CHTAIXI

Sort by:
{"id":7086396702900,"title":"12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A","handle":"12v-110v-dc-miniature-circuit-breaker-6-amp-2-pole-battery-breaker-protector-for-solar-pv-system-and-rv-thermal-magnetic-trip-din-rail-mount-chtaixi-dc-disconnect-switch-b6-6-a","description":"\u003ch3\u003e12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eWarm Tips: Pay attention to polarity. Select wire size\naccording to rated current . DC Miniature Circuit Breaker TXC65Z-60 Curve B 2P\nMagnetic trip range 4-7 times rated current.Suitable for low short-circuit\ncurrent circuits.Low voltage circuits short-circuit protection.Can be used in\n12V 24V 36V 48V low voltage circuits. package includes: 1 x DC miniature\ncircuit breaker (2P) 2 x M5 OT lugs (size according to the rated current) 2 x\nplastic hole plugs Read more Quality Products to Protect Your Electricity\nSafety Silver Alloy Contacts Contacts are very important to circuit breakers,\nespecially for DC distribution with high arc extinguishing requirements. Good\ncontacts can reduce the heat generated by arcing during disconnection and\nreduce the wear of the contacts. This DC MCB uses silver alloy contacts, which\nimproves electrical durability, and protects your electricity safety for a\nlong time. Polarity Marked This DC mini circuit breaker has no polarity\nrequirement in use, and the positive and negative poles can be inverted.\nHowever, the installation, use, and maintenance of DC circuits are based on\npolarity. So, in order to provide reliable indication and reference for the\ndistribution, we highly recommend that you wire according to the marked\npolarity. Indication Green indication: OFF Red indication: ON Read more\nSpecifications product type DC Miniature Circuit Breaker rated operational\nvoltage 12V - 110V DC rated current [In] 6A \/ 10A \/ 15 A \/ 20 A \/ 25 A \/ 32 A\n\/ 40 A \/ 50 A \/ 60 A (optional) poles 2 P trip unit technology Thermal-\nmagnetic curve code B breaking capacity 6 kA Ics=Icu Uimp 4 kV mechanical\ndurability 10000 cycles electrical durability 2000 cycles operating\ntemperature -13°F(-25℃) ~ 140°F(60℃) mounting support 35 mm DIN rail\ntightening torque 2.5 N.m standard IEC60947-2 Lugs Wiring Notice We first\nrecommend that you wire the tunnel terminals with no lug wire. For some cases,\ncan also use lugs wiring.Lug size: M5, a\u0026lt;0.53’’(13.5mm),\nb\u0026lt;0.12’’(3.1mm).Complete the lugs wiring before mounting. Step 1 Tighten the\ntunnel terminal screws. Step 2 Insert the hole plug horizontally (the two\nconvex of the hole plug are on the side, or lug wiring may fail) into the hole\nunder the tunnel terminal (Size is just fit, need to tilt the hole plug a\nlittle down). Step 3 Loosen the tunnel terminal screw and remove it.Put the\nwire lug into the lug terminal, put back the screw, and tighten. Read more DC\nMiniature Circuit Breaker 12V-110V DC Miniature Circuit Breaker 12V-110V DC\nMiniature Circuit Breaker 500V DC Miniature Circuit Breaker 500V DC Miniature\nCircuit Breaker 1000V Amperage 6A \/ 10A \/ 15A \/ 20A \/ 25A \/ 32A \/ 40A \/ 50A\/\n60A 6A \/ 10A \/ 15A \/ 20A \/ 25A \/ 32A \/ 40A \/ 50A\/ 60A 10A\/ 16A\/ 20A\/ 25A\/ 32A\/\n40A\/ 50A\/ 63A 80A \/ 100A \/ 125A 10A\/ 16A\/ 20A\/ 25A\/ 32A\/ 40A\/ 50A\/ 63A Curve\ncode B B C C C Poles 1P 2P 2P 2P 2P Dimensions (inches) 2.96 x 0.71 x 3.26\n2.96 x 1.42 x 3.26 2.95 x 1.42 x 3.15 3 x 2.13 x 3.15 2.95 x 1.42 x 3.15 Main\nuses Battery protection, battery disconnect. Battery protection, battery\ndisconnect. Solar panel disconnect. Solar panel disconnect, main bus control.\nSolar panel disconnect.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eFUNCTIONS: Used to protect 12V 24V 36V 48V 60V 100V DC circuit from overload and short circuit damage, and can also be used for control and isolation.\u003c\/li\u003e\n \u003cli\u003eFAST TRIP: The electromagnetic trip system can trip immediately when short-circuited.\u003c\/li\u003e\n \u003cli\u003eCURVE B: Magnetic trip range 4-7 times rated current.\u003c\/li\u003e\n \u003cli\u003eAPPLICATION: Used in battery power systems, solar photovoltaic systems, RV, electric moped, or other DC systems.\u003c\/li\u003e\n \u003cli\u003eINSTALLATION: Screw clamps wire or M5 wire lug (size fits), 35 mm DIN rail mount.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-03-18T23:18:48+11:00","created_at":"2022-03-18T23:18:48+11:00","vendor":"CHTAIXI","type":"Miniature Circuit Breakers","tags":["auspowers_batchone"],"price":13600,"price_min":13600,"price_max":13600,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41334907830452,"title":"6 A \/ 2 Pole","option1":"6 A","option2":"2 Pole","option3":null,"sku":"B09H4VLZPX","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A - 6 A \/ 2 Pole","public_title":"6 A \/ 2 Pole","options":["6 A","2 Pole"],"price":13600,"weight":200,"compare_at_price":null,"inventory_management":null,"barcode":"817218224643","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B09H4VLZPX.jpg?v=1648568088","\/\/auspowers.com\/cdn\/shop\/products\/512AycoaQjL.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/51rBO6nTNgL.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/51PdmsmlWPL.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/51dm0B_AU-L.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/61gp1AXo0tL.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/71ngvWYt7jL.jpg?v=1647605928","\/\/auspowers.com\/cdn\/shop\/products\/51wIbRuIA4L.jpg?v=1647605928"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B09H4VLZPX.jpg?v=1648568088","options":["Size","Style"],"media":[{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25349114921140,"position":1,"preview_image":{"aspect_ratio":0.685,"height":1460,"width":1000,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B09H4VLZPX.jpg?v=1648568088"},"aspect_ratio":0.685,"height":1460,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B09H4VLZPX.jpg?v=1648568088","width":1000},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586498740,"position":2,"preview_image":{"aspect_ratio":0.959,"height":1460,"width":1400,"src":"\/\/auspowers.com\/cdn\/shop\/products\/512AycoaQjL.jpg?v=1647605928"},"aspect_ratio":0.959,"height":1460,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/512AycoaQjL.jpg?v=1647605928","width":1400},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586531508,"position":3,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51rBO6nTNgL.jpg?v=1647605928"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51rBO6nTNgL.jpg?v=1647605928","width":1200},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586564276,"position":4,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51PdmsmlWPL.jpg?v=1647605928"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51PdmsmlWPL.jpg?v=1647605928","width":1200},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586597044,"position":5,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51dm0B_AU-L.jpg?v=1647605928"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51dm0B_AU-L.jpg?v=1647605928","width":1200},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586629812,"position":6,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61gp1AXo0tL.jpg?v=1647605928"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61gp1AXo0tL.jpg?v=1647605928","width":1200},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586662580,"position":7,"preview_image":{"aspect_ratio":0.874,"height":1830,"width":1600,"src":"\/\/auspowers.com\/cdn\/shop\/products\/71ngvWYt7jL.jpg?v=1647605928"},"aspect_ratio":0.874,"height":1830,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/71ngvWYt7jL.jpg?v=1647605928","width":1600},{"alt":"[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A ","id":25203586695348,"position":8,"preview_image":{"aspect_ratio":0.845,"height":1420,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51wIbRuIA4L.jpg?v=1647605928"},"aspect_ratio":0.845,"height":1420,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51wIbRuIA4L.jpg?v=1647605928","width":1200}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003e12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eWarm Tips: Pay attention to polarity. Select wire size\naccording to rated current . DC Miniature Circuit Breaker TXC65Z-60 Curve B 2P\nMagnetic trip range 4-7 times rated current.Suitable for low short-circuit\ncurrent circuits.Low voltage circuits short-circuit protection.Can be used in\n12V 24V 36V 48V low voltage circuits. package includes: 1 x DC miniature\ncircuit breaker (2P) 2 x M5 OT lugs (size according to the rated current) 2 x\nplastic hole plugs Read more Quality Products to Protect Your Electricity\nSafety Silver Alloy Contacts Contacts are very important to circuit breakers,\nespecially for DC distribution with high arc extinguishing requirements. Good\ncontacts can reduce the heat generated by arcing during disconnection and\nreduce the wear of the contacts. This DC MCB uses silver alloy contacts, which\nimproves electrical durability, and protects your electricity safety for a\nlong time. Polarity Marked This DC mini circuit breaker has no polarity\nrequirement in use, and the positive and negative poles can be inverted.\nHowever, the installation, use, and maintenance of DC circuits are based on\npolarity. So, in order to provide reliable indication and reference for the\ndistribution, we highly recommend that you wire according to the marked\npolarity. Indication Green indication: OFF Red indication: ON Read more\nSpecifications product type DC Miniature Circuit Breaker rated operational\nvoltage 12V - 110V DC rated current [In] 6A \/ 10A \/ 15 A \/ 20 A \/ 25 A \/ 32 A\n\/ 40 A \/ 50 A \/ 60 A (optional) poles 2 P trip unit technology Thermal-\nmagnetic curve code B breaking capacity 6 kA Ics=Icu Uimp 4 kV mechanical\ndurability 10000 cycles electrical durability 2000 cycles operating\ntemperature -13°F(-25℃) ~ 140°F(60℃) mounting support 35 mm DIN rail\ntightening torque 2.5 N.m standard IEC60947-2 Lugs Wiring Notice We first\nrecommend that you wire the tunnel terminals with no lug wire. For some cases,\ncan also use lugs wiring.Lug size: M5, a\u0026lt;0.53’’(13.5mm),\nb\u0026lt;0.12’’(3.1mm).Complete the lugs wiring before mounting. Step 1 Tighten the\ntunnel terminal screws. Step 2 Insert the hole plug horizontally (the two\nconvex of the hole plug are on the side, or lug wiring may fail) into the hole\nunder the tunnel terminal (Size is just fit, need to tilt the hole plug a\nlittle down). Step 3 Loosen the tunnel terminal screw and remove it.Put the\nwire lug into the lug terminal, put back the screw, and tighten. Read more DC\nMiniature Circuit Breaker 12V-110V DC Miniature Circuit Breaker 12V-110V DC\nMiniature Circuit Breaker 500V DC Miniature Circuit Breaker 500V DC Miniature\nCircuit Breaker 1000V Amperage 6A \/ 10A \/ 15A \/ 20A \/ 25A \/ 32A \/ 40A \/ 50A\/\n60A 6A \/ 10A \/ 15A \/ 20A \/ 25A \/ 32A \/ 40A \/ 50A\/ 60A 10A\/ 16A\/ 20A\/ 25A\/ 32A\/\n40A\/ 50A\/ 63A 80A \/ 100A \/ 125A 10A\/ 16A\/ 20A\/ 25A\/ 32A\/ 40A\/ 50A\/ 63A Curve\ncode B B C C C Poles 1P 2P 2P 2P 2P Dimensions (inches) 2.96 x 0.71 x 3.26\n2.96 x 1.42 x 3.26 2.95 x 1.42 x 3.15 3 x 2.13 x 3.15 2.95 x 1.42 x 3.15 Main\nuses Battery protection, battery disconnect. Battery protection, battery\ndisconnect. Solar panel disconnect. Solar panel disconnect, main bus control.\nSolar panel disconnect.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eFUNCTIONS: Used to protect 12V 24V 36V 48V 60V 100V DC circuit from overload and short circuit damage, and can also be used for control and isolation.\u003c\/li\u003e\n \u003cli\u003eFAST TRIP: The electromagnetic trip system can trip immediately when short-circuited.\u003c\/li\u003e\n \u003cli\u003eCURVE B: Magnetic trip range 4-7 times rated current.\u003c\/li\u003e\n \u003cli\u003eAPPLICATION: Used in battery power systems, solar photovoltaic systems, RV, electric moped, or other DC systems.\u003c\/li\u003e\n \u003cli\u003eINSTALLATION: Screw clamps wire or M5 wire lug (size fits), 35 mm DIN rail mount.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}
[Australia - AusPower] - 12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A

12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 6 A

$136.00 AUD

12V-110V DC Miniature Circuit Breaker, 6 Amp 2 Pole Battery Breaker Protector for Solar PV System and RV, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch B6 Warm Tips: Pay attention to polarity. Select wire size according to rated current . DC Miniature Circuit Breaker TXC65Z-60 Curve B 2P Magnetic trip range 4-7 times rated ...


More Info
{"id":7087091482804,"title":"DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 10A","handle":"dc-miniature-circuit-breaker-2-pole-1000v-10-amp-isolator-for-solar-pv-system-thermal-magnetic-trip-din-rail-mount-chtaixi-dc-disconnect-switch-c10-10a","description":"\u003ch3\u003eDC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eChtaixi DC Miniature Circuit Breaker Warm Tips: Pay\nattention to polarity.Select wire size according to rated current. Magnetic\nArc Extinguishing AC has a zero-crossing point, but DC does not, so DC arc is\nmore difficult to extinguish than AC arc, which is why AC circuit breakers can\nnot be used for DC power, and DC circuit breakers can be used for AC power.\nThis DC mini circuit breaker is equipped with a magnetic field system under\nthe breaking contacts, which can pull the arc to the arc extinguishing chamber\nto assist arc extinguishing. Read more Quality Products to Protect Your\nElectricity Safety Polarity Marked This DC MCB has no polarity requirement in\nuse, and the positive and negative poles can be inverted. However, the\ninstallation, use, and maintenance of DC circuits are based on polarity\nrequirements. So, in order to provide reliable indication and reference for\nthe distribution, we highly recommend that you connect the wires according to\nthe marked polarity. Tunnel Terminal The clamping design of the terminal block\nis designed to connect firmly, and the tightening torque is 2.5 N.m. ( Soft\nsilicone wire needs to crimp fixed the wire end with copper crimp before\nwiring. ) Make sure that the wires are tightly connected when connecting to\nprevent loosening and heating. The surface of the terminal is tin-plated, and\nthe plating layer can improve conductivity, corrosion resistance, and\ndurability. Silver Alloy Contacts Contacts are very important to circuit\nbreakers, especially for DC distribution with high arc extinguishing\nrequirements. Good contacts can reduce the heat generated by arcing during\ndisconnection and reduce the wear of the contacts. This DC circuit breaker\nuses silver alloy contacts, which improves electrical durability, and protects\nyour electricity safety for a long time. Read more Specifications product type\nDC Miniature Circuit Breaker rated operational voltage 500 V \/ 1000 V\n(optional) DC rated current [In] 10 A \/ 16 A \/ 20 A \/ 25 A \/ 32 A \/ 40 A \/ 50\nA \/ 63 A (optional) poles 2 P trip unit technology Thermal-magnetic curve code\nC breaking capacity 4 kA Ics=Icu Uimp 4 kV mechanical durability 10000 cycles\nelectrical durability 2000 cycles operating temperature -13°F(-25℃) ~\n140°F(60℃) mounting support 35 mm DIN rail tightening torque 2.5 N.m standard\nIEC60947-2 package includes 1 x DC miniature circuit breaker, 1 x DIN rail, 2\nx screws Installation DIN Rail Install the 35mm DIN rail horizontally in a\nstable environment. Installation Hang the circuit breaker slot on the DIN\nrailPush the lower end of the circuit breaker into the DIN rail Dismounting\nPush the circuit breaker upwardTurn the upper end of the circuit breaker out\nof the DIN rail Read more DC Miniature Circuit Breaker 12V-110V DC Miniature\nCircuit Breaker 12V-110V DC Miniature Circuit Breaker 500V DC Miniature\nCircuit Breaker 500V DC Miniature Circuit Breaker 1000V Amperage 6A \/ 10A \/\n15A \/ 20A \/ 25A \/ 32A \/ 40A \/ 50A\/ 60A 6A \/ 10A \/ 15A \/ 20A \/ 25A \/ 32A \/ 40A\n\/ 50A\/ 60A 10A\/ 16A\/ 20A\/ 25A\/ 32A\/ 40A\/ 50A\/ 63A 80A \/ 100A \/ 125A 10A\/ 16A\/\n20A\/ 25A\/ 32A\/ 40A\/ 50A\/ 63A Curve code B B C C C Poles 1P 2P 2P 2P 2P\nDimensions (inches) 2.96 x 0.71 x 3.26 2.96 x 1.42 x 3.26 2.95 x 1.42 x 3.15 3\nx 2.13 x 3.15 2.95 x 1.42 x 3.15 Main uses Battery protection, battery\ndisconnect. Battery protection, battery disconnect. Solar panel disconnect.\nSolar panel disconnect, main bus control. Solar panel disconnect.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eFUNCTIONS: Used to protect power distribution facilities from overload and short-circuit damage, and can also be used for control and isolation.\u003c\/li\u003e\n \u003cli\u003eFAST TRIP: The electromagnetic trip system can trip immediately when the circuit is short-circuited to protect the safety of the circuit.\u003c\/li\u003e\n \u003cli\u003eARC EXTINGUISHING: DC arc extinguishing is more difficult than AC. This DC mini circuit breaker has a magnetic system to assist arc extinguishing.\u003c\/li\u003e\n \u003cli\u003eAPPLICATION: Used in DC power system, ship electric power system, solar photovoltaic system, or other DC system.\u003c\/li\u003e\n \u003cli\u003eINSTALLATION: Screw clamp wires, 35mm DIN rail mount.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n","published_at":"2022-03-19T07:28:32+11:00","created_at":"2022-03-19T07:28:32+11:00","vendor":"CHTAIXI","type":"Miniature Circuit Breakers","tags":["auspowers_batchone"],"price":13700,"price_min":13700,"price_max":13700,"available":true,"price_varies":false,"compare_at_price":null,"compare_at_price_min":0,"compare_at_price_max":0,"compare_at_price_varies":false,"variants":[{"id":41336372101300,"title":"10A","option1":"10A","option2":null,"option3":null,"sku":"B09BQQCV3P","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 10A - 10A","public_title":"10A","options":["10A"],"price":13700,"weight":191,"compare_at_price":null,"inventory_management":null,"barcode":"015081020366","requires_selling_plan":false,"selling_plan_allocations":[]}],"images":["\/\/auspowers.com\/cdn\/shop\/products\/B09BQQCV3P.jpg?v=1648588724","\/\/auspowers.com\/cdn\/shop\/products\/51vBlz4lZoS.jpg?v=1647635312","\/\/auspowers.com\/cdn\/shop\/products\/51zBGfVQa3L.jpg?v=1647635312","\/\/auspowers.com\/cdn\/shop\/products\/61zQgfY_B4L.jpg?v=1647635312","\/\/auspowers.com\/cdn\/shop\/products\/51Pv26iRsZL.jpg?v=1647635312","\/\/auspowers.com\/cdn\/shop\/products\/61mlM3d4gIL.jpg?v=1647635312","\/\/auspowers.com\/cdn\/shop\/products\/618bZnIG8kL.jpg?v=1647635312"],"featured_image":"\/\/auspowers.com\/cdn\/shop\/products\/B09BQQCV3P.jpg?v=1648588724","options":["Size"],"media":[{"alt":"[Australia - AusPower] - DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 10A ","id":25352739127476,"position":1,"preview_image":{"aspect_ratio":0.96,"height":1250,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/B09BQQCV3P.jpg?v=1648588724"},"aspect_ratio":0.96,"height":1250,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/B09BQQCV3P.jpg?v=1648588724","width":1200},{"alt":"[Australia - AusPower] - DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 10A ","id":25208850514100,"position":2,"preview_image":{"aspect_ratio":1.0,"height":1300,"width":1300,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51vBlz4lZoS.jpg?v=1647635312"},"aspect_ratio":1.0,"height":1300,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51vBlz4lZoS.jpg?v=1647635312","width":1300},{"alt":"[Australia - AusPower] - DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 10A ","id":25208850546868,"position":3,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51zBGfVQa3L.jpg?v=1647635312"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51zBGfVQa3L.jpg?v=1647635312","width":1200},{"alt":"[Australia - AusPower] - DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 10A ","id":25208850579636,"position":4,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61zQgfY_B4L.jpg?v=1647635312"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61zQgfY_B4L.jpg?v=1647635312","width":1200},{"alt":"[Australia - AusPower] - DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 10A ","id":25208850612404,"position":5,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/51Pv26iRsZL.jpg?v=1647635312"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/51Pv26iRsZL.jpg?v=1647635312","width":1200},{"alt":"[Australia - AusPower] - DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 10A ","id":25208850645172,"position":6,"preview_image":{"aspect_ratio":0.8,"height":1500,"width":1200,"src":"\/\/auspowers.com\/cdn\/shop\/products\/61mlM3d4gIL.jpg?v=1647635312"},"aspect_ratio":0.8,"height":1500,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/61mlM3d4gIL.jpg?v=1647635312","width":1200},{"alt":"[Australia - AusPower] - DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 10A ","id":25208850677940,"position":7,"preview_image":{"aspect_ratio":1.0,"height":1400,"width":1400,"src":"\/\/auspowers.com\/cdn\/shop\/products\/618bZnIG8kL.jpg?v=1647635312"},"aspect_ratio":1.0,"height":1400,"media_type":"image","src":"\/\/auspowers.com\/cdn\/shop\/products\/618bZnIG8kL.jpg?v=1647635312","width":1400}],"requires_selling_plan":false,"selling_plan_groups":[],"content":"\u003ch3\u003eDC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10\u003c\/h3\u003e\n\u003cp id=\"b\"\u003eChtaixi DC Miniature Circuit Breaker Warm Tips: Pay\nattention to polarity.Select wire size according to rated current. Magnetic\nArc Extinguishing AC has a zero-crossing point, but DC does not, so DC arc is\nmore difficult to extinguish than AC arc, which is why AC circuit breakers can\nnot be used for DC power, and DC circuit breakers can be used for AC power.\nThis DC mini circuit breaker is equipped with a magnetic field system under\nthe breaking contacts, which can pull the arc to the arc extinguishing chamber\nto assist arc extinguishing. Read more Quality Products to Protect Your\nElectricity Safety Polarity Marked This DC MCB has no polarity requirement in\nuse, and the positive and negative poles can be inverted. However, the\ninstallation, use, and maintenance of DC circuits are based on polarity\nrequirements. So, in order to provide reliable indication and reference for\nthe distribution, we highly recommend that you connect the wires according to\nthe marked polarity. Tunnel Terminal The clamping design of the terminal block\nis designed to connect firmly, and the tightening torque is 2.5 N.m. ( Soft\nsilicone wire needs to crimp fixed the wire end with copper crimp before\nwiring. ) Make sure that the wires are tightly connected when connecting to\nprevent loosening and heating. The surface of the terminal is tin-plated, and\nthe plating layer can improve conductivity, corrosion resistance, and\ndurability. Silver Alloy Contacts Contacts are very important to circuit\nbreakers, especially for DC distribution with high arc extinguishing\nrequirements. Good contacts can reduce the heat generated by arcing during\ndisconnection and reduce the wear of the contacts. This DC circuit breaker\nuses silver alloy contacts, which improves electrical durability, and protects\nyour electricity safety for a long time. Read more Specifications product type\nDC Miniature Circuit Breaker rated operational voltage 500 V \/ 1000 V\n(optional) DC rated current [In] 10 A \/ 16 A \/ 20 A \/ 25 A \/ 32 A \/ 40 A \/ 50\nA \/ 63 A (optional) poles 2 P trip unit technology Thermal-magnetic curve code\nC breaking capacity 4 kA Ics=Icu Uimp 4 kV mechanical durability 10000 cycles\nelectrical durability 2000 cycles operating temperature -13°F(-25℃) ~\n140°F(60℃) mounting support 35 mm DIN rail tightening torque 2.5 N.m standard\nIEC60947-2 package includes 1 x DC miniature circuit breaker, 1 x DIN rail, 2\nx screws Installation DIN Rail Install the 35mm DIN rail horizontally in a\nstable environment. Installation Hang the circuit breaker slot on the DIN\nrailPush the lower end of the circuit breaker into the DIN rail Dismounting\nPush the circuit breaker upwardTurn the upper end of the circuit breaker out\nof the DIN rail Read more DC Miniature Circuit Breaker 12V-110V DC Miniature\nCircuit Breaker 12V-110V DC Miniature Circuit Breaker 500V DC Miniature\nCircuit Breaker 500V DC Miniature Circuit Breaker 1000V Amperage 6A \/ 10A \/\n15A \/ 20A \/ 25A \/ 32A \/ 40A \/ 50A\/ 60A 6A \/ 10A \/ 15A \/ 20A \/ 25A \/ 32A \/ 40A\n\/ 50A\/ 60A 10A\/ 16A\/ 20A\/ 25A\/ 32A\/ 40A\/ 50A\/ 63A 80A \/ 100A \/ 125A 10A\/ 16A\/\n20A\/ 25A\/ 32A\/ 40A\/ 50A\/ 63A Curve code B B C C C Poles 1P 2P 2P 2P 2P\nDimensions (inches) 2.96 x 0.71 x 3.26 2.96 x 1.42 x 3.26 2.95 x 1.42 x 3.15 3\nx 2.13 x 3.15 2.95 x 1.42 x 3.15 Main uses Battery protection, battery\ndisconnect. Battery protection, battery disconnect. Solar panel disconnect.\nSolar panel disconnect, main bus control. Solar panel disconnect.\u003c\/p\u003e \n\n\u003ch3\u003eProduct Features\u003c\/h3\u003e\n \u003cul class=\"a\"\u003e\n \u003cli\u003eFUNCTIONS: Used to protect power distribution facilities from overload and short-circuit damage, and can also be used for control and isolation.\u003c\/li\u003e\n \u003cli\u003eFAST TRIP: The electromagnetic trip system can trip immediately when the circuit is short-circuited to protect the safety of the circuit.\u003c\/li\u003e\n \u003cli\u003eARC EXTINGUISHING: DC arc extinguishing is more difficult than AC. This DC mini circuit breaker has a magnetic system to assist arc extinguishing.\u003c\/li\u003e\n \u003cli\u003eAPPLICATION: Used in DC power system, ship electric power system, solar photovoltaic system, or other DC system.\u003c\/li\u003e\n \u003cli\u003eINSTALLATION: Screw clamp wires, 35mm DIN rail mount.\u003c\/li\u003e\n \u003c\/ul\u003e\n\n"}
[Australia - AusPower] - DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 10A

DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 10A

$137.00 AUD

DC Miniature Circuit Breaker, 2 Pole 1000V 10 Amp Isolator for Solar PV System, Thermal Magnetic Trip, DIN Rail Mount, Chtaixi DC Disconnect Switch C10 Chtaixi DC Miniature Circuit Breaker Warm Tips: Pay attention to polarity.Select wire size according to rated current. Magnetic Arc Extinguishing AC has a zero-crossing point, but DC does not, so...


More Info