{"id":7135951782068,"title":"1\/4\" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (Standard USA Pipe Thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid.","handle":"1-4-npt-brass-electric-solenoid-valve-12vdc-normally-closed-viton-standard-usa-pipe-thread-solid-brass-direct-acting-viton-gasket-solenoid-valve-by-u-s-solid","description":"\u003ch3\u003e1\/4\" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (Standard USA Pipe Thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid.\u003c\/h3\u003e\n\u003cp id=\"b\"\u003e1\/4\" NPT Brass Electric Solenoid Valve 12VDC Normally\nClosed VITON (standard USA pipe thread). Solid Brass, Direct Acting, Viton\nGasket Solenoid Valve by U.S. Solid. U. S. Solid Normally Closed Electric\nSolenoid Valve; 1\/4”ports, brass body, VITON seal, 12 volt DC, for air, water,\nor fuel U.S. Solid normally closed (N\/C) electric solenoid valve is\nconstructed with a durable brass body, two-way inlet and outlet ports with one\nquarter inch (1\/4\") female threaded (NPT) connections, and heat and oil\nresistant Viton gasket.The direct current coil energizes at 12 volts\nDC;voltage range +- 10%. 12 Watt power rating. Direct lift valve operates from\n0 PSI to a maximum pressure of 145 PSI (0 MPa to 1.0 MPa). Operational\npressure range for water: 0 to 101 PSI; for oil: 0 to 72 PSI; for air or\ngases: 0 to 101 PSI. 1\/4\" (2.5 mm) flow aperture permits a unidirectional flow\ncapacity of 0.23 gallons per minute (GPM) of water at 60°Fwith a pressure drop\nof 1 PSI (0.6 Cv). Operational temperature range (steady state) -10° to 120°\nCelsius (14° to 248° Fahrenheit). Suitable for outdoor use; not for use\nunderwater. Suitable for use with hot or cold water, gas, air, very low\nviscosity fluids (\u0026lt; 20 cst), oils and hydrocarbons, e.g., gasoline, kerosene,\nor diesel fuel. Valve is not intended to be energized continuously for more\nthan 8 hours. This can lead to burnout of the coil, and malfunctioning of the\nvalve. In cases where this is necessary, it is recommended user install a\ncomputer fan to keep valve cool. Direction of the flow (most U.S. Solid Valves\nare UNIDIRECTIONAL) FLOW DIRECTION Make note of the arrow on your valve. Most\nU.S. Solid valves are unidirectional. This means they are intended for flow in\none direction only, in the direction of the arrow. See Figure 1 for location\nof arrow. If connected in opposite direction, the valve will not actuate\nproperly (will not close for Normally Closed valves). Additionally, be sure\nthe medium passing through is filtered. If not, particles will cling to the\ngasket over time, which can cause it to not seal properly. National Pipe\nThread, Standard USA thread (use Teflon tape to seal) THREADING U.S. Solid\nValves follow National Standards for pipe thread. In the U.S.A. we use NPT,\nwhile in England we use BSPT. We recommend use of Teflon tape to ensure seal\nof the NPT threading, as shown in Figure 2. The tapered male and female thread\nare forming angled surfaces that with increased torque squeeze the Teflon tape\nthat results in a tight seal. It is suitable to liquids, gases and even for\nhigh vacuum. NPT seal is known to be use even in UHV (Ultra High Vacuum)\napplications. Note that this particular valve is not pneumatic by design but\nnumerous of our customers use them for compressed gasses. POLARITY For valves\nwith 2 wires, the valve will actuate regardless of which terminal each wire is\nconnected to (+ or -). Some units, like those pictured to the left, include a\nground wire. Open up the connector and look for the ground symbol, shown in\nthe corner of Figure 3. For valves with a ground wire, please be sure to\nground the valve. For the other two wires, the valve will actuate regardless\nof which terminal each wire is connected to (+ or -). OVERHEATING These valves\nare not intended to be energized for more than 8 hours continously. While most\ndo not have more than 18W of power, the coils are in a contained area, and can\nburnout if energized for too long. If necessary to energize continously for\nextended periods, we recommend a computer fan to keep the coil cool. GASOLINE\nWARNING Note whether your solenoid valve has a VITON gasket, NBR gasket, or\nanother type. NBR gaskets are not intended for use with gasoline, kerosene, or\nother petroleum products. If your valve is needed for these, please purchase a\nvalve with a VITON gasket. PRESSURE All solenoid valves need some pressure to\nactuate. This is especially true of pilot or indirectly operated valves.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eConstructed of industrial grade brass, this valve is corrosion resistant, more conducive for welding, optimal for higher temperature projects, and can be used with gasoline, diesel fuel, kerosene oil, natural gas, air etc. Due to the chemical composition of brass, this valve should NOT be used with projects involving drinking water or other water projects.\u003c\/li\u003e\n \u003cli\u003eThis valve was manufactured with a VITON seal. VITON is the most durable and high performance rubber material with the ability to resist high temperatures and corrosive chemicals and other fluids like gasoline, diesel fuel, oils, and lubricants.\u003c\/li\u003e\n \u003cli\u003eThis highly responsive valve will open and close in less than 1 second when actuated; meaning it will open or close the flow instantaneously when energized or de-energized. Also, our U.S. SOLID engineers have determined that the life cycle of this valve is well over a million cycles with proper operating conditions and maintenance.\u003c\/li\u003e\n \u003cli\u003ePLEASE NOTE: This valve is NOT a continuous duty valve and should NOT be in continuous use for more than 8 hours in a single cycle; to do so will shorten the life of the valve and may cause the core of the valve to burn out. If you need a continuous duty valve for your project please search for our U.S. SOLID Motorized Ball Valves.\u003c\/li\u003e\n \u003cli\u003eAs with all U.S. SOLID products, this valve comes with a ONE YEAR WARRANTY. If the valve does become defective within the first year of purchase, U.S. SOLID will gladly replace it.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-05-17T22:17:35+10:00","created_at":"2022-05-17T22:17:40+10:00","vendor":"U.S. Solid","type":"Solenoid Valves","tags":["industrial"],"price":15100,"price_min":15100,"price_max":15100,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41502239883444,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B00APDNPXG","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"1\/4\" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (Standard USA Pipe Thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid.","public_title":null,"options":["Default Title"],"price":15100,"weight":320,"compare_at_price":null,"inventory_management":null,"barcode":"853996003506","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B00APDNPXG.jpg?v=1652858314","\/\/auspowers.com\/cdn\/shop\/products\/71TRASdLYoL.jpg?v=1652789860","\/\/auspowers.com\/cdn\/shop\/products\/71B3oVz2w1L.jpg?v=1652789860","\/\/auspowers.com\/cdn\/shop\/products\/71POp3sieBL.jpg?v=1652789860","\/\/auspowers.com\/cdn\/shop\/products\/81mnfpAkIXL.jpg?v=1652789860"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B00APDNPXG.jpg?v=1652858314","options":["Title"],"media":[{"alt":"[Australia - AusPower] - 1\/4\" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (Standard USA Pipe Thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid. ","id":25893536235700,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B00APDNPXG.jpg?v=1652858314"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B00APDNPXG.jpg?v=1652858314","width":1500},{"alt":"[Australia - AusPower] - 1\/4\" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (Standard USA Pipe Thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid. ","id":25886572609716,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71TRASdLYoL.jpg?v=1652789860"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71TRASdLYoL.jpg?v=1652789860","width":1500},{"alt":"[Australia - AusPower] - 1\/4\" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (Standard USA Pipe Thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid. ","id":25886572642484,"position":3,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71B3oVz2w1L.jpg?v=1652789860"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71B3oVz2w1L.jpg?v=1652789860","width":1500},{"alt":"[Australia - AusPower] - 1\/4\" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (Standard USA Pipe Thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid. ","id":25886572675252,"position":4,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71POp3sieBL.jpg?v=1652789860"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71POp3sieBL.jpg?v=1652789860","width":1500},{"alt":"[Australia - AusPower] - 1\/4\" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (Standard USA Pipe Thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid. ","id":25886572708020,"position":5,"preview_image":{"aspect_ratio":1.0,"height":1500,"width":1500,"src":"\/\/auspowers.com\/cdn\/shop\/products\/81mnfpAkIXL.jpg?v=1652789860"},"aspect_ratio":1.0,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/81mnfpAkIXL.jpg?v=1652789860","width":1500}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003e1\/4\" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (Standard USA Pipe Thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid.\u003c\/h3\u003e\n\u003cp id=\"b\"\u003e1\/4\" NPT Brass Electric Solenoid Valve 12VDC Normally\nClosed VITON (standard USA pipe thread). Solid Brass, Direct Acting, Viton\nGasket Solenoid Valve by U.S. Solid. U. S. Solid Normally Closed Electric\nSolenoid Valve; 1\/4”ports, brass body, VITON seal, 12 volt DC, for air, water,\nor fuel U.S. Solid normally closed (N\/C) electric solenoid valve is\nconstructed with a durable brass body, two-way inlet and outlet ports with one\nquarter inch (1\/4\") female threaded (NPT) connections, and heat and oil\nresistant Viton gasket.The direct current coil energizes at 12 volts\nDC;voltage range +- 10%. 12 Watt power rating. Direct lift valve operates from\n0 PSI to a maximum pressure of 145 PSI (0 MPa to 1.0 MPa). Operational\npressure range for water: 0 to 101 PSI; for oil: 0 to 72 PSI; for air or\ngases: 0 to 101 PSI. 1\/4\" (2.5 mm) flow aperture permits a unidirectional flow\ncapacity of 0.23 gallons per minute (GPM) of water at 60°Fwith a pressure drop\nof 1 PSI (0.6 Cv). Operational temperature range (steady state) -10° to 120°\nCelsius (14° to 248° Fahrenheit). Suitable for outdoor use; not for use\nunderwater. Suitable for use with hot or cold water, gas, air, very low\nviscosity fluids (\u0026lt; 20 cst), oils and hydrocarbons, e.g., gasoline, kerosene,\nor diesel fuel. Valve is not intended to be energized continuously for more\nthan 8 hours. This can lead to burnout of the coil, and malfunctioning of the\nvalve. In cases where this is necessary, it is recommended user install a\ncomputer fan to keep valve cool. Direction of the flow (most U.S. Solid Valves\nare UNIDIRECTIONAL) FLOW DIRECTION Make note of the arrow on your valve. Most\nU.S. Solid valves are unidirectional. This means they are intended for flow in\none direction only, in the direction of the arrow. See Figure 1 for location\nof arrow. If connected in opposite direction, the valve will not actuate\nproperly (will not close for Normally Closed valves). Additionally, be sure\nthe medium passing through is filtered. If not, particles will cling to the\ngasket over time, which can cause it to not seal properly. National Pipe\nThread, Standard USA thread (use Teflon tape to seal) THREADING U.S. Solid\nValves follow National Standards for pipe thread. In the U.S.A. we use NPT,\nwhile in England we use BSPT. We recommend use of Teflon tape to ensure seal\nof the NPT threading, as shown in Figure 2. The tapered male and female thread\nare forming angled surfaces that with increased torque squeeze the Teflon tape\nthat results in a tight seal. It is suitable to liquids, gases and even for\nhigh vacuum. NPT seal is known to be use even in UHV (Ultra High Vacuum)\napplications. Note that this particular valve is not pneumatic by design but\nnumerous of our customers use them for compressed gasses. POLARITY For valves\nwith 2 wires, the valve will actuate regardless of which terminal each wire is\nconnected to (+ or -). Some units, like those pictured to the left, include a\nground wire. Open up the connector and look for the ground symbol, shown in\nthe corner of Figure 3. For valves with a ground wire, please be sure to\nground the valve. For the other two wires, the valve will actuate regardless\nof which terminal each wire is connected to (+ or -). OVERHEATING These valves\nare not intended to be energized for more than 8 hours continously. While most\ndo not have more than 18W of power, the coils are in a contained area, and can\nburnout if energized for too long. If necessary to energize continously for\nextended periods, we recommend a computer fan to keep the coil cool. GASOLINE\nWARNING Note whether your solenoid valve has a VITON gasket, NBR gasket, or\nanother type. NBR gaskets are not intended for use with gasoline, kerosene, or\nother petroleum products. If your valve is needed for these, please purchase a\nvalve with a VITON gasket. PRESSURE All solenoid valves need some pressure to\nactuate. This is especially true of pilot or indirectly operated valves.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eConstructed of industrial grade brass, this valve is corrosion resistant, more conducive for welding, optimal for higher temperature projects, and can be used with gasoline, diesel fuel, kerosene oil, natural gas, air etc. Due to the chemical composition of brass, this valve should NOT be used with projects involving drinking water or other water projects.\u003c\/li\u003e\n \u003cli\u003eThis valve was manufactured with a VITON seal. VITON is the most durable and high performance rubber material with the ability to resist high temperatures and corrosive chemicals and other fluids like gasoline, diesel fuel, oils, and lubricants.\u003c\/li\u003e\n \u003cli\u003eThis highly responsive valve will open and close in less than 1 second when actuated; meaning it will open or close the flow instantaneously when energized or de-energized. Also, our U.S. SOLID engineers have determined that the life cycle of this valve is well over a million cycles with proper operating conditions and maintenance.\u003c\/li\u003e\n \u003cli\u003ePLEASE NOTE: This valve is NOT a continuous duty valve and should NOT be in continuous use for more than 8 hours in a single cycle; to do so will shorten the life of the valve and may cause the core of the valve to burn out. If you need a continuous duty valve for your project please search for our U.S. SOLID Motorized Ball Valves.\u003c\/li\u003e\n \u003cli\u003eAs with all U.S. SOLID products, this valve comes with a ONE YEAR WARRANTY. If the valve does become defective within the first year of purchase, U.S. SOLID will gladly replace it.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

1/4" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (Standard USA Pipe Thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid.

In Stock. Leaves warehouse within 2 - 3 business days

$151.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

1/4" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (Standard USA Pipe Thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid.

1/4" NPT Brass Electric Solenoid Valve 12VDC Normally Closed VITON (standard USA pipe thread). Solid Brass, Direct Acting, Viton Gasket Solenoid Valve by U.S. Solid. U. S. Solid Normally Closed Electric Solenoid Valve; 1/4”ports, brass body, VITON seal, 12 volt DC, for air, water, or fuel U.S. Solid normally closed (N/C) electric solenoid valve is constructed with a durable brass body, two-way inlet and outlet ports with one quarter inch (1/4") female threaded (NPT) connections, and heat and oil resistant Viton gasket.The direct current coil energizes at 12 volts DC;voltage range +- 10%. 12 Watt power rating. Direct lift valve operates from 0 PSI to a maximum pressure of 145 PSI (0 MPa to 1.0 MPa). Operational pressure range for water: 0 to 101 PSI; for oil: 0 to 72 PSI; for air or gases: 0 to 101 PSI. 1/4" (2.5 mm) flow aperture permits a unidirectional flow capacity of 0.23 gallons per minute (GPM) of water at 60°Fwith a pressure drop of 1 PSI (0.6 Cv). Operational temperature range (steady state) -10° to 120° Celsius (14° to 248° Fahrenheit). Suitable for outdoor use; not for use underwater. Suitable for use with hot or cold water, gas, air, very low viscosity fluids (< 20 cst), oils and hydrocarbons, e.g., gasoline, kerosene, or diesel fuel. Valve is not intended to be energized continuously for more than 8 hours. This can lead to burnout of the coil, and malfunctioning of the valve. In cases where this is necessary, it is recommended user install a computer fan to keep valve cool. Direction of the flow (most U.S. Solid Valves are UNIDIRECTIONAL) FLOW DIRECTION Make note of the arrow on your valve. Most U.S. Solid valves are unidirectional. This means they are intended for flow in one direction only, in the direction of the arrow. See Figure 1 for location of arrow. If connected in opposite direction, the valve will not actuate properly (will not close for Normally Closed valves). Additionally, be sure the medium passing through is filtered. If not, particles will cling to the gasket over time, which can cause it to not seal properly. National Pipe Thread, Standard USA thread (use Teflon tape to seal) THREADING U.S. Solid Valves follow National Standards for pipe thread. In the U.S.A. we use NPT, while in England we use BSPT. We recommend use of Teflon tape to ensure seal of the NPT threading, as shown in Figure 2. The tapered male and female thread are forming angled surfaces that with increased torque squeeze the Teflon tape that results in a tight seal. It is suitable to liquids, gases and even for high vacuum. NPT seal is known to be use even in UHV (Ultra High Vacuum) applications. Note that this particular valve is not pneumatic by design but numerous of our customers use them for compressed gasses. POLARITY For valves with 2 wires, the valve will actuate regardless of which terminal each wire is connected to (+ or -). Some units, like those pictured to the left, include a ground wire. Open up the connector and look for the ground symbol, shown in the corner of Figure 3. For valves with a ground wire, please be sure to ground the valve. For the other two wires, the valve will actuate regardless of which terminal each wire is connected to (+ or -). OVERHEATING These valves are not intended to be energized for more than 8 hours continously. While most do not have more than 18W of power, the coils are in a contained area, and can burnout if energized for too long. If necessary to energize continously for extended periods, we recommend a computer fan to keep the coil cool. GASOLINE WARNING Note whether your solenoid valve has a VITON gasket, NBR gasket, or another type. NBR gaskets are not intended for use with gasoline, kerosene, or other petroleum products. If your valve is needed for these, please purchase a valve with a VITON gasket. PRESSURE All solenoid valves need some pressure to actuate. This is especially true of pilot or indirectly operated valves.

Product Features

  • Constructed of industrial grade brass, this valve is corrosion resistant, more conducive for welding, optimal for higher temperature projects, and can be used with gasoline, diesel fuel, kerosene oil, natural gas, air etc. Due to the chemical composition of brass, this valve should NOT be used with projects involving drinking water or other water projects.
  • This valve was manufactured with a VITON seal. VITON is the most durable and high performance rubber material with the ability to resist high temperatures and corrosive chemicals and other fluids like gasoline, diesel fuel, oils, and lubricants.
  • This highly responsive valve will open and close in less than 1 second when actuated; meaning it will open or close the flow instantaneously when energized or de-energized. Also, our U.S. SOLID engineers have determined that the life cycle of this valve is well over a million cycles with proper operating conditions and maintenance.
  • PLEASE NOTE: This valve is NOT a continuous duty valve and should NOT be in continuous use for more than 8 hours in a single cycle; to do so will shorten the life of the valve and may cause the core of the valve to burn out. If you need a continuous duty valve for your project please search for our U.S. SOLID Motorized Ball Valves.
  • As with all U.S. SOLID products, this valve comes with a ONE YEAR WARRANTY. If the valve does become defective within the first year of purchase, U.S. SOLID will gladly replace it.