door after timeout2. Assembly line product interruption monitoring3. Water/air flow interruption monitoring Specification: Item Type: Delay Off Relay ModuleVoltage: 12V DC (10-16V)Power Consumption: <1.0WOutput: Passive Output (dry contact), two sets of relay NO + NC output. Do not exceed 5A in each group.Life: 100,000 actionsInput: Voltage signal, valid signal above 1.5V, current needs at least 0.1mA Terminal V+: Power supply +GND: Power supply -, also the reference GND for the signal voltageIN: Signal voltage input, low level below 1V, high level above 1.5V, and uncertainty in the middle. Withstands up to 30VNO1: Relay NO contact 1NC1: Relay NC contact 1COM1: Relay contact common terminal 1NO2: Relay NO contact 2NC2: Relay NC contact 2COM2: Relay contact common terminal 2 Read more Time Range Setting: When the selector switch is set to 30 position, it means that 0-30 is adjustableWhen the selector switch is set to the 300 position, it means that 0-300 is adjustable Time Value Adjustment: Turn the adjustable resistor counterclockwise to decrease the time and clockwise to increase the time Time Unit Setting : When the selector switch is set to the Sec position, the unit is: secondWhen the selector switch is set to the Min position, the unit is: minute Example: Requires a delay of 50 minutes:1. Set time range at 300 position2. Set time unit at Min position3. Adjust the adjustable resistor to the 50 position. Note: The adjustment of the potentiometer can also be quickly adjusted with the multimeter voltage file. For example, if the range is 30, it needs to be adjusted to 12, then the voltage can be adjusted to 2. t=Ut/530=2.0V / 5.0V 30 =12 Ut is the voltage measured by the multimeter, 30 is the range selected by the selector switch, and can also be selected to 300
Product Features
- Power-off delay disconnection, there is signal - ON, no signal - delay OFF.
- Double output contacts.
- Each channel maximum current is 5A.
- Adjustable time range 0-30/0-300 and time unit second/minute.
- Rotate the adjustable resistor to setup delay time.