{"id":7086396702900,"title":"12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A","handle":"12v-110v-dc-miniature-circuit-breaker-6-amp-2-pole-battery-breaker-protector-for-solar-pv-system-and-rv-thermal-magnetic-trip-din-rail-mount-chtaixi-dc-disconnect-switch-b6-6-a","description":"\u003ch3\u003e12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eWarm Tips: Pay attention to polarity. Select wire size\naccording to rated current . DC Miniature Circuit Breaker TXC65Z-60 Curve B 2P\nMagnetic trip range 4-7 times rated current.Suitable for low short-circuit\ncurrent circuits.Low voltage circuits short-circuit protection.Can be used in\n12V 24V 36V 48V low voltage circuits. package includes: 1 x DC miniature\ncircuit breaker (2P) 2 x M5 OT lugs (size according to the rated current) 2 x\nplastic hole plugs Read more Quality Products to Protect Your Electricity\nSafety Silver Alloy Contacts Contacts are very important to circuit breakers,\nespecially for DC distribution with high arc extinguishing requirements. Good\ncontacts can reduce the heat generated by arcing during disconnection and\nreduce the wear of the contacts. This DC MCB uses silver alloy contacts, which\nimproves electrical durability, and protects your electricity safety for a\nlong time. Polarity Marked This DC mini circuit breaker has no polarity\nrequirement in use, and the positive and negative poles can be inverted.\nHowever, the installation, use, and maintenance of DC circuits are based on\npolarity. So, in order to provide reliable indication and reference for the\ndistribution, we highly recommend that you wire according to the marked\npolarity. Indication Green indication: OFF Red indication: ON Read more\nSpecifications product type DC Miniature Circuit Breaker rated operational\nvoltage 12V - 110V DC rated current [In] 6A \/ 10A \/ 15 A \/ 20 A \/ 25 A \/ 32 A\n\/ 40 A \/ 50 A \/ 60 A (optional) poles 2 P trip unit technology Thermal-\nmagnetic curve code B breaking capacity 6 kA Ics=Icu Uimp 4 kV mechanical\ndurability 10000 cycles electrical durability 2000 cycles operating\ntemperature -13°F(-25℃) ~ 140°F(60℃) mounting support 35 mm DIN rail\ntightening torque 2.5 N.m standard IEC60947-2 Lugs Wiring Notice We first\nrecommend that you wire the tunnel terminals with no lug wire. For some cases,\ncan also use lugs wiring.Lug size: M5, a\u0026lt;0.53’’(13.5mm),\nb\u0026lt;0.12’’(3.1mm).Complete the lugs wiring before mounting. Step 1 Tighten the\ntunnel terminal screws. Step 2 Insert the hole plug horizontally (the two\nconvex of the hole plug are on the side, or lug wiring may fail) into the hole\nunder the tunnel terminal (Size is just fit, need to tilt the hole plug a\nlittle down). Step 3 Loosen the tunnel terminal screw and remove it.Put the\nwire lug into the lug terminal, put back the screw, and tighten. Read more DC\nMiniature Circuit Breaker 12V-110V DC Miniature Circuit Breaker 12V-110V DC\nMiniature Circuit Breaker 500V DC Miniature Circuit Breaker 500V DC Miniature\nCircuit Breaker 1000V Amperage 6A \/ 10A \/ 15A \/ 20A \/ 25A \/ 32A \/ 40A \/ 50A\/\n60A 6A \/ 10A \/ 15A \/ 20A \/ 25A \/ 32A \/ 40A \/ 50A\/ 60A 10A\/ 16A\/ 20A\/ 25A\/ 32A\/\n40A\/ 50A\/ 63A 80A \/ 100A \/ 125A 10A\/ 16A\/ 20A\/ 25A\/ 32A\/ 40A\/ 50A\/ 63A Curve\ncode B B C C C Poles 1P 2P 2P 2P 2P Dimensions (inches) 2.96 x 0.71 x 3.26\n2.96 x 1.42 x 3.26 2.95 x 1.42 x 3.15 3 x 2.13 x 3.15 2.95 x 1.42 x 3.15 Main\nuses Battery protection, battery disconnect. Battery protection, battery\ndisconnect. Solar panel disconnect. Solar panel disconnect, main bus control.\nSolar panel disconnect.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eFUNCTIONS: Used to protect 12V 24V 36V 48V 60V 100V DC circuit from overload and short circuit damage, and can also be used for control and isolation.\u003c\/li\u003e\n \u003cli\u003eFAST TRIP: The electromagnetic trip system can trip immediately when short-circuited.\u003c\/li\u003e\n \u003cli\u003eCURVE B: Magnetic trip range 4-7 times rated current.\u003c\/li\u003e\n \u003cli\u003eAPPLICATION: Used in battery power systems, solar photovoltaic systems, RV, electric moped, or other DC systems.\u003c\/li\u003e\n \u003cli\u003eINSTALLATION: Screw clamps wire or M5 wire lug (size fits), 35 mm DIN rail mount.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-03-18T23:18:48+11:00","created_at":"2022-03-18T23:18:48+11:00","vendor":"CHTAIXI","type":"Miniature Circuit Breakers","tags":["auspowers_batchone"],"price":13600,"price_min":13600,"price_max":13600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41334907830452,"title":"6 A \/ 2 Pole","option1":"6 A","option2":"2 Pole","option3":null,"sku":"B09H4VLZPX","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A - 6 A \/ 2 Pole","public_title":"6 A \/ 2 Pole","options":["6 A","2 Pole"],"price":13600,"weight":200,"compare_at_price":null,"inventory_management":null,"barcode":"817218224643","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B09H4VLZPX.jpg?v=1648568088","\/\/auspowers.com\/cdn\/shop\/products\/512AycoaQjL.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/51rBO6nTNgL.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/51PdmsmlWPL.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/51dm0B_AU-L.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/61gp1AXo0tL.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/71ngvWYt7jL.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/51wIbRuIA4L.jpg?v=1647605928"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B09H4VLZPX.jpg?v=1648568088","options":["Size","Style"],"media":[{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25349114921140,"position":1,"preview_image":{"aspect_ratio":0.685,"height":1460,"width":1000,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B09H4VLZPX.jpg?v=1648568088"},"aspect_ratio":0.685,"height":1460,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B09H4VLZPX.jpg?v=1648568088","width":1000},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586498740,"position":2,"preview_image":{"aspect_ratio":0.959,"height":1460,"width":1400,"src":"\/\/auspowers.com\/cdn\/shop\/products\/512AycoaQjL.jpg?v=1647605928"},"aspect_ratio":0.959,"height":1460,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/512AycoaQjL.jpg?v=1647605928","width":1400},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586531508,"position":3,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51rBO6nTNgL.jpg?v=1647605928"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51rBO6nTNgL.jpg?v=1647605928","width":1200},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586564276,"position":4,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51PdmsmlWPL.jpg?v=1647605928"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51PdmsmlWPL.jpg?v=1647605928","width":1200},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586597044,"position":5,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51dm0B_AU-L.jpg?v=1647605928"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51dm0B_AU-L.jpg?v=1647605928","width":1200},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586629812,"position":6,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61gp1AXo0tL.jpg?v=1647605928"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61gp1AXo0tL.jpg?v=1647605928","width":1200},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586662580,"position":7,"preview_image":{"aspect_ratio":0.874,"height":1830,"width":1600,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71ngvWYt7jL.jpg?v=1647605928"},"aspect_ratio":0.874,"height":1830,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71ngvWYt7jL.jpg?v=1647605928","width":1600},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586695348,"position":8,"preview_image":{"aspect_ratio":0.845,"height":1420,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51wIbRuIA4L.jpg?v=1647605928"},"aspect_ratio":0.845,"height":1420,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51wIbRuIA4L.jpg?v=1647605928","width":1200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003e12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eWarm Tips: Pay attention to polarity. Select wire size\naccording to rated current . DC Miniature Circuit Breaker TXC65Z-60 Curve B 2P\nMagnetic trip range 4-7 times rated current.Suitable for low short-circuit\ncurrent circuits.Low voltage circuits short-circuit protection.Can be used in\n12V 24V 36V 48V low voltage circuits. package includes: 1 x DC miniature\ncircuit breaker (2P) 2 x M5 OT lugs (size according to the rated current) 2 x\nplastic hole plugs Read more Quality Products to Protect Your Electricity\nSafety Silver Alloy Contacts Contacts are very important to circuit breakers,\nespecially for DC distribution with high arc extinguishing requirements. Good\ncontacts can reduce the heat generated by arcing during disconnection and\nreduce the wear of the contacts. This DC MCB uses silver alloy contacts, which\nimproves electrical durability, and protects your electricity safety for a\nlong time. Polarity Marked This DC mini circuit breaker has no polarity\nrequirement in use, and the positive and negative poles can be inverted.\nHowever, the installation, use, and maintenance of DC circuits are based on\npolarity. So, in order to provide reliable indication and reference for the\ndistribution, we highly recommend that you wire according to the marked\npolarity. Indication Green indication: OFF Red indication: ON Read more\nSpecifications product type DC Miniature Circuit Breaker rated operational\nvoltage 12V - 110V DC rated current [In] 6A \/ 10A \/ 15 A \/ 20 A \/ 25 A \/ 32 A\n\/ 40 A \/ 50 A \/ 60 A (optional) poles 2 P trip unit technology Thermal-\nmagnetic curve code B breaking capacity 6 kA Ics=Icu Uimp 4 kV mechanical\ndurability 10000 cycles electrical durability 2000 cycles operating\ntemperature -13°F(-25℃) ~ 140°F(60℃) mounting support 35 mm DIN rail\ntightening torque 2.5 N.m standard IEC60947-2 Lugs Wiring Notice We first\nrecommend that you wire the tunnel terminals with no lug wire. For some cases,\ncan also use lugs wiring.Lug size: M5, a\u0026lt;0.53’’(13.5mm),\nb\u0026lt;0.12’’(3.1mm).Complete the lugs wiring before mounting. Step 1 Tighten the\ntunnel terminal screws. Step 2 Insert the hole plug horizontally (the two\nconvex of the hole plug are on the side, or lug wiring may fail) into the hole\nunder the tunnel terminal (Size is just fit, need to tilt the hole plug a\nlittle down). Step 3 Loosen the tunnel terminal screw and remove it.Put the\nwire lug into the lug terminal, put back the screw, and tighten. Read more DC\nMiniature Circuit Breaker 12V-110V DC Miniature Circuit Breaker 12V-110V DC\nMiniature Circuit Breaker 500V DC Miniature Circuit Breaker 500V DC Miniature\nCircuit Breaker 1000V Amperage 6A \/ 10A \/ 15A \/ 20A \/ 25A \/ 32A \/ 40A \/ 50A\/\n60A 6A \/ 10A \/ 15A \/ 20A \/ 25A \/ 32A \/ 40A \/ 50A\/ 60A 10A\/ 16A\/ 20A\/ 25A\/ 32A\/\n40A\/ 50A\/ 63A 80A \/ 100A \/ 125A 10A\/ 16A\/ 20A\/ 25A\/ 32A\/ 40A\/ 50A\/ 63A Curve\ncode B B C C C Poles 1P 2P 2P 2P 2P Dimensions (inches) 2.96 x 0.71 x 3.26\n2.96 x 1.42 x 3.26 2.95 x 1.42 x 3.15 3 x 2.13 x 3.15 2.95 x 1.42 x 3.15 Main\nuses Battery protection, battery disconnect. Battery protection, battery\ndisconnect. Solar panel disconnect. Solar panel disconnect, main bus control.\nSolar panel disconnect.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eFUNCTIONS: Used to protect 12V 24V 36V 48V 60V 100V DC circuit from overload and short circuit damage, and can also be used for control and isolation.\u003c\/li\u003e\n \u003cli\u003eFAST TRIP: The electromagnetic trip system can trip immediately when short-circuited.\u003c\/li\u003e\n \u003cli\u003eCURVE B: Magnetic trip range 4-7 times rated current.\u003c\/li\u003e\n \u003cli\u003eAPPLICATION: Used in battery power systems, solar photovoltaic systems, RV, electric moped, or other DC systems.\u003c\/li\u003e\n \u003cli\u003eINSTALLATION: Screw clamps wire or M5 wire lug (size fits), 35 mm DIN rail mount.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A

In Stock. Leaves warehouse within 2 - 3 business days

$136.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6

Warm Tips: Pay attention to polarity. Select wire size according to rated current . DC Miniature Circuit Breaker TXC65Z-60 Curve B 2P Magnetic trip range 4-7 times rated current.Suitable for low short-circuit current circuits.Low voltage circuits short-circuit protection.Can be used in 12V 24V 36V 48V low voltage circuits. package includes: 1 x DC miniature circuit breaker (2P) 2 x M5 OT lugs (size according to the rated current) 2 x plastic hole plugs Read more Quality Products to Protect Your Electricity Safety Silver Alloy Contacts Contacts are very important to circuit breakers, especially for DC distribution with high arc extinguishing requirements. Good contacts can reduce the heat generated by arcing during disconnection and reduce the wear of the contacts. This DC MCB uses silver alloy contacts, which improves electrical durability, and protects your electricity safety for a long time. Polarity Marked This DC mini circuit breaker has no polarity requirement in use, and the positive and negative poles can be inverted. However, the installation, use, and maintenance of DC circuits are based on polarity. So, in order to provide reliable indication and reference for the distribution, we highly recommend that you wire according to the marked polarity. Indication Green indication: OFF Red indication: ON Read more Specifications product type DC Miniature Circuit Breaker rated operational voltage 12V - 110V DC rated current [In] 6A / 10A / 15 A / 20 A / 25 A / 32 A / 40 A / 50 A / 60 A (optional) poles 2 P trip unit technology Thermal- magnetic curve code B breaking capacity 6 kA Ics=Icu Uimp 4 kV mechanical durability 10000 cycles electrical durability 2000 cycles operating temperature -13°F(-25℃) ~ 140°F(60℃) mounting support 35 mm DIN rail tightening torque 2.5 N.m standard IEC60947-2 Lugs Wiring Notice We first recommend that you wire the tunnel terminals with no lug wire. For some cases, can also use lugs wiring.Lug size: M5, a<0.53’’(13.5mm), b<0.12’’(3.1mm).Complete the lugs wiring before mounting. Step 1 Tighten the tunnel terminal screws. Step 2 Insert the hole plug horizontally (the two convex of the hole plug are on the side, or lug wiring may fail) into the hole under the tunnel terminal (Size is just fit, need to tilt the hole plug a little down). Step 3 Loosen the tunnel terminal screw and remove it.Put the wire lug into the lug terminal, put back the screw, and tighten. Read more DC Miniature Circuit Breaker 12V-110V DC Miniature Circuit Breaker 12V-110V DC Miniature Circuit Breaker 500V DC Miniature Circuit Breaker 500V DC Miniature Circuit Breaker 1000V Amperage 6A / 10A / 15A / 20A / 25A / 32A / 40A / 50A/ 60A 6A / 10A / 15A / 20A / 25A / 32A / 40A / 50A/ 60A 10A/ 16A/ 20A/ 25A/ 32A/ 40A/ 50A/ 63A 80A / 100A / 125A 10A/ 16A/ 20A/ 25A/ 32A/ 40A/ 50A/ 63A Curve code B B C C C Poles 1P 2P 2P 2P 2P Dimensions (inches) 2.96 x 0.71 x 3.26 2.96 x 1.42 x 3.26 2.95 x 1.42 x 3.15 3 x 2.13 x 3.15 2.95 x 1.42 x 3.15 Main uses Battery protection, battery disconnect. Battery protection, battery disconnect. Solar panel disconnect. Solar panel disconnect, main bus control. Solar panel disconnect.

Product Features

  • FUNCTIONS: Used to protect 12V 24V 36V 48V 60V 100V DC circuit from overload and short circuit damage, and can also be used for control and isolation.
  • FAST TRIP: The electromagnetic trip system can trip immediately when short-circuited.
  • CURVE B: Magnetic trip range 4-7 times rated current.
  • APPLICATION: Used in battery power systems, solar photovoltaic systems, RV, electric moped, or other DC systems.
  • INSTALLATION: Screw clamps wire or M5 wire lug (size fits), 35 mm DIN rail mount.

Related Products