{"id":7087172944052,"title":"Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable","handle":"taidacent-automatic-water-level-controller-water-pump-controller-water-tank-automatic-filling-system-either-to-fill-or-empty-a-tank-two-non-contact-water-tank-water-level-sensors-1-meter-cable","description":"\u003ch3\u003eTaidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eBasic function introduction Automatic water level control:\nthe water level is lower than the low level sensor probe, the water pump is\nautomatically started, the water level rises to the high level, and the water\npump is automatically turned off. 4 \/ 14 (Automatic water supply) Automatic\nwater level control: the water level rises to a high level, the water pump is\nautomatically started, and the water level is lower than the low level sensor\nprobe, and the water pump is automatically turned off. (Automatic drainage)\nManual automatic switching: The controller enters the automatic working mode\nby default when it is turned on. Press the K1 key to switch the working mode.\nThe red light is on for automatic mode, and the red light is off for manual\nmode. Water inlet pipe abnormal alarm: When the controller starts to pump\nwater automatically, and the water inlet pipe probe cannot detect water within\na certain period of time (within 10 to 30 seconds), the load output relay is\ndisconnected to stop pumping, and the alarm output relay is closed. Abnormal\nwater overflow alarm: the controller starts to pump water automatically, and\nwhen the water surface rises to the position of the overflow alarm probe, the\nload output relay is disconnected to stop pumping, and the alarm output relay\nis closed. Abnormal low probe alarm: the controller starts to pump water\nautomatically. If the low probe fails or falls off, and the water surface\nrises to the high probe position, the load output relay is disconnected to\nstop pumping, and the alarm output relay is closed. Terminal description Oview\nEasy to insall.high and low level controller and Y25-V liquid level detection\nhead realize the function of liquid level high and low control: when the\ncontainer liquid level is too low, the low liquid level alarm signal sent by\nthe low liquid level sensor is triggered to trigger the C352 controller to\nclose the relay to start the water pump Add the liquid level, when the liquid\nlevel reaches a certain height, the high liquid level sensor sends out a\nsignal to trigger the C352 controller to disconnect the relay and\nautomatically stop the water pump to work in a cycle. Thereby, the function of\nautomatic control of the container liquid level is realized, and the container\nliquid level is kept stable. Product Features AC180V~250V power supply Relay\ndry node output, suitable for various load control The control is diversified,\nand the pump can be controlled in manual or automatic mode The installation is\nsimple and convenient, it can be installed with screws or electric box tracks\nParameter Input voltage: AC180V-250V,50\/60Hz Working current: Working current\n≤110 mA, static current consumption ≤20mA Load power: Resistive load below\n1.6KW (overload or three-phase load needs to be installed with AC contactor)\nInductive load below 1KW (overload or three-phase load needs to be installed\nwith AC contactor) Inductive loads refer to loads with inductive coils, such\nas motors, electromagnets, solenoid valves and so on. Alarm Output: 800W\n(resistive load) normally open \/ normally closed output Output method Normally\nopen\/normally closed output Input signal: Low sensor signal input; High-\nposition sensing signal input; Sensor interface voltage: DC 12V Operating\ntemperature: -10~75℃ Dimensions: 1159040 Installation method description\nhigh and low water level controller (the bottom shell is equipped with 35mm\ntrack groove) can be directly hung in the electric box and electric cabinet.\nSensor probe installation: different types of sensor probes have different\ninstallation methods, please refer to the relevant chapters of the\nspecifications corresponding to the sensor model you are using. I won't repeat\nthem here. 1P wiring diagram 1P wiring diagram The following figure uses the\nhigh and low water level controller C352 + 1 XKC-Y25 non-contact liquid level\nsensor to realize automatic water level control. Correspondence diagram of\nsignal input and relay output Input signal Low bit is 0, high bit is 0; Load\noutput: Normally open end (NO) is closed, normally closed end (NC) is open\nInput signal the low bit is 1, the high bit is 0 (The water level rises); Load\noutput: Normally open end (NO) is closed, normally closed end (NC) is open\nInput signal the low bit is 1, the high bit is 1; Load output: Normally open\n(NO) open, normally closed (NC) closed Input signal the low bit is 1, the high\nbit is 0 (Water level drops); Load output: Normally open (NO) open, normally\nclosed (NC) closed Input signal the low bit is 0, high bit is 0; Load output:\nNormally open end (NO) is closed, normally closed end (NC) is open Input\nsignal the low bit is 1, the high bit is 0 (The water level rises); Load\noutput: Normally open end (NO) is closed, normally closed end (NC) is open\nInput signal Input signal the low bit is 1, the high bit is 1; Load output:\nNormally open (NO) open, normally closed (NC) closed Input signal Input signal\nthe low bit is 1, the high bit is 0 (Water level drops) ; Load output:\nNormally open (NO) open, normally closed (NC) closed Alarm signal status low\nbit is 0, high bit is 1, Alarm Output: Normally open end (NO) is closed,\nnormally closed end (NC) is open Alarm signal status high overflow is 1;\nNormally open end (NO) is closed, normally closed end (NC) is open Alarm\nstatus, load output: normally open open, normally closed closed (Relay\ndisconnected state, load disconnected to enter protection) Note: 0 means that\nthe probe cannot detect water and outputs a low-level 0V voltage, 1 means that\nthe probe detects that there is water and outputs a high-level 12V voltage. 2P\nwiring diagram 2P wiring diagram The following figure uses the high and low\nwater level controller non-contact liquid level sensors to achieve automatic\nwater level control. 3P wiring diagram The following figure uses the high and\nlow water level controller and non-contact liquid level sensors to realize\nfunctions such as automatic water level control and water pump idling\nprotection.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eWhen the liquid level of the container is too low, the low liquid level alarm signal from the low liquid level sensor is triggered to trigger the controller to close the relay to start the water pump to add liquid level. When the liquid level reaches a certain height, the high liquid level sensor sends a signal to trigger the controller to disconnect the relay to automatically stop the water pump. You can use the controller to either to fill or empty a tank\u003c\/li\u003e\n \u003cli\u003eAC95 ~ 265V wide voltage power supply.\u003c\/li\u003e\n \u003cli\u003eRelay dry contact output, can be applied to a variety of load.\u003c\/li\u003e\n \u003cli\u003eControl diversification, can control the pump in manual or automatic mode.\u003c\/li\u003e\n \u003cli\u003eYou can adjust sensitivity: Remove the plastic cover of the sensors and turn the very small screw, clockwise decrease sensitivity, counter clockwise to increase the sensitivity.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-03-19T08:08:33+11:00","created_at":"2022-03-19T08:08:33+11:00","vendor":"Taidacent","type":"Flow Switches","tags":["auspowers_batchone"],"price":26800,"price_min":26800,"price_max":26800,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41336464933044,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"B07RD7Y39P","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable","public_title":null,"options":["Default Title"],"price":26800,"weight":231,"compare_at_price":null,"inventory_management":null,"barcode":"691041000595","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B07RD7Y39P.jpg?v=1648590102","\/\/auspowers.com\/cdn\/shop\/products\/5191D_T60AL.jpg?v=1647637713","\/\/auspowers.com\/cdn\/shop\/products\/8129KosSgRL.jpg?v=1647637713","\/\/auspowers.com\/cdn\/shop\/products\/81tgNP4R-8L.jpg?v=1647637713","\/\/auspowers.com\/cdn\/shop\/products\/51gx2nJv9IL.jpg?v=1647637713","\/\/auspowers.com\/cdn\/shop\/products\/71xTHt8zbHL.jpg?v=1647637713","\/\/auspowers.com\/cdn\/shop\/products\/61StAsfbWFL.jpg?v=1647637713","\/\/auspowers.com\/cdn\/shop\/products\/918FUDKBxRL.jpg?v=1647637713","\/\/auspowers.com\/cdn\/shop\/products\/811lR4N6JGL.jpg?v=1647637713"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B07RD7Y39P.jpg?v=1648590102","options":["Title"],"media":[{"alt":"[Australia - AusPower] - Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable ","id":25352923414708,"position":1,"preview_image":{"aspect_ratio":1.0,"height":1024,"width":1024,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B07RD7Y39P.jpg?v=1648590102"},"aspect_ratio":1.0,"height":1024,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B07RD7Y39P.jpg?v=1648590102","width":1024},{"alt":"[Australia - AusPower] - Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable ","id":25209340690612,"position":2,"preview_image":{"aspect_ratio":1.796,"height":570,"width":1024,"src":"\/\/auspowers.com\/cdn\/shop\/products\/5191D_T60AL.jpg?v=1647637713"},"aspect_ratio":1.796,"height":570,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/5191D_T60AL.jpg?v=1647637713","width":1024},{"alt":"[Australia - AusPower] - Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable ","id":25209340723380,"position":3,"preview_image":{"aspect_ratio":1.0,"height":2560,"width":2560,"src":"\/\/auspowers.com\/cdn\/shop\/products\/8129KosSgRL.jpg?v=1647637713"},"aspect_ratio":1.0,"height":2560,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/8129KosSgRL.jpg?v=1647637713","width":2560},{"alt":"[Australia - AusPower] - Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable ","id":25209340756148,"position":4,"preview_image":{"aspect_ratio":1.0,"height":2560,"width":2560,"src":"\/\/auspowers.com\/cdn\/shop\/products\/81tgNP4R-8L.jpg?v=1647637713"},"aspect_ratio":1.0,"height":2560,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/81tgNP4R-8L.jpg?v=1647637713","width":2560},{"alt":"[Australia - AusPower] - Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable ","id":25209340788916,"position":5,"preview_image":{"aspect_ratio":1.228,"height":834,"width":1024,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51gx2nJv9IL.jpg?v=1647637713"},"aspect_ratio":1.228,"height":834,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51gx2nJv9IL.jpg?v=1647637713","width":1024},{"alt":"[Australia - AusPower] - Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable ","id":25209340821684,"position":6,"preview_image":{"aspect_ratio":0.534,"height":1480,"width":790,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71xTHt8zbHL.jpg?v=1647637713"},"aspect_ratio":0.534,"height":1480,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71xTHt8zbHL.jpg?v=1647637713","width":790},{"alt":"[Australia - AusPower] - Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable ","id":25209340854452,"position":7,"preview_image":{"aspect_ratio":1.298,"height":856,"width":1111,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61StAsfbWFL.jpg?v=1647637713"},"aspect_ratio":1.298,"height":856,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61StAsfbWFL.jpg?v=1647637713","width":1111},{"alt":"[Australia - AusPower] - Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable ","id":25209340887220,"position":8,"preview_image":{"aspect_ratio":1.0,"height":2560,"width":2560,"src":"\/\/auspowers.com\/cdn\/shop\/products\/918FUDKBxRL.jpg?v=1647637713"},"aspect_ratio":1.0,"height":2560,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/918FUDKBxRL.jpg?v=1647637713","width":2560},{"alt":"[Australia - AusPower] - Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable ","id":25209340919988,"position":9,"preview_image":{"aspect_ratio":1.0,"height":2560,"width":2560,"src":"\/\/auspowers.com\/cdn\/shop\/products\/811lR4N6JGL.jpg?v=1647637713"},"aspect_ratio":1.0,"height":2560,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/811lR4N6JGL.jpg?v=1647637713","width":2560}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eTaidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eBasic function introduction Automatic water level control:\nthe water level is lower than the low level sensor probe, the water pump is\nautomatically started, the water level rises to the high level, and the water\npump is automatically turned off. 4 \/ 14 (Automatic water supply) Automatic\nwater level control: the water level rises to a high level, the water pump is\nautomatically started, and the water level is lower than the low level sensor\nprobe, and the water pump is automatically turned off. (Automatic drainage)\nManual automatic switching: The controller enters the automatic working mode\nby default when it is turned on. Press the K1 key to switch the working mode.\nThe red light is on for automatic mode, and the red light is off for manual\nmode. Water inlet pipe abnormal alarm: When the controller starts to pump\nwater automatically, and the water inlet pipe probe cannot detect water within\na certain period of time (within 10 to 30 seconds), the load output relay is\ndisconnected to stop pumping, and the alarm output relay is closed. Abnormal\nwater overflow alarm: the controller starts to pump water automatically, and\nwhen the water surface rises to the position of the overflow alarm probe, the\nload output relay is disconnected to stop pumping, and the alarm output relay\nis closed. Abnormal low probe alarm: the controller starts to pump water\nautomatically. If the low probe fails or falls off, and the water surface\nrises to the high probe position, the load output relay is disconnected to\nstop pumping, and the alarm output relay is closed. Terminal description Oview\nEasy to insall.high and low level controller and Y25-V liquid level detection\nhead realize the function of liquid level high and low control: when the\ncontainer liquid level is too low, the low liquid level alarm signal sent by\nthe low liquid level sensor is triggered to trigger the C352 controller to\nclose the relay to start the water pump Add the liquid level, when the liquid\nlevel reaches a certain height, the high liquid level sensor sends out a\nsignal to trigger the C352 controller to disconnect the relay and\nautomatically stop the water pump to work in a cycle. Thereby, the function of\nautomatic control of the container liquid level is realized, and the container\nliquid level is kept stable. Product Features AC180V~250V power supply Relay\ndry node output, suitable for various load control The control is diversified,\nand the pump can be controlled in manual or automatic mode The installation is\nsimple and convenient, it can be installed with screws or electric box tracks\nParameter Input voltage: AC180V-250V,50\/60Hz Working current: Working current\n≤110 mA, static current consumption ≤20mA Load power: Resistive load below\n1.6KW (overload or three-phase load needs to be installed with AC contactor)\nInductive load below 1KW (overload or three-phase load needs to be installed\nwith AC contactor) Inductive loads refer to loads with inductive coils, such\nas motors, electromagnets, solenoid valves and so on. Alarm Output: 800W\n(resistive load) normally open \/ normally closed output Output method Normally\nopen\/normally closed output Input signal: Low sensor signal input; High-\nposition sensing signal input; Sensor interface voltage: DC 12V Operating\ntemperature: -10~75℃ Dimensions: 1159040 Installation method description\nhigh and low water level controller (the bottom shell is equipped with 35mm\ntrack groove) can be directly hung in the electric box and electric cabinet.\nSensor probe installation: different types of sensor probes have different\ninstallation methods, please refer to the relevant chapters of the\nspecifications corresponding to the sensor model you are using. I won't repeat\nthem here. 1P wiring diagram 1P wiring diagram The following figure uses the\nhigh and low water level controller C352 + 1 XKC-Y25 non-contact liquid level\nsensor to realize automatic water level control. Correspondence diagram of\nsignal input and relay output Input signal Low bit is 0, high bit is 0; Load\noutput: Normally open end (NO) is closed, normally closed end (NC) is open\nInput signal the low bit is 1, the high bit is 0 (The water level rises); Load\noutput: Normally open end (NO) is closed, normally closed end (NC) is open\nInput signal the low bit is 1, the high bit is 1; Load output: Normally open\n(NO) open, normally closed (NC) closed Input signal the low bit is 1, the high\nbit is 0 (Water level drops); Load output: Normally open (NO) open, normally\nclosed (NC) closed Input signal the low bit is 0, high bit is 0; Load output:\nNormally open end (NO) is closed, normally closed end (NC) is open Input\nsignal the low bit is 1, the high bit is 0 (The water level rises); Load\noutput: Normally open end (NO) is closed, normally closed end (NC) is open\nInput signal Input signal the low bit is 1, the high bit is 1; Load output:\nNormally open (NO) open, normally closed (NC) closed Input signal Input signal\nthe low bit is 1, the high bit is 0 (Water level drops) ; Load output:\nNormally open (NO) open, normally closed (NC) closed Alarm signal status low\nbit is 0, high bit is 1, Alarm Output: Normally open end (NO) is closed,\nnormally closed end (NC) is open Alarm signal status high overflow is 1;\nNormally open end (NO) is closed, normally closed end (NC) is open Alarm\nstatus, load output: normally open open, normally closed closed (Relay\ndisconnected state, load disconnected to enter protection) Note: 0 means that\nthe probe cannot detect water and outputs a low-level 0V voltage, 1 means that\nthe probe detects that there is water and outputs a high-level 12V voltage. 2P\nwiring diagram 2P wiring diagram The following figure uses the high and low\nwater level controller non-contact liquid level sensors to achieve automatic\nwater level control. 3P wiring diagram The following figure uses the high and\nlow water level controller and non-contact liquid level sensors to realize\nfunctions such as automatic water level control and water pump idling\nprotection.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eWhen the liquid level of the container is too low, the low liquid level alarm signal from the low liquid level sensor is triggered to trigger the controller to close the relay to start the water pump to add liquid level. When the liquid level reaches a certain height, the high liquid level sensor sends a signal to trigger the controller to disconnect the relay to automatically stop the water pump. You can use the controller to either to fill or empty a tank\u003c\/li\u003e\n \u003cli\u003eAC95 ~ 265V wide voltage power supply.\u003c\/li\u003e\n \u003cli\u003eRelay dry contact output, can be applied to a variety of load.\u003c\/li\u003e\n \u003cli\u003eControl diversification, can control the pump in manual or automatic mode.\u003c\/li\u003e\n \u003cli\u003eYou can adjust sensitivity: Remove the plastic cover of the sensors and turn the very small screw, clockwise decrease sensitivity, counter clockwise to increase the sensitivity.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}

Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable

In Stock. Leaves warehouse within 2 - 3 business days

$268.00 AUD
Maximum quantity available reached.
Free Shipping Australia Wide
100% Safe & Secure Checkout
100 Days Return Policy *
1 Year Warranty *

Taidacent Automatic Water Level Controller Water Pump Controller Water Tank Automatic Filling System Either to Fill or Empty a Tank Two Non Contact Water Tank Water Level Sensors 1 Meter Cable

Basic function introduction Automatic water level control: the water level is lower than the low level sensor probe, the water pump is automatically started, the water level rises to the high level, and the water pump is automatically turned off. 4 / 14 (Automatic water supply) Automatic water level control: the water level rises to a high level, the water pump is automatically started, and the water level is lower than the low level sensor probe, and the water pump is automatically turned off. (Automatic drainage) Manual automatic switching: The controller enters the automatic working mode by default when it is turned on. Press the K1 key to switch the working mode. The red light is on for automatic mode, and the red light is off for manual mode. Water inlet pipe abnormal alarm: When the controller starts to pump water automatically, and the water inlet pipe probe cannot detect water within a certain period of time (within 10 to 30 seconds), the load output relay is disconnected to stop pumping, and the alarm output relay is closed. Abnormal water overflow alarm: the controller starts to pump water automatically, and when the water surface rises to the position of the overflow alarm probe, the load output relay is disconnected to stop pumping, and the alarm output relay is closed. Abnormal low probe alarm: the controller starts to pump water automatically. If the low probe fails or falls off, and the water surface rises to the high probe position, the load output relay is disconnected to stop pumping, and the alarm output relay is closed. Terminal description Oview Easy to insall.high and low level controller and Y25-V liquid level detection head realize the function of liquid level high and low control: when the container liquid level is too low, the low liquid level alarm signal sent by the low liquid level sensor is triggered to trigger the C352 controller to close the relay to start the water pump Add the liquid level, when the liquid level reaches a certain height, the high liquid level sensor sends out a signal to trigger the C352 controller to disconnect the relay and automatically stop the water pump to work in a cycle. Thereby, the function of automatic control of the container liquid level is realized, and the container liquid level is kept stable. Product Features AC180V~250V power supply Relay dry node output, suitable for various load control The control is diversified, and the pump can be controlled in manual or automatic mode The installation is simple and convenient, it can be installed with screws or electric box tracks Parameter Input voltage: AC180V-250V,50/60Hz Working current: Working current ≤110 mA, static current consumption ≤20mA Load power: Resistive load below 1.6KW (overload or three-phase load needs to be installed with AC contactor) Inductive load below 1KW (overload or three-phase load needs to be installed with AC contactor) Inductive loads refer to loads with inductive coils, such as motors, electromagnets, solenoid valves and so on. Alarm Output: 800W (resistive load) normally open / normally closed output Output method Normally open/normally closed output Input signal: Low sensor signal input; High- position sensing signal input; Sensor interface voltage: DC 12V Operating temperature: -10~75℃ Dimensions: 1159040 Installation method description high and low water level controller (the bottom shell is equipped with 35mm track groove) can be directly hung in the electric box and electric cabinet. Sensor probe installation: different types of sensor probes have different installation methods, please refer to the relevant chapters of the specifications corresponding to the sensor model you are using. I won't repeat them here. 1P wiring diagram 1P wiring diagram The following figure uses the high and low water level controller C352 + 1 XKC-Y25 non-contact liquid level sensor to realize automatic water level control. Correspondence diagram of signal input and relay output Input signal Low bit is 0, high bit is 0; Load output: Normally open end (NO) is closed, normally closed end (NC) is open Input signal the low bit is 1, the high bit is 0 (The water level rises); Load output: Normally open end (NO) is closed, normally closed end (NC) is open Input signal the low bit is 1, the high bit is 1; Load output: Normally open (NO) open, normally closed (NC) closed Input signal the low bit is 1, the high bit is 0 (Water level drops); Load output: Normally open (NO) open, normally closed (NC) closed Input signal the low bit is 0, high bit is 0; Load output: Normally open end (NO) is closed, normally closed end (NC) is open Input signal the low bit is 1, the high bit is 0 (The water level rises); Load output: Normally open end (NO) is closed, normally closed end (NC) is open Input signal Input signal the low bit is 1, the high bit is 1; Load output: Normally open (NO) open, normally closed (NC) closed Input signal Input signal the low bit is 1, the high bit is 0 (Water level drops) ; Load output: Normally open (NO) open, normally closed (NC) closed Alarm signal status low bit is 0, high bit is 1, Alarm Output: Normally open end (NO) is closed, normally closed end (NC) is open Alarm signal status high overflow is 1; Normally open end (NO) is closed, normally closed end (NC) is open Alarm status, load output: normally open open, normally closed closed (Relay disconnected state, load disconnected to enter protection) Note: 0 means that the probe cannot detect water and outputs a low-level 0V voltage, 1 means that the probe detects that there is water and outputs a high-level 12V voltage. 2P wiring diagram 2P wiring diagram The following figure uses the high and low water level controller non-contact liquid level sensors to achieve automatic water level control. 3P wiring diagram The following figure uses the high and low water level controller and non-contact liquid level sensors to realize functions such as automatic water level control and water pump idling protection.

Product Features

  • When the liquid level of the container is too low, the low liquid level alarm signal from the low liquid level sensor is triggered to trigger the controller to close the relay to start the water pump to add liquid level. When the liquid level reaches a certain height, the high liquid level sensor sends a signal to trigger the controller to disconnect the relay to automatically stop the water pump. You can use the controller to either to fill or empty a tank
  • AC95 ~ 265V wide voltage power supply.
  • Relay dry contact output, can be applied to a variety of load.
  • Control diversification, can control the pump in manual or automatic mode.
  • You can adjust sensitivity: Remove the plastic cover of the sensors and turn the very small screw, clockwise decrease sensitivity, counter clockwise to increase the sensitivity.